3516E (60 Hz)

3516E Low Voltage Generator Set

THE RUNDOWN

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
Cat ECS Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 50�C (122�F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • UL 2200 Listed
  • CSA
  • IBC seismic certification
  • OSHPD pre-approval
One Safe Source
  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Generator Set Specifications
Standby Rating2750 ekW
Prime Power Rating2500 ekW
Emissions/Fuel StrategyTier 2, Low NOx
Voltage416 to 13,800 Volts
Frequency60 Hz
Speed1800 rpm
Duty CycleStandby, Mission Critical, Prime
Maximum Rating2750 ekW
Minimum Rating2500 ekW
Engine Specifications
Engine Model3516E, V-16, 4-Stroke, Water-Cooled Diesel
Bore6.69in
Stroke8.47in
Displacement4765in³
Compression Ratio14.7:1
AspirationATAAC
Fuel SystemEUI
Governor TypeAdem™ A5
Generator Set Dimensions
Length - Maximum311.9in
Width - Maximum104.0in
Height - Maximum131.6in
Dry Weight - Genset (maximum)40750lb
Standard Equipment

Air Inlet System

  • Air cleaner

Air Cleaner

  • Single element with service indicator

Starting

  • Heavy duty electric starter(s)

Exhaust

  • Exhaust flange outlet

Fuel

  • Primary fuel filter with integral water separator
  • Fuel priming pump

Cooling

  • Package mounted radiator
  • ATAAC
  • Standard Ambient Radiator

Generator

  • IP23 Protection
  • Matched to the performance and output characteristics of Cat engines

Crankcase Ventilation System

  • Non filtered crankcase ventilation

Starting/Charging

  • Heavy duty starting system
  • Charging alternator

Controller

  • Cat ECS 100

Alternator

  • Form wound
  • Permanent Magnet Excitation

Control Panel

  • 6 Programmable digital inputs
  • Programmable protective relaying functions:
  • Low oil pressure
  • Environmental sealed front face
  • Volts (L-L & L-N)
  • Emergency stop pushbutton
  • Serial annunciator module data link
  • Reverse power (kW) (32)
  • Engine cycle crank
  • Lamp test
  • Over/under frequency (81 o/u)
  • kW-hr (total)
  • Speed adjust
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Engine cool-down timer
  • Overcurrent (50/51)
  • Reverse reactive power (kVAr) (32RV)
  • kW (per phase, average & percent)
  • kVAr-hr (total)
  • Generator phase sequence
  • Oil pressure (psi, kPa or bar)
  • Low coolant temperature
  • Amps (per phase & average)
  • Generator mounted - rear facing
  • Over/under voltage (27/59)
  • Low coolant level
  • Accessory module data link
  • kVAr (per phase, average & percent)
  • Cat ECS controller includes:
  • Failure to start (overcrank)
  • 2 Programmable relay outputs (Form C)
  • Cat ECS 100
  • Overspeed
  • 2 Programmable digital outputs
  • DC volts
  • Frequency (Hz)
  • High coolant temperature
  • Warning/shutdown with common LED indication of shutdowns for:
  • Operating hours
  • 4 Programmable relay outputs (Form A)
  • Coolant temperature
  • Power factor (per phase & average)
  • Digital indication for:
  • Panel lights
  • Text alarm/event descriptions
  • Controls:
  • 24 Volt DC operation
  • Alarm acknowledge
  • Customer data link (Modbus RTU)
  • kVA (per phase, average & percent)

Telematics

  • Ethernet

Cooling System

  • Caterpillar extended life coolant
  • Coolant drain line with valve
  • Coolant level sensors
  • JWAC
  • Radiator fan and fan drive
  • Fan and belt guards

Exhaust System

  • Dry exhaust manifold
  • Flanged faced outlet(s)

Fuel System

  • Secondary fuel filters
  • Flexible fuel lines - shipped loose
  • Fuel cooler; not included with packages without radiator
  • Fuel priming pump

Generators and Attachments

  • Permanent magnet excitation (PMG)
  • Anti-condensation space heater
  • Right side extension terminal box, busbar connections, top mounted, bottom cable entry
  • 6 Lead
  • NEMA standard hole pattern

Governing System

  • ADEM III

Literature

  • Parts book
  • Operation & Maintenance Manual

Lube System

  • Integral lube Oil cooler
  • Fumes disposal
  • Oil drain lines and valve
  • Oil filter, filler and dipstick
  • Lubricating oil
  • Gear type lube oil pump

Mounting System

  • Rubber anti-vibration mounts - shipped loose
  • Rails

Starting / Charging System

  • 45 Amp Charging alternator
  • Battery and battery rack w/cables
  • 24 Volt electric starting motor

General

  • Flywheel and flywheel housing-SAE No. 00
  • SAE standard rotation
  • Paint - Caterpillar yellow with high gloss black rails & radiator
  • Right hand servicing

Power Termination

  • Busbar
  • Busbar
Optional Equipment

Air Inlet System

Circuit breakers

Air Cleaner

  • Dual element with service indicator

Muffler

  • Industrial grade (15 dB)
  • Critical grade (25 dB)
  • Hospital grade (35 dB)

Control Panel

Starting

  • Standard batteries
  • Oversized batteries
  • Air starter(s)
  • Jacket water heater

Cooling System

Exhaust System

Fuel System

Generators and attachments

Instrumentation

Lube System

Mounting System

Power Connections

Special Tests / Reports

Output Voltage

  • 416V
  • 480V
  • 600V
  • 4160V
  • 12470V
  • 13200V
  • 13800V

Starting / Charging System

Alternator Temperature rise (over 40°C ambient)

  • 150°C
  • 125°C/130°C
  • 105°C
  • 80°C

General

Alternator attachments

  • Anti-condensation space heater
  • Stator and bearing temperature monitoring and protection

Power termination

  • Circuit breakers, IEC compliant
  • Bus bar
  • Circuit breaker
  • 1600A
  • 2000A
  • 2500A
  • 3000A
  • 3200A
  • 4000A
  • 5000A
  • IEC
  • UL
  • 3-pole
  • 4-pole
  • Manually operated
  • Electrically operated

Trip Unit

  • LSI
  • LSI-G
  • LSI-P
  • LSIG-P

Controller

  • Cat ECS 200
  • EMCP 4.4

Controller attachments

  • Local annunciator module
  • Remote annuciator module
  • Expansion I/O module
  • Remote monitoring software

Charging

  • Battery charger - 10A
  • Battery charger - 20A
  • Battery charger - 40A
  • Battery charger - 50A

Cooling

  • No Radiator
  • High Ambient Radiator

Crankcase Ventilation System

  • Filtered crankcase ventilation
  • Closed filtered crankcase ventilation

Vibration Isolators

  • Spring
  • Seismic rated

Telematics

  • Cellular

Extended service terms

  • 2 year (prime)
  • 3 year
  • 5 year
  • 10 year

Extended service coverage

  • Silver
  • Gold
  • Platinum
  • Platinum plus

Ancilliary Equipment

  • Automatic transfer switch (ATS)
  • Paralleling switchgear
  • Paralleling switchgear
  • Paralleling controls

Certifications

  • UL 2200
  • IBC seismic certification
  • OSHPD pre-approval