C18 Generator Set

C18 Generator Set

360° Exterior View

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

PDF Print SHARE

Generator Set Specifications

Minimum Rating
550 kVA
Maximum Rating
715 kVA
Emissions/Fuel Strategy
Low Fuel Consumption, China Nonroad III Emission Standards
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby, Prime

Engine Specifications

Engine Model
C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore
5.71in
Stroke
7.2in
Displacement
1106.36in³
Compression Ratio
14.5:1
Aspiration
Air to Air Aftercooled
Fuel System
Electronic unit injection
Governor Type
Ademâ„¢A4

Generator Set Dimensions

Length - Maximum
162.4in
Width - Maximum
78.3in
Height - Maximum
75in

Standard Equipment:

Optional Equipment:

    Air Inlet System
    • Single element air cleaner
    • Dual element air cleaner
    Circuit Breakers
    • 3 Pole (IEC-100% rated) circuit breakers - Package mounted
    • 4 Pole (IEC-100% rated) circuit breakers - Package mounted
    • 3 Pole (IEC-100% rated) circuit breakers - Motorised
    • 4 Pole (IEC-100% rated) circuit breakers - Motorised
    • Circuit breaker (IEC) auxiliary contacts
    • Shunt trip for IEC breaker
    • Pad-lockable circuit breaker device
    • Power terminal strip
    Control System
    • EMCP 4.4
    • Volt free contact
    • Local alarm horn
    • Oil temperature displays
    • Protective devices: Earth fault relay - earth leageage ground fault relay - Overload shutdown via breaker - Low fuel level alarm - Low fuel level shutdown - high fuel level alarm - Fuel level sensor
    • Local alarm modules
    • Remote annunciator modules
    Cooling System
    • Radiator duct flange
    • Low coolant temperature alarm
    Enclosures
    • Sound attenuated enclosures
    Exhaust System
    • Engine mounted muffler
    • 10, 25 and 35 end in / end out Mufflers
    • 8 and 10 inch GP flanges
    • 8 and 10 inch elbow kits
    • Manifold and Turbocharger guard
    Fuel System
    • Integral - Duel wall fuel tank base
    • Manual fuel transfer pump
    • Fuel transfer system
    Generator And Attachments
    • Ingress protection
    • Permanent magnet excitation
    • Space heaters
    • A frame oversize generator
    • A frame CIP generator
    • LC frame generator
    • LC frame oversize generators
    • LC frame CIP generator
    Lube System
    • Manual sump pump
    Starting And Charging
    • 5 Amp battery charger
    • Battery disconnect switch
    • Jacket water heaters