G3520H

G3520H Gas Generator

THE RUNDOWN

Cat® Engine
  • Robust high speed block design provides prolonged life and lower owning and operating costs
  • High power density and efficiency
Cat G3520H Gas Engine
  • Robust high speed block design provides prolonged life and lower owning operationg costs
  • Designed for maximum performance on low pressure pipeline natural gas and hydrogen mixtures
  • Simple open chamber combustion system for reliability and fuel flexibility
  • Leading edge technology in ignition system and air/fuel ratio control for lower emission and engine efficiency
  • One electronic control module handles all engine functions: ignition, governing, air/fuel ratio control and engine protection
Generator Set Package
  • Genset reliability verified through torsional vibration, fuel consumption, oil consumption, transient performance, and endurance testing
  • Top tier electrical efficiency
  • Low maintenance and overhaul costs driven by low oil consumption, extended service intervals, and reduced downtime
  • Capable of ISO 8528-5 Class G1 transient performance with specified load steps
SR5 Generator
  • Designed to match performance and output characteristics of Caterpillar gas engines
  • Industry leading mechanical and electrical design
  • High efficiency
Generators
  • Designed to match performance and output characteristics of Cat engines
  • High-efficiency design
EMCP 4.3 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Applications
  • Cat generator sets are capable of maximizing power production opportunities in an extensive range of industries
  • Generator sets support up to 25% Hydrogen by volume capability, either direct from factory price list or retrofit kit.
EMCP 4 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirements
  • Expansion modules and site specific programming for specific customer requirements
Warranty
  • 12 months/unlimited hour warranty for continuous ratings
  • Extended service protection is available to provide extended coverage options
Emissions
  • Meets most worldwide emissions requirements down to 0.5 g/bhp-hr Nox level without aftertreatment
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Proven System
  • Field proven in a wide range of applications worldwide
  • Fully prototype tested
  • Certified torsional vibration analysis available
Financing
  • Caterpillar offers an array of financial products to help you succeed through financial service excellence
  • Options include loans, finance lease, operating lease, working capital, and revolving line of credit
  • Contact your local Cat dealer for availability in your region
Full Range of Attachments
  • Wide range of bolt-on system expansion attachments
  • Factory designed and tested
  • Flexible packaging options for easy and cost effective installation
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Generator Set Specifications
Continuous Rating2519 / 2500 ekW @ 1.0pf
Fuel TypeNatural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency45.30%
Frequency50 / 60 Hz
RPM1500
Frequency50/60 Hz
Engine Specifications
Engine ModelG3520H
Displacement5956in³
AspirationTA
Bore6.7in
Stroke8.5in
Compression Ratio12.1
Generator Set Dimensions
Length302in
Width86in
Height97in
Dry Weight - Genset54675lb
Standard Equipment

Control Panel

  • EMCP 4.3

Air Inlet

  • Two-element single-stage air cleaner with enclosure and service indicator

Circuit Breaker

  • LSI Long-Time, Short-Time, Instantaneous Annunciator
  • Rear-mounted
  • 5000A 3-Pole IEC Rated Circuit Breakers

Exhaust

  • Center section cooled turbocharger with Cat flanged outlet
  • Dry exhaust manifolds, insulated and shielded
  • Individual exhaust port and turbocharger outlet wired to Integrated Tmeperature Sensing Module (ITSM) with GECM providing alarms and shutdowns

Fuel system

  • Electronic fuel metering valve
  • Throttle plate, 24V DC actuator, controlled by GECM
  • Fuel system is sized for 31.5 to 47.2 MJ/NM3 dry pipeline natural gas with pressure of 10.2 to 34.5KPa to the engine fuel control valve

Ignition System

  • Electronic Ignition System (controlled by ADEM A4)
  • Individual Cylinder Detonation Sensitive Timing (DST)

Air Cleaner

  • Dual element single stage with enclosure and service indicator

Generator

  • Caterpillar's Digital Voltage Regulator (CDVR) with 3-phase sensing and KVAR/PF control
  • SR4B
  • Crankshaft Vibration Damper and Guard
  • Busbar connections
  • Paint- Caterpillar Yellow except rails gloss black
  • Winding temperature detectors
  • Operation and maintenance manuals
  • Parts book
  • Anti-condensation space heater
  • RH Service
  • SR5
  • Reactive droop

Govrerning System

  • ADEM A4 4-20mA (0-5VV) Speed Input

Starting

  • Dual electric starters

Cooling

  • Engine driven water pumps for jacket water and aftercooler
  • Jacket water and SCAC thermostats
  • ANSI/DN customer flange connections for JW inlet and outlet
  • No Radiator
  • No engine driven pumps

Crankcase Ventilation System

  • Positive crankcase ventilation

Mounting System

  • Rails

Controller

  • EMCP 4.3

Telematics

  • Ethernet

Alternator

  • Form wound
  • Permanent Magnet (PM) Excitation

Alternator attachments

  • Integrated Voltage Regulator (IVR)
Optional Equipment

Air Inlet

  • Mounting Brackets and Piping
  • Air cleaner with precleaner

Control Panel

  • 16 Point/32 Light Annunciator, Shipped Loose
  • Remote Communications Module (PL1000T, PL1000E)
  • Remote annuciator
  • Local PC Monitorring
  • Discrete I/O Module, 12 Digital Inputs, 8 'Form C' Relay
  • Cat Connect: Ehternet, Satellite, Cell Telematics
  • Engine failure relay
  • Local alarm module
  • Synchronizing module
  • Remote PC Monitorring

Air Cleaner

  • Off-engine dual element with enclosure and service indicator

Exhaust

  • Muffler and spark-arresting muffler with companion flanges
  • Flange
  • Flexible Fitting
  • Exhaust Expander

Generator

  • Bearing temperature detectors
  • Cable access box
  • Low voltage extension box
  • Manual voltage control
  • European bus bar
  • Generator air filter
  • Medium and high voltage generators and attachment

General

  • Digital diagnostic tool
  • Special paint order
  • Tool set
  • US AID Emblem

Starting/Charging

  • Battery with cables and rack (shipped loose)
  • 24V starting motors
  • 60A, 24V charging alternator (requires engine driven pumps)

Starting

  • Oversized batteries
  • Charging Alternator - 60A (requires engine driven pumps)
  • Battery charger - 20A
  • Jacket water heater

Cooling

  • Inlet/Outlet connections
  • Coolant level drain line with valves, fan with guard
  • JW & SCAC engine driven pumps
  • JW outlet connection (RH or LH)

Fuel System

  • Gas Knockdown Regulator
  • Fuel filter
  • Gas pressure regulator
  • Gas shutoff valve 24V, ETR (Energized-To-Run)
  • Gas Train (EU or NFPA/CSA version)
  • Hydrogen / Natural Gas blend
  • Gas Pressure Sensor
  • Double Shutoff Solenoid
  • Gas Knockdown Regulator

Lubrication System

  • Oil level regulator
  • Extended life oil tank

Crankcase Ventilation System

  • Explosion relief valve

Muffler

  • Industrial grade (15 dB)
  • Critical grade (25 dB)
  • Spark arresting

Mounting System

  • Spring vibration Isolators
  • Seismic rated vibration isolators

Controller attachments

  • Local annunciator module
  • Remote annunciator module
  • Discrete I/O module
  • Remote monitoring software

Telematics

  • Cellular
  • Satellite

Alternator Temperature rise (over 40°C ambient)

  • 105°C
  • 125°C

Alternator Output Voltage

  • 400V
  • 415V
  • 480V
  • 4160V
  • 6300V
  • 6600V
  • 6900V
  • 10500V
  • 11000V
  • 12400V
  • 13200V
  • 13800V

Alternator attachments

  • Digital Voltage Regulator (DVR)
  • Anti-condensation space heater
  • Neutral Ground
  • Current Transformer (CT)
  • Differential CT
  • Stator and bearing temperature monitoring and protection

Power termination

  • Busbar NEMA
  • Busbar IEC
  • Circuit breaker

Circuit breaker

  • Frame Mounting
  • MP- Frame 6 Pole Bottom Cable Entry
  • 4000/5000A Neutral Current Transformer Automatic Selection
  • No UV trip or package mounted CB Wiring
  • 5000A
  • IEC
  • UL
  • 3-pole
  • 4-pole
  • Manually operated
  • Electrically operated

Trip Unit

  • LSI
  • LSI-G
  • LSIG-P

Ancilliary Equipment

  • Automatic transfer switch (ATS)
  • Paralleling switchgear
  • Paralleling controls

Certifications

  • EU & GB Declaration of Conformity
  • Eurasian Conformity (EAC)

Grid Code Compliance

  • 50 Hz: Germany, Great Britain, Belgium, Romania, Italy, Ireland, Poland, Netherlands, Spain, France, and European Standard
  • Belgium: Synergrid C10/11 ed.2.2
  • European Standard: EN 50549-2
  • France: Arrêté du 9 juin 2020
  • Germany Medium Voltage: VDE-AR-N-4110
  • Great Britain: G99, Issue 2
  • Ireland: Distribution Code Version 8.0
  • Italy: CEI 0-16;V3 (2024-01)
  • Netherlands: Netcode Elektriciteit
  • Poland: Wymogi ogólnego stosowania 2018
  • Romania Type B: ANRE Ord. 72/2017, Ord. 214/2018
  • Spain: TED/749/2020

Extended service terms

  • 2 year
  • 3 year
  • 5 year
  • 10 year

Extended service coverage

  • Silver
  • Gold
  • Platinum
  • Platinum plus