D60 GC

D60 GC Generator Set

THE RUNDOWN

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
M-Frame Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
GCCP 1.2 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • UL 2200 Listed
  • ULC Certification Available
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Generator Set Specifications
Maximum Rating60 ekW
Minimum Rating60 ekW
Emissions/Fuel StrategyU.S. EPA Cert., Tier 3
Voltage208 to 600 Volts
Frequency60 Hz
Speed1800 rpm
Duty CycleStandby
Engine Specifications
Engine ModelC4.4, In-line 4, 4-cycle diesel
Bore4.1in
Stroke5in
Displacement269in
Compression Ratio16.7:1
AspirationTurbocharged
Fuel SystemElectronic (adjustable)
Governor TypeMechanical, ADEM™A4
Generator Set Dimensions
Length - Maximum77.2in
Width - Maximum43.3in
Height - Maximum48in
Dry Weight - Genset (maximum)2054lb
Standard Equipment

Certificates

  • IBC seismic and wind Certifications

Circuit breakers

  • Breakers (100% UL rated)
  • 3-Pole 100% rated
  • Second circuit breaker box
  • Power terminal strip

Charging System

  • NFPA battery charger UL10A 120VAC

Air Inlet System

  • Air cleaner
  • Cartridge type air filter

Control Panel

  • GCCP 1.2 Control panel

Exhaust System

  • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose

Fuel System

  • Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank

Control Panels

  • WSS1 Low coolant level shut down
  • FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected
  • NFPA110 bundle includes:
  • WCA1 Low coolant temperature alarm
  • A Coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
  • PBC10NU NFPA battery charger
  • Oil temperature gauge and sender
  • PAA1 Panel mounted audible alarm
  • Ground fault relay
  • Remote E-stop button
  • Remote annunciator module
  • Audible alarm
  • Volt free contacts genset run and common alarm
  • Discrete I/O module
  • Overload shutdown via breaker
  • Low coolant temperature alarm
  • Protective devices:
  • Fuel level reading
  • Low coolant level shutdown

Cooling System

  • Coolant drain line with valve
  • Fan drive, battery charging alternator drive
  • Caterpillar extended life coolant
  • Radiator and cooling fan with guards
  • Radiator stone guard

Generator

  • 12 Leads

Governing System

  • Mechanical and electrical governing system - model dependent

Lube System

  • Oil drain line with valve
  • Lubricating oil

General

  • Engine and alternator pre-paint, Caterpillar yellow

Starting/Charging System

  • Batteries
  • 24V battery with rack and cables
Optional Equipment

Certificates

  • IBC seismic and wind Certifications

Alternator System

  • R Frame auxilliary winding

Air Inlet System

  • Cartridge type air filter

Charging System

  • NFPA battery charger UL10A 120VAC

Circuit breakers

  • Breakers (100% UL rated)
  • 3-Pole 100% rated
  • Second circuit breaker box
  • Power terminal strip

Control Panels

  • NFPA110 bundle includes: FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low coolant level shut down - WCA1 Low coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA battery charger - A Coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
  • Ground fault relay
  • Remote E-stop button
  • Volt free contacts genset run and common alarm
  • Oil temperature gauge and sender
  • Audible alarm
  • Remote annunciator module
  • Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
  • Discrete I/O module

Cooling System

  • Radiator transition flange

Enclosures

  • Sound attenuated enclosure, Level 1
  • External emergency stop
  • Sound attenuated Level 2 Enclosure (White)
  • Panel viewing window

Exhaust System

  • 10, 25 and 35 dBA silencer systems
  • Overhead silencer mounting kit

Fuel System

  • Emergency vent pipe
  • Tank riser
  • 5 Gallon spill containment
  • 209 and 394 gallon sub-base fuel tanks
  • 5 Gallon fill containment

Heating Elements

  • Battery heater
  • Jacket water heater
  • Coolant heater
  • Anti-condensation heater
  • Wiring for canopy space heater
  • Lube oil sump heater

Generators

  • Permanent magnet excitation (PMG) generator
  • Cat Alternator

Mounting System

  • Seismic vibration isolators

Tests

  • 4 Hour factory test
  • Generator test report
  • PGS Test report @ 0.8 power factor
  • PGS Test report @ 1.0 power factor