G3516 with FAST RESPONSE

G3516 1500kW Gas Generator Set

THE RUNDOWN

Cat G3516 Gas Engine
  • Robust high speed block design provides prolonged life and lower owning operationg costs
  • Designed for maximum performance on low pressure pipeline natural gas and hydrogen blends
  • Simple open chamber combustion system for reliability and fuel flexibility
  • Leading edge technology in ignition system and air/fuel ratio control for lower emission and engine efficiency
  • One electronic control module handles all engine functions: ignition, governing, air/fuel ratio control and engine protection
CAT G3516 Gas Engine
SR5 Generator
  • Designed to match performance and output characteristics of Caterpillar gas engines
  • Industry leading mechanical and electrical design
  • High efficiency
SR5 Generator
Cat ECS 100 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cat ECS 100 Control Panel
Cooling System
  • Designed to operate in standard ambient temperatures up to 43°C (110°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Emissions
  • EPA Certified for use in Emergency and Non-Emergency applications
  • Additional a NOx selectable genset is available to meets most worldwide emissions requirements down to 0.5 g/bhp-hr NOx level without aftertreatment
Emissions
Proven System
  • Field proven in a wide range of applications worldwide
  • Fully prototype tested
  • Certified torsional vibration analysis available
Proven System
Full Range of Attachments
  • Wide range of bolt-on system expansion attachments
  • Factory designed and tested
  • Flexible packaging options for easy and cost effective installation
Full Range of Attachments
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Worldwide Product Support
Generator Set Specifications
Gas Standby Rating1500 ekW @ 0.8pf
Fuel TypeNatural Gas, Hydrogen Blend (up to 5%)
Emissions/Fuel StrategyU.S. EPA Stationary Non-Emergency Certified
RPM1800 rpm
Frequency60 Hz
Compression Ratio11.5
Engine Specifications
Engine ModelG3516
Displacement4765in³
AspirationTA
Bore6.7in
Stroke8.5in
Generator Set Dimensions
Length275.6in
Width92.3in
Height128.5in
Weight40384lb
Standard Equipment

Air Inlet

  • Two-element single-stage air cleaner with enclosure and service indicator

Control Panel

  • Cat ECS 100

Exhaust

  • Dry exhaust manifolds, insulated and shielded
  • Individual exhaust port and turbocharger outlet wired to integrated temperature sensing module (ITSM) with GCEM providing alarms and shutdowns
  • Cat-flanged face outlet on turbocharger

Fuel System

  • Fuel system is sized for 31.5 to 47.2 MJ/NM3 dry pipeline natural gas with pressure of 10.2 to 34.5KPa to the engine fuel control valve
  • Throttle plate, 24V DC actuator, controlled by GECM
  • Gas pressure regulator
  • 24V DC energized-to-run (ETR) gas shutoff valve
  • Engine-installed electronic control valve

Air Cleaner

  • Dual element single stage with enclosure and service indicator

General

  • Crankshaft vibration damper and guard
  • Paint- Caterpillar Yellow with high gloss black rails and radiator
  • RH Service
  • Operation and maintenance manuals
  • Parts book

Generator

  • Permanent Magnet Excitation
  • Anti-condensation space heater
  • Winding temperature detectors
  • NEMA Class H insulation
  • Integrated voltage regulator (IVR)
  • SR5

Starting/Charging

  • Electric Starter
  • 24V starting motors
  • Jacket water heater
  • Battery with cables and rack (shipped loose)

Governing System

  • ADEM A4

Starting

  • Dual electric starters

Ignition System

  • Individual Cylinder Detonation Sensitive Timing (DST)
  • Electronic Ignition System (controlled by ADEM A4)

Cooling

  • Jacket water and SCAC engine-driven pumps
  • Jacket water and SCAC thermostats
  • Standard Ambient Radiator
  • JW & SCAC engine driven pumps

Mounting System

  • Rails

Controller

  • Cat ECS 100

Telematics

  • Ethernet

Alternator

  • Random wound
  • Permanent Magnet (PM) Excitation

Alternator attachments

  • Integrated Voltage Regulator (IVR)

Power Termination

  • Busbar NEMA

Certifications

  • ICES for Canada
Optional Equipment

Air Inlet

  • Air cleaner with precleaner

Control Panel

  • Remote annunciator
  • Local alarm module
  • Remote PC monitoring
  • Engine failure relay
  • Local PC monitoring
  • EMCP 4.4

Circuit Breakers

  • S LSI, G LSIG, P LSIG-P, 4th Digit Type
  • 100% rated, 3-pole (UL/CSA/IEC) 5th Digit Rating
  • 3-pole (IEC 947-2 rated)
  • 2000A, 2500A, 3000A 3 Pole, UL-100% Rated Masterpact Circuit Breakers
  • 1600A, 2000A 3 Pole, UL-100% Rated R-Frame Circuit Breakers
  • Frame mounting

Exhaust

  • 305 mm (12 in.) muffler
  • 305 mm (12 in.) flange
  • 305mm (12 in) spark arresting muffler
  • 305 mm (12in.) elbow
  • 18, 25 dBA Attenuation

General

  • Digital diagnostic tool

Generator

  • European bus bars
  • Bearing temperature detectors
  • Low voltage extension box
  • Generator air filter
  • Cable access box

Starting/Charging

  • 45A, 24V charging alternator (requires engine driven pumps)
  • 20A, 24VDC battery charger

Grid Code Compliance

  • 60 Hz: USA

Starting

  • Standard batteries
  • Charging Alternator - 50A
  • Battery charger - 20A
  • Battery charger - 40A
  • Battery charger - 50A
  • Jacket water heater

Cooling

  • Coolant level drain line with valves, fan with guard
  • Package mounted radiator
  • No Radiator

Fuel System

  • 3, 0-100 kPag, 4-20mA gas train pressure sensors
  • Gas Train (NFPA/CSA)
  • Gas Pressure Sensor
  • Shutoff Solenoid
  • Double Shutoff Solenoid
  • Gas Knockdown Regulator

Lubrication System

  • Oil level regulator
  • Electric pre-lube pump

Crankcase Ventilation System

  • Positive crankcase ventilation
  • Explosion relief valve

Muffler

  • Industrial grade (15 dB)
  • Residential grade (18 dB)
  • Spark arresting

Mounting System

  • Rubber
  • Spring vibration Isolators
  • Seismic rated vibration isolators

Controller

  • Cat ECS 200

Controller attachments

  • Remote annunciator module
  • Remote HMI Panel
  • Load Share module
  • Discrete I/O module
  • CAN2 wiring
  • Remote monitoring software

Telematics

  • Cellular

Alternator

  • Form wound

Alternator Temperature rise (over 40°C ambient)

  • 80°C
  • 105°C
  • 125°C
  • 150°C

Alternator Output Voltage

  • 440V
  • 480V
  • 600V
  • 4160V
  • 12400V
  • 13200V
  • 13800V

Alternator attachments

  • Anti-condensation space heater
  • Current Transformer (CT)
  • Differential CT
  • Stator and bearing temperature monitoring and protection

Power termination

  • Circuit breaker

Circuit breaker

  • 1600A
  • 2000A
  • 2500A
  • 3000A
  • 4000A
  • 5000A
  • UL
  • 3-pole
  • Manually operated
  • Electrically operated

Trip Unit

  • LSI
  • LSI-G
  • LSI-P
  • LSIG-P
  • UV

Ancilliary Equipment

  • Automatic transfer switch (ATS)
  • Paralleling switchgear
  • Paralleling controls

Certifications

  • UL 2200 Listed

Extended service terms

  • 2 year
  • 3 year
  • 5 year
  • 10 year

Extended service coverage

  • Silver
  • Gold
  • Platinum
  • Platinum plus