C175-16 (60 Hz)

C175-16 Generator Set

THE RUNDOWN

Cat® Diesel Engine
  • Rugged, durable design with reliable performance proven in thousands of applications worldwide
  • Certified alternative fuels including Hydrotreated Vegetable Oil (HVO), Renewable Diesel (RD) and Hydrotreated Renewable Diesel (HRD) which meet EN 15940 or ASTM D975 can be used or blended with EN 590 diesel
Cat Generator Set Package
  • Accepts 100% block load in one step
  • Meets NFPA 110 loading requirements
  • Conforms to ISO 8528-5 G3 load acceptance requirements
  • Reliability verified through torsional vibration, fuel consumption, oil consumption, transient performance, and endurance testing
Alternators
  • Superior motor starting capability minimizes need for oversizing generator
  • Designed to match performance and output characteristics of Cat diesel engines
Cooling System
  • Cooling systems are available to operate in ambient temperatures up to 50°C (122°F)
  • Tested to ensure proper generator set cooling
Cat ECS Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirements
  • Expansion modules and site specific programming for specific customer requirements
  • Graphical touchscreen display
  • Easily upgradeable
Warranty
  • 24 months/1000-hour warranty for Standby and Mission Critical ratings
  • 12 months/unlimited hour warranty for Prime and Continuous ratings
  • 12 months/unlimited hour warranty for Prime-DCP ratings
  • Extended service protection is available to provide extended coverage options
World Wide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Financing
  • Caterpillar offers an array of financial products to help you succeed through financial service excellence
  • Options include loans, finance lease, operating lease, working capital, and revolving line of credit
  • Contact your local Cat dealer for availability in your region
Generator Set Specifications
Standby Rating3365(no fan)/3250/3100(no fan)/3000 ekW
Prime Power Rating3115(no fan)/3000/2825(no fan)/2725 ekW
Emissions/Fuel StrategyLow Fuel, Tier 2
Voltage480 to 13800 Volts
Frequency60 Hz
Speed1800 RPM
Duty CycleStandby, Mission Critical, Prime, Continuous
Maximum Rating3365 ekW
Minimum Rating2500 ekW
Engine Specifications
Engine ModelC175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel
Bore6.89in
Stroke8.66in
Displacement6456.31in³
Compression Ratio16.7:1
AspirationTurbo Aftercooled
Fuel SystemCommon Rail
Governor TypeADEM� A4
Generator Set Dimensions
Length - Minimum250.9in
Length - Maximum330.6in
Width - Minimum82.7in
Width - Maximum124.3in
Height - Minimum86.9in
Height - Maximum134.2in
Dry Weight - Genset (minimum)42750lb
Dry Weight - Genset (maximum)57774lb
Standard Equipment

Air Inlet System

  • 4 x Single element canister with service indicator(s).

Control Panel

  • 2 Programmable relay outputs (Form C)
  • Low coolant level
  • Over/under voltage
  • Coolant temperature
  • Serial annunciator module data link
  • Alarm acknowledge
  • Text alarm/event descriptions
  • Volts (L-L & L-N)
  • Reverse power
  • Over/under frequency
  • Environmental sealed front face
  • Programmable protective relaying functions
  • Speed adjust
  • Generator phase sequence
  • Low coolant temperature
  • Generator mounted - rear facing
  • Overspeed
  • Controls
  • Frequency (Hz)
  • Engine cycle crank
  • Engine cool-down timer
  • Warning/shutdown Indicators:
  • Lamp test
  • 2 Programmable digital outputs
  • 6 Programmable digital inputs
  • High coolant temperature
  • Customer data link (Modbus RTU)
  • Auto/start/stop control
  • Emergency stop pushbutton
  • RPM
  • Digital Indicators
  • Communications
  • Accessory module data link
  • Oil pressure (psi, kPa or bar)
  • Low oil pressure
  • Overcurrent
  • Emergency stop
  • 24 Volt DC operation
  • 4 Programmable relay outputs (Form A)
  • Failure to start (overcrank)
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Power factor (per phase & average)
  • Operating hours
  • DC volts
  • Amps (per phase & average)
  • Cat ECS 100
  • Reverse reactive power

Exhaust System

  • Bolted flange, with bellow for each turbo
  • Exhaust flange outlet

Fuel System

  • Engine mounted filters #REF!
  • Filters x 3
  • 10 Micron spin on yype
  • Secondary/tertiary fuel filters
  • 4 Micron spin on type
  • Primary fuel filter water/fuel water separator

Generators and Attachments

  • Right side extension box, bottom cable entry
  • IEC platinum stator RTDs
  • Reactive droop capability
  • 3 Phase voltage sensing
  • (MV) Busbar connections, right side extension box, bottom cable entry
  • Class F temperature rise at 40C ambient
  • Anti-condensation space heater
  • NEMA Class H insulation
  • 6 Leads
  • Class H temperature rise at 40C ambient
  • Voltage regulator
  • Exciter diode monitor
  • Form wound
  • RFI suppression
  • (LV) Busbar connections, top/center mounted, top cable entry
  • 3 Phase brushless
  • 60 Hz models: NEMA standard hole pattern
  • Permanent magnet excitation (PMG)
  • Min / max exciter limiter
  • Salient pole

Governing System

  • Redundant shutdown (Overspeed protection through a duplicate speed sensing system)
  • ADEM A4

Lube System

  • Oil filter, filler and dipstick
  • Integral lube Oil cooler
  • Oil drain lines and valve
  • Fumes disposal
  • Lubricating oil
  • Prelube - required with prime, continuous, and standby
  • Gear type lube oil pump

Mounting Systems

  • Rails - Engine/generator
  • Rubber anti-vibration mounts - shipped loose
  • Dual 24 volt electric starting motors
  • Battery disconnect switch
  • Batteries and battery rack w/cables

Power Termination

  • Busbar

Service Instructions

  • Two PM inspections

General

  • Paint - Caterpillar yellow with high gloss black rails & radiator
  • SAE standard rotation
  • LH Service
  • Flywheel and flywheel housing-SAE No. 00
Optional Equipment

Air Inlet System

  • Air inlet adapters
  • Dual element air cleaner
  • Single element air cleaner
  • Air inlet protection

Control Panel

  • Package mounted radiator
  • Automatically selected ground
  • Customer AC-DC connection mounting location - LV/MV
  • Load share governor
  • EMCP 4.4
  • E-Stop
  • Frame boxes
  • Annunciator modules
  • Load share module / auxiliary plate and auxiliary box (LV)
  • Fuel cooler
  • Controller mounting location - LV/MV
  • Modbus monitoring of packages
  • Customer interface options
  • EMCP 4.4 optional harness
  • Controller voltage and current sensing groups
  • Remote radiators
  • Generator harness
  • Interconnect harness
  • Speed adjust
  • Controller and MV and HV power connection locations
  • Raise lower switch

Crankcase Systems

  • Explosive relief valves
  • Crankcase ventilation system

Exhaust System

  • Mufflers
  • Exhaust support group
  • Weld flanges
  • Exhaust collectors/manifold
  • Front housing - Prime or continuous
  • Front housing - Standby or mission critical
  • Aftercooler drain

Fuel System

  • Primary fuel filter

Generators and Attachments

  • Low voltage - 1800 and 3000 Frames - 60 Hz, 3 phase, 1800 rpm, FW, PM, No of leads=6, Pitch 0.6667
  • Medium voltage - 1800 and 3000 Frames - 60 Hz, 3 phase, 1800 rpm, FW, PM, No of leads=6, Pitch 0.6667
  • Conversion GP - Top cable entry
  • Low voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
  • Differential current transformers
  • Space heater kit
  • Medium voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
  • Thermostat for space heater
  • Generator air intake

Instrumentation

  • Pyrometer and thermocouples

Lube System

  • Drain group oil pans
  • Oil filters
  • Lube oil heater
  • Electric prelube pumps
  • Lubricating oil

Mounting Systems

  • IBC vibration isolators - Shipped loose
  • Spring type linear vibration isolators
  • Rubber anti-vibration mounts

Power Connections

  • Low voltage connection cable
  • Center post busbarss (LV)
  • 1800 Frame generator side / rear mounted busbars (MV)
  • Enclosures - Control packaging (LV)
  • Paralleling circuit breakers
  • 1800 Frame generators Circuit breaker
  • Neutral ground (LV)
  • Neutral ground (MV)
  • Cable entry options (LV)
  • Cable entry options (MV)
  • Masterpack breakers
  • Power connection covers (LV)
  • Harnesses (Breaker)
  • Masterpack breaker connections
  • Side/rear mounted busbars (LV)

Special Tests / Reports

  • IBC seismic Certification
  • Special test charge - Engine only
  • PGS Test report @ 0.8 power factor
  • Genset fuel consumption test
  • Standard genset TVA (Torsional Vibration Analysis) report
  • PGS Test report @ 1.0 power factor
  • OSCOSH1 seismic Certification
  • Custom generator TVA report
  • Generator test report
  • Standard engine test charge

Starting / Charging System

  • Heavy duty battery sets with rack
  • Charging alternators - Dry
  • Air pressure regulator
  • Starter location covers
  • 24 Volt power distribution box
  • 24 Volt electric starting motor
  • 35 Amp Battery chargers
  • 24 Volt battery set - Dry
  • 20 Amp Battery chargers
  • Jacket water heaters
  • 50 Amp Battery chargers
  • Air starting motor
  • Jacket water heater wiring groups

General

  • Special paint colors
  • Control GP - air powered bar group
  • Barring group manual
  • Service tools - Engine barring group
  • Engine barring air powered