3516C (50 Hz)

3516C Generator Set

THE RUNDOWN

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
Cat ECS Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • IBC seismic certification
  • EU Declaration of Conformity
  • EU Declaration of Incorporation
  • Eurasian Conformity (EAC)
One Safe Source
  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Cat® Diesel Engine
  • Rugged, durable design with reliable performance proven in thousands of applications worldwide
  • Certified alternative fuels including Hydrotreated Vegetable Oil (HVO), Renewable Diesel (RD) and Hydrotreated Renewable Diesel (HRD) which meet EN 15940 or ASTM D975 can be used or blended with EN 590 diesel
Cat Generator Set Package
  • Accepts 100% block load in one step
  • Meets NFPA 110 loading requirements
  • Conforms to ISO 8528-5 G3 load acceptance requirements
  • Reliability verified through torsional vibration, fuel consumption, oil consumption, transient performance, and endurance testing
Alternators
  • Superior motor starting capability minimizes need for oversizing generator
  • Designed to match performance and output characteristics of Cat diesel engines
Cooling System
  • Cooling systems are available to operate in ambient temperatures up to 50°C (122°F)
  • Tested to ensure proper generator set cooling
Cat® Energy Control System (ECS)
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirements
  • Expansion modules and site specific programming for specific customer requirements
  • Graphical touchscreen display
  • Easily upgradeable
Warranty
  • 24 months/1000-hour warranty for Standby and Mission Critical ratings
  • 12 months/unlimited hour warranty for Prime and Continuous ratings
  • 12 months/unlimited hour warranty for Prime-DCP ratings
  • Extended service protection is available to provide extended coverage options
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Financing
  • Caterpillar offers an array of financial products to help you succeed through financial service excellence
  • Options include loans, finance lease, operating lease, working capital, and revolving line of credit
  • Contact your local Cat dealer for availability in your region
Generator Set Specifications
Standby Rating2750 kVA
Prime Power Rating2500 kVA
Emissions/Fuel StrategyLow Fuel, Low Emissions
Voltage380 to 11000 volts
Frequency50 Hz
Speed1500 rpm
Duty CycleStandby, Mission Critical, Prime, Continuous
Maximum Rating2750 kVA
Minimum Rating2500 kVA
Engine Specifications
Engine Model3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel
Bore6.69in
Stroke8.46in
Displacement4764.73in
Compression Ratio14.7:1
AspirationTA
Fuel SystemElectronic unit injection
Governor TypeAdem™3
Generator Set Dimensions
Length - Maximum276.3in
Width - Maximum92.1in
Height - Maximum118.2in
Dry Weight - Genset (maximum)39090lb
Standard Equipment

Air Inlet

  • Air cleaner

Exhaust

  • Exhaust flange outlet

Fuel

  • Fuel priming pump
  • Secondary fuel filters
  • Primary fuel filter with integral water separator

Air Cleaner

  • Single element with service indicator

Generator

  • Matched to the performance and output characteristics of Cat engines
  • IP23 Protection

Control Panel

  • Cat ECS 100

General

  • Paint - Caterpillar yellow except rails and radiators gloss black

Starting

  • Dual electric starters

Cooling

  • Package mounted radiator
  • Standard Ambient Radiator

Mounting System

  • Rails

Controller

  • Cat ECS 100

Telematics

  • Ethernet

Alternator

  • Form Wound
  • Permanent Magnet (PM) Excitation

Power Termination

  • Busbar
  • Busbar
Optional Equipment

Exhaust

  • Exhaust mufflers

Generator

  • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
  • Anti-condensation heater
  • Oversize and premium generators

Air Cleaner

  • Dual element with service indicator

Control Panels

  • EMCP 4.4
  • Digital I/O module
  • Load share module
  • Generator temperature monitoring & protection
  • Remote monitoring software

Mounting

  • Spring type vibration isolators
  • Rubber anti-vibration mounts
  • IBC isolators

Starting/Charging

  • Jacket water heater
  • Charging alternator
  • Oversize batteries
  • Battery chargers
  • Heavy duty starting system
  • Air starting motor with control and silencer

General

  • UL 2200 package
  • EU Certificate of Conformance (CE)
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • EEC Declaration of Conformity
  • Integral & sub-base UL listed dual wall fuel tanks
  • The following options are based on regional and product configuration:
  • Automatic transfer switches (ATS)
  • Enclosures: Sound attenuated, weather protective
  • CSA Certification
  • Integral & sub-base fuel tanks

Starting

  • Standard batteries
  • Oversized batteries
  • Battery charger - 10A
  • Battery charger - 20A
  • Battery charger - 40A
  • Air starter(s)
  • Jacket water heater

Cooling

  • No Radiator
  • High Ambient Radiator

Muffler

  • Industrial grade (15 dB)

Mounting System

  • Rubber
  • Spring vibration Isolators
  • Seismic rated vibration isolators
  • No Isolators

Controller

  • Cat ECS 200
  • EMCP 4.4

Controller attachments

  • Local annunciator module
  • Remote annuciator module
  • Expansion I/O module
  • Remote monitoring software

Telematics

  • Cellular

Extended service terms

  • 2 year (Prime)
  • 3 year
  • 5 year
  • 10 year

Extended service coverage

  • Silver
  • Gold
  • Platinum
  • Platinum plus

Alternator Temperature rise (over 40°C ambient)

  • 80°C
  • 125°C
  • 130°C
  • 150°C

Alternator Output Voltage

  • 400V
  • 3300V
  • 10000V
  • 10500V
  • 11000V

Alternator attachments

  • Anti-condensation space heater
  • Stator and bearing temperature monitoring and protection

Power termination

  • Circuit breakers, IEC compliant
  • Circuit breakers, UL listed
  • Circuit breaker

Circuit breaker

  • 1600A
  • 2000A
  • 2500A
  • 3000A
  • 3200A
  • 4000A
  • 5000A
  • IEC
  • UL
  • 3-pole
  • 4-pole
  • Manually operated
  • Electrically operated

Trip Unit

  • LSI
  • LSI-G
  • LSI-P
  • LSIG-P

Ancilliary Equipment

  • Automatic transfer switch (ATS)
  • Paralleling switchgear
  • Paralleling controls

Certifications

  • IBC seismic certification
  • EU & GB Declaration of Conformity
  • EU & GB Declaration of Incorporation
  • Eurasian Conformity (EAC)

Cat Switchgear

›
Cat Switchgear
ConfigurationIP4X
Operating Temperature35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)
Standard Widths600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.