DE65 GC Generator Set (50 Hz)
THE RUNDOWN
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
GCCP 1.1 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Designed to operate in standard ambient temperatures up to 50°C (122°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
Designed to meet applicable global standards including ISO 8528, ISO 3046 and IEC 60034-1, with CE, UKCA and EAC conformity available depending on configuration and market.
One Safe Source
- Components used in the generator set are selected based on seamless design integration to provide the optimum performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Generator Set Specifications
| Standby Rating | 65 kVA |
| Maximum Rating | 65.0 kVA |
| Minimum Rating | 65.0 kVA |
| Frequency | 50 Hz |
| Prime Power Rating | 60 kVA |
| Emissions/Fuel Strategy | Low BSFC |
| Voltage | 380 to 415 Volts |
| Speed | 1500 rpm |
| Duty Cycle | Standby |
Engine Specifications
| Engine Model | Cat® C3.3, In-line 3, 4-cycle diesel |
| Bore | 4.1in |
| Stroke | 5in |
| Displacement | 201.4in³ |
| Compression Ratio | 17.25:1 |
| Aspiration | Turbocharged |
| Fuel System | Inline |
| Governor Type | Mechanical |
Generator Set Dimensions
| Length - Maximum | 89.7in |
| Width - Maximum | 35.4in |
| Height - Maximum | 52in |
| Dry Weight - Genset (maximum) | 2273lb |
Standard Equipment
Engine
- C3.3, Inline 3 cylinder, 4 stroke diesel
Genset Control
- GCCP 1.1
Governor
- Mechanical governor
Alternator
- Standard alternator
Fuel Storage
Base Type
- Skid base
Enclosure
- Cat GC enclosure
Air, Cooling & Exhaust
Air Inlet
- Standard air filter
General
- Engine and alternator pre-paint, Caterpillar yellow
Telematics
- Cat® Product Link™ PL444 cellular
Optional Equipment
Certification
- CE & UKCA
- CIS
Alternator Requirements
- Space heater
Auxiliary Supply Voltage
- 120V
Fuel Storage
- Single wall tank without containment
- Single wall tank with containment
- Fuel level alarm
- Integral dual wall tank
- Low fuel shutdown
Genset Control
- Battery charger
- Volt free contacts for common alarm
- Audible alarm
- Panel mounted audible alarm
- Earth fault
- Earth leakage
- USB to RS485 Communications device
- Emergency stop with key
- Battery
- Standby Pack (Smart Jacket water heater, Battery charger)
- Coolant heater
- Low coolant level shutdown
Circuit breaker
- 3 Pole Circuit breaker 63A
- 3 Pole Circuit breaker 80A
- 3 Pole Circuit breaker 100A
- 3 Pole Circuit breaker 125A
- 3 Pole Circuit breaker 160A
- 3 Pole Circuit breaker 200A
- 4 Pole Circuit breaker 80A
- 4 Pole Circuit breaker 63A
- 4 Pole Circuit breaker 100A
- 4 Pole Circuit breaker 125A
- 4 Pole Circuit breaker 160A
- 4 Pole Circuit breaker 200A
- Circuit breaker padlock
- Neutral earth link
- Overload via alarm switch on breaker
Testing & Packaging
- PGS Test report @ 1.0 power factor
- PGS Test report @ 0.8 power factor
Package
- Open Set