C280-16 Generator Set (Medium Speed)
THE RUNDOWN
Cat Diesel Engine
Cat® Diesel Engine
- Designed and optimized for Marine EPA Tier 4 or IMO Tier 2 emissions
- Reliable, rugged, durable design
Cat® Diesel Engine
Generator
Alternators
- Superior motor starting capability minimizes need for oversizing generator
- Matched to the performance and output characteristics of Cat engines
Alternators
Generator Set Package
- Fully prototype tested with certified torsional vibration analysis available
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Full Range of Attachments
Cat Generator Set Monitoring System (GSM)
- Simple user friendly interface and navigation
- Provides protection, monitoring, and control of the diesel generator set
- Redundant shutdown protection
- 10 inch (254 mm) color monitor to display all engine parameters and alarm annunciation
- Annunciation of all engine shutdowns, alarms, and status points
- Start/prelube control switch, fuel control switch and emergency stop buttons
- Speed control switch with automatic changing to ball head control when a governor failure occurs, if ball head control is available
- Contacts are available for customer use
- Selection of local/remote control of engine
- Selection of idle/rated control of engine
- Equipped for remote communication
- Four 4-20mA outputs (programmable)
- Relay contact signals to the remote monitoring system (summary shutdown, summary alarm, local operation/remote, engine running, PLC failure, fuel control and idle/rated)
Generator Set Specifications
| Maximum Rating | 4840 ekW (60Hz), 6500 kVA (50Hz) |
| Minimum Rating | 4400 ekW (60Hz), 5875 kVA (50Hz) |
| Emissions/Fuel Strategy | EPA Tier 4 Final, IMO Tier 2 |
| Frequency | 50 / 60 Hz |
| Speed | 900 / 1000 rpm |
| Duty Cycle | Prime, Continuous |
Engine Specifications
| Engine Model | C280-16, V-16,4-Stroke Water-Cooled Diesel |
| Bore | 11in |
| Stroke | 11.8in |
| Displacement | 18032in³ |
| Compression Ratio | 13:01 |
| Aspiration | TA |
| Fuel System | Direct unit injection |
| Governor Type | Generator Set Monitoring System (GMS) |
Generator Set Dimensions
| Length - Maximum | 404in |
| Width - Maximum | 99.62in |
| Height - Maximum | 156.6in |
| Dry Weight - Genset (maximum) | 141840lb |
Standard Equipment
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
- Air inlet shutoff
- Turbocharger, watercooled, engine oil lubricated
- Breather, crankcase, top-mounted
- Aftercooler, fresh water, corrosion resistant coated (air side)
- Air cleaner
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Air Inlet System
Cooling System
- Three-bundle oil cooler
- Jacket water thermostats
- Front Mounted turbos
- Engine coolant water drains
- Water temperature regulator
Exhaust System
- Dry, gas tight, exhaust manifold
- 457 mm (18 in) Cat bolt pattern
- Includes adapter, flexible exhaust fitting
Fuel System
- Simplex or duplex
Generator System
- Custom generator per generator data sheet completed by dealer
Governor System
- UG Actuator
Lube System
- Wet oil sump. Includes engine-driven main lubrication and oil pumps, oil lines and oil pan
- Centrifugal oil filters with single shutoff
- Oil filler and dipstick
- Service Side Engine mounted on Cylinder Block Inspection Covers
- Crankcase explosion relief valves
- Oil pressure regulating valve
Mounting System
- Damper, torsional vibration
- Engine and generator mounting
Starting / Charging System
- Line group for single point custom connection
- Two Motors, engine mounted at rear, on left side
- Vane type air starter
- Air silencer
General:
- Gear driven pumps: Fuel/oil/jacket water/Aftercooler/Oil cooler water
- Paint, Caterpillar yellow
Optional Equipment
Air Inlet System
- Air inlet adapter
- Vertical support bracket
- Air cleaner louver assembly
- Boost control valve
- Soot filter
- Heavy duty air cleaner
Cooling System
- Auxiliary water pump
- Heat exchanger for single circuit
- Expansion tank
- Cooling system aids
- Heating aids
Exhaust System
- Flexible exhaust Fittings
- Weld flange and related hardware
Fuel System
- Duplex primary fuel strainer
- Fuel system connections
- Fuel priming pump
Generator System
- Winding temperature detectors
- Anti-condensation space heaters
- 3 Phase, Six Leads, WYE
- Class F insulation
- Busbar connections
Governor System
- Electronic/actuators
- EGB actuator
- Digital programmers
- Battery backup/power supply
- 230 UA
- 723 Plus
Lube System
- Oil pan drain valve
- Lube ANSI Adapter (Emergency connection)
Mounting System
- Spring type vibration isolators
- Vertically Restrained
- Non-vertically Restrained
- Isolator
Starting / Charging System
- Compressed air flex hose
- Turbine type air starters
- Pressure reducing valve
- Redundant air starters
General:
- Custom paint colors