C280-6 Offshore Generator Set

C280-6 Offshore Generator Set

The C280-6 generator set incorporates years of proven success of the 3600 engine with the latest technology in electronics. The result is a fully integrated solution that is ...
PDF Print SHARE

Engine Specifications

Minimum Rating
2320kV·A
Maximum Rating
2722kV·A
Emissions
IMO Tier 2 / EPA Marine Tier 2
Stroke
11.8in
Oil Change Interval
1000h
Fuel System
EUI
Displacement
6773in³
Bore
11in
Aspiration
Turbocharged-Aftercooled
Engine Control
Electronic ADEM™ A3
Generator Set Control
Generator Monitoring System (GMS)
Weight
91492lb

Dimensions

Height
107.6in
Length
293in
Width
71.6in

Capacity for Liquids

Cooling System - Engine
105gal (US)
Lube Oil System - Refill
229gal (US)

Standard Equipment:

Optional Equipment:

    Air Inlet System
    • 90° adapter and straight adapters for air inlet to turbocharger Air cleaners
    • Air cleaners with Cat dry paper filter elements (approximately 99.9% efficient at filtering SAE fine dust)
    • Soot filter
    Control System
    • 4-20 mA load feedback signal
    • Load sharing module
    • Direct rack module
    Cooling System
    • Separate Circuit Aftercooler (SCAC)
    • Customer water connections
    • Jacket water thermostats
    • AC/OC thermostats
    • Accessory module-mounted high volume expansion tank
    • Jacket water heater
    • Heat recovery connections and thermostats for use with water maker system
    • ANSI connection adapters
    Exhaust System
    • Exhaust manifold shields
    • Vertical or 30° outboard exhaust orientation options
    • Exhaust outlet expanders and weld flanges
    Fuel System
    • Manual fuel priming pump
    • Duplex primary fuel strainer
    • Flexible fuel hose connections
    Lube System
    • Dry engine-mounted sump system that gravity feeds into base assembly integral sump
    • Engine-mounted duplex oil filter
    • Intermittent air prelube
    • Continuous electric prelube
    • Redundant prelube with continuous electric prelube and intermittent air prelube backup
    • Oil pan drain valves
    • Electric continuous prelube pump
    • Lube oil heater
    Protection System
    • Wiring meets MCS requirements
    • Upgrade PLC monitor to industrial PC
    • Upgrades AC/OC, JW and start air pressure from contactors to transducers
    • Raw water/sea water pressure transducer
    • Modbus communication
    • Beacon and horn
    • Single engine remote display monitor
    • Emergency pump start signal
    • Cabinet cooler
    • Generator power monitoring
    • Remote relay panel
    • Turbocharger speed sensors
    • Cylinder pressure relief valve
    • Oil mist detector
    • Flywheel and damper guards
    Mounting System
    • Base aseembly
    • Vertically-restrained vibration isolators and weld plates
    Starting System
    • Single turbine air starters
    • Boost control valve for extremely cold ambient conditions
    • Air start pressure reducing valves
    General
    • Torsional couplings
    • Mounting groups for engine, generator, and base
    • Accessory module to mount attachments such as the expansion tank, heat exchanger, instrument panel and engine controls, annunciator panel, alarm and shutdown contactors, fuel strainer
    • Flywheel
    • Engine barring device options:
    • One-year storage preservation
    • Oceanic transportation shipping protection (shrink wrap and tarp)
    • Engine testing — certified dynamometer test, fuel consumption test, rated speed performance test, overload test, minimum power setting, peak firing pressure test, turbo work cert and crankshaft work cert
    • Standard and project-specific witness testing
    • Spare parts kit
    Literature
    • Project-specific installation drawings
    • Electrical schematics and P&ID drawings