3516E Generator Set
THE RUNDOWN
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
Cat ECS Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Designed to operate in standard ambient temperatures up to 50°C (122°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
- EU Declaration of Conformity
- EU Declaration of Incorporation
- Eurasian Conformity (EAC)
One Safe Source
- Components used in the generator set are selected at the design stage to provide optimum package performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Cat® Diesel Engine
- Rugged, durable design with reliable performance proven in thousands of applications worldwide
- Certified alternative fuels including Hydrotreated Vegetable Oil (HVO), Renewable Diesel (RD) and Hydrotreated Renewable Diesel (HRD) which meet EN 15940 or ASTM D975 can be used or blended with EN 590 diesel
Cat Generator Set Package
- Accepts 100% block load in one step
- Meets NFPA 110 loading requirements
- Conforms to ISO 8528-5 G3 load acceptance requirements
- Reliability verified through torsional vibration, fuel consumption, oil consumption, transient performance, and endurance testing
Alternators
- Superior motor starting capability minimizes need for oversizing generator
- Designed to match performance and output characteristics of Cat diesel engines
Cooling System
- Cooling systems are available to operate in ambient temperatures up to 50°C (122°F)
- Tested to ensure proper generator set cooling
Cat® Energy Control System (ECS)
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirements
- Expansion modules and site specific programming for specific customer requirements
- Graphical touchscreen display
- Easily upgradeable
Warranty
- 24 months/1000-hour warranty for Standby and Mission Critical ratings
- 12 months/unlimited hour warranty for Prime and Continuous ratings
- 12 months/unlimited hour warranty for Prime-DCP ratings
- Extended service protection is available to provide extended coverage options
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Financing
- Caterpillar offers an array of financial products to help you succeed through financial service excellence
- Options include loans, finance lease, operating lease, working capital, and revolving line of credit
- Contact your local Cat dealer for availability in your region
Generator Set Specifications
| Standby Rating | 3500/3250/3000 kVA |
| Prime Power Rating | 3175/2950/2725 kVA |
| Emissions/Fuel Strategy | U.S. EPA Cert. Tier 2 / Low NOx |
| Voltage | 380 to 11000 volts |
| Frequency | 50 Hz |
| Speed | 1500 rpm |
| Duty Cycle | Standby, Mission Critical, Prime |
| Maximum Rating | 3500 kVA |
| Minimum Rating | 2725 kVA |
Engine Specifications
| Engine Model | 3516E, V-16, 4-Stroke Water-Cooled Diesel |
| Bore | 6.69in |
| Stroke | 8.46in |
| Displacement | 4765in³ |
| Compression Ratio | 14.0:1 |
| Aspiration | ATAAC |
| Fuel System | Electronic Unit Injection |
| Governor Type | Adem™ A5 |
Generator Set Dimensions
| Length - Minimum | 313.4in |
| Length - Maximum | 318.4in |
| Width - Minimum | 104in |
| Width - Maximum | 104in |
| Height - Minimum | 131.6in |
| Height - Maximum | 131.6in |
| Dry Weight - Genset (minimum) | 44930lb |
| Dry Weight - Genset (maximum) | 45651lb |
Standard Equipment
Air Inlet System
- Air cleaner; single element canister type
Air Cleaner
- Dual element
Starting
- Dual electric starters
Control System
- Generator set packages include:
- Emergency stop pushbutton
- 24 Volt DC operation
- IVR includes reactive droop capability
- Cat ECS 100
- Text alarm/event descriptions
- Generator mounted - rear facing
- Environmental sealed front face
- RFI suppression
- 3 Phase voltage sensing
- Caterpillar's voltage regulator
- Min / max exciter
- Limiter and exciter diode monitor
- Controls:
- Speed adjust
- Auto/start/stop control
- Engine cycle crank
- Engine cool
- Alarm acknowledge
- PLC functionality
- Customizable screens
- Lamp test
- Generator phase sequence
- 1 Programmable relay outputs (Form C)
- RPM
- High coolant temperature
- Accessory module data link
- Number of I/O varies on options selected
- Digital indication for:
- Reverse power (kW) (32)
- Reverse reactive power (kVAr) (32RV)
- Overcurrent (50/51)
- 6 Customer programmable digital inputs
- 3 Analog inputs
- Serial annunciator module data link
- Over/under frequency (81 o/u)
- Low coolant temperature
- +/- 2% accuracy
- Programmable protective relaying functions:
- Failure to start (overcrank)
- 4 Programmable relay outputs (Form A)
- Cat connect
- Over/under voltage (27/59)
- 1 Programmable digital outputs
- 0 True RMS AC metering
- 3 Phase
- Communications:
- Overspeed
- DC volts
- Operating hours
- Coolant temperature
- Oil pressure (psi, kPa or bar)
- Volts (L-L & L-N)
- Power factor (per phase & average)
- Frequency (Hz)
- Amps (per phase & average)
- kW (per phase, average & percent)
- kVA (per phase, average & percent)
- kVAr (per phase, average & percent)
- Low oil pressure
- kVAr-hr (total)
- kW-hr (total)
- Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level -
Cooling
- Standard Ambient Radiator
Crankcase Ventilation System
- Non filtered crankcase ventilation
Cooling System
- ATAAC - 3516E package radiators shipped installed
- Certified standard PGS provided
Exhaust System
- Dry exhaust manifold
- Flanged faced outlet(s)
Fuel System
- Fuel cooler; not included with packages without radiator
- Secondary fuel filters
- Flexible fuel lines - shipped loose
General
- SAE standard rotation
- Flywheel and flywheel housing - SAE No. 00
- Caterpillar yellow with high gloss black rails and radiator
Mounting System
- Rails
- Rails - Engine/generator/radiator mounting
- Anti-vibration mounts (shipped loose)
- Rubber anti-vibration mounts - shipped loose
Generator and Attachments
- Anti-condensation space heater
- Low voltage: Random wound - Internal excitation (IE) - Winding temperature detectors - NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby) - Busbar connections, top center mounted, top cable entry - NEMA standard hole pattern
- 3 Phase brushless, Salient pole
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
- Winding temperature detectors
- High voltage:
- Medium voltage:
- Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
- NEMA standard hole pattern
- 6 Lead
- Permanent magnet excitation (PMG)
- Form wound
- Busbar connections, right side extension box, bottom cable entry
Governing System
- ADEM A5
Literature
- Operation & Maintenance Manual
Controller
- Cat ECS 100
Lubrication System
- Gear type lube oil pump
- Lubricating oil
- Oil filter, filler and dipstick
- Integral lube oil cool
- Oil drain lines and valve
- Fumes disposal
Starting System
- 24 Volt electric starting motor
- 45 Amp Charging alternator
- Battery and battery rack w/cables
- Battery disconnect switch
Telematics
- Ethernet
Alternator
- Random Wound
- Permanent Magnet (PM) Excitation
Power Termination
- Busbar
Optional Equipment
Control System
- EMCP 4.4
Air Inlet System
- Single element filter
- Dual element air cleaner
Cooling System
- Standard ambient ATAAC radiators
- Water level switch gauges
- Optional installed ATAAC radiators
- Coolant
- Optional installed radiators
- Standard ambient radiators
Crankcase System
- Ventilation system
- Explosion relief valves
- No explosion relief valves
Air Cleaner
- Dual element with service indicator
Exhaust System
- Y Adapters
Fuel System
- Primary fuel filter
- Fuel priming pumps (Tier 4) - Manual or electric
General
- US aid emblem
- Special paint (Colors other than Caterpillar yellow or high performance paints)
Generators and Attachments
- Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
- Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
- Alternator air cleaner
- Differential current transformers (DCT) 8.7 kV and 15 kV classes
- Generator conversion
Starting
- Standard batteries
- Oversized batteries
- Battery charger - 10A
- Battery charger - 20A
- Battery charger - 40A
- Air starter(s)
- Jacket water heater
Instrumentation
Lubrication System
- Lube oil in standard sump
- Prelube pumps
- Oil level regulator
Power Connections
- Center post busbars
Cooling
- No Radiator
- High Ambient Radiator
Special Tests / Reports
- Generator set fuel consumption test
- Torsional vibration analysis reports
- PGS Test report @ 0.8 power factor
- IBC Certification
- Canadian Standards Association certification
- Generator test report
- Fuel consumption test
- OSHPD Certification
Starting and Charging
- Air pressure regulator
- Jacket water heaters
- Air starting motors
- Starter cover
- Engine barring device
- 10, 20, 35 and 50 Amp Battery chargers
- Electric starting motors
Crankcase Ventilation System
- Filtered crankcase ventilation
Muffler
- Industrial grade (15 dB)
- Critical grade (25 dB)
- Hospital grade (35 dB)
Mounting System
- Spring type vibration isolators
- IBC vibration isolators
- Spring vibration Isolators
- No Isolators
Controller
- Cat ECS 200
- EMCP 4.4
Controller attachments
- Local annunciator module
- Remote annuciator module
- Expansion I/O module
- Remote monitoring software
Telematics
- Cellular
Extended service terms
- 2 year (Prime)
- 3 year
- 5 year
- 10 year
Extended service coverage
- Platinum, Gold and Silver coverage
- Silver
- Gold
- Platinum
- Platinum plus
Alternator
- Form Wound
Alternator Temperature rise (over 40°C ambient)
- 125°C
- 130°C
- 150°C
Alternator Output Voltage
- 400V
- 415V
- 3300V
- 10000V
- 10500V
- 11000V
Alternator attachments
- Anti-condensation space heater
- Stator and bearing temperature monitoring and protection
Power termination
- Circuit breaker
Circuit breaker
- 1600A
- 2000A
- 2500A
- 3000A
- 3200A
- 4000A
- 5000A
- IEC
- UL
- 3-pole
- 4-pole
- Manually operated
- Electrically operated
Trip Unit
- LSI
- LSI-G
- LSI-P
Ancilliary Equipment
- Automatic transfer switch (ATS)
- Paralleling switchgear
- Paralleling controls
Certifications
- IBC seismic certification
- EU & GB Declaration of Conformity
- EU & GB Declaration of Incorporation
- Eurasian Conformity (EAC)