Cat® 3516C (50 Hz) with Upgradeable Package

3516C (50 Hz) with Upgradeable Package

THE RUNDOWN

Cat® Diesel Engine
  • Rugged, durable design with reliable performance proven in thousands of applications worldwide
  • Certified alternative fuels including Hydrotreated Vegetable Oil (HVO), Renewable Diesel (RD) and Hydrotreated Renewable Diesel (HRD) which meet EN 15940 or ASTM D975 can be used or blended with EN 590 diesel
Cat Generator Set Package
  • Accepts 100% block load in one step
  • Meets NFPA 110 loading requirements
  • Conforms to ISO 8528-5 G3 load acceptance requirements
  • Reliability verified through torsional vibration, fuel consumption, oil consumption, transient performance, and endurance testing
Alternators
  • Superior motor starting capability minimizes need for oversizing generator
  • Designed to match performance and output characteristics of Cat diesel engines
EMCP 4 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Cooling systems are available to operate in ambient temperatures up to 50°C (122°F)
  • Tested to ensure proper generator set cooling
Warranty
  • 24 months/1000-hour warranty for Standby and Mission Critical ratings
  • 12 months/unlimited hour warranty for Prime and Continuous ratings
  • 12 months/unlimited hour warranty for Prime-DCP ratings
  • Extended service protection is available to provide extended coverage options
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Financing
  • Caterpillar offers an array of financial products to help you succeed through financial service excellence
  • Options include loans, finance lease, operating lease, working capital, and revolving line of credit
  • Contact your local Cat dealer for availability in your region
Generator Set Specifications
Standby Rating2750 kVA
Prime Power Rating2500 kVA
Emissions/Fuel StrategyLow Fuel Consumption
Voltage380 to 11000 volts
Frequency50 Hz
Speed1500 rpm
Duty CycleStandby, Mission Critical, Prime, Continuous
Maximum Rating2750 kVA
Minimum Rating2275 kVA
Engine Specifications
Engine Model3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel
Bore6.69in
Stroke8.46in
Displacement4765in
Compression Ratio14:01
AspirationTA
Fuel SystemElectronic unit injection
Governor TypeAdem™3
Generator Set Dimensions
Length - Maximum228.3in
Width - Maximum75.9in
Height - Maximum80.7in
Dry Weight - Genset (maximum)32404lb
Standard Equipment

Air Inlet System

  • Air cleaner

Control Panel

  • RPM
  • Engine cycle crank
  • Failure to start (overcrank)
  • Warning/shutdown with common LED indication of shutdowns for:
  • Speed adjust
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Overcurrent (50/51)
  • Controls:
  • Generator phase sequence
  • Low oil pressure
  • 2 Programmable digital outputs
  • Reverse power (kW) (32)
  • Operating hours
  • Frequency (Hz)
  • kVAr-hr (total)
  • kVA (per phase, average & percent)
  • Lamp test
  • Over/under frequency (81 o/u)
  • 6 programmable digital inputs
  • 2 Programmable relay outputs (Form C)
  • 24 Volt DC operation
  • Customer data link (Modbus RTU)
  • EMCP 4 Genset controller
  • Volts (L-L & L-N)
  • High coolant temperature
  • Alarm acknowledge
  • Oil pressure (psi, kPa or bar)
  • 4 Programmable relay outputs (Form A)
  • Overspeed
  • EMCP4.2B controller includes:
  • Engine cool-down timer
  • Panel lights
  • kW (per phase, average & percent)
  • Low coolant temperature
  • Over/under voltage (27/59)
  • Serial annunciator module data link
  • Digital indication for:
  • Text alarm/event descriptions
  • EMCP 4.2B
  • Coolant temperature
  • Emergency stop pushbutton
  • Programmable protective relaying functions:
  • kW-hr (total)
  • Reverse reactive power (kVAr) (32RV)
  • Amps (per phase & average)
  • Environmental sealed front face
  • Power factor (per phase & average)

Exhaust

  • Exhaust flange outlet

Fuel

  • Primary fuel filter with integral water separator

Air Cleaner

  • Single element with service indicator
  • Single element with service indicator

Generator

  • IP23 Protection
  • Matched to the performance and output characteristics of Cat engines

Starting

  • Heavy duty electric starter(s)
  • Heavy duty electric starter(s)

Starting/Charging

  • Heavy duty starting system
  • Charging alternator

Cooling

  • ATAAC
  • Standard Ambient Radiator
  • Package mounted radiator

Crankcase Ventilation System

  • Non filtered crankcase ventilation
  • Non filtered crankcase ventilation

Cooling System

  • Fan and belt guards
  • Coolant drain line with valve
  • JWAC
  • Caterpillar extended life coolant
  • Radiator fan and fan drive

Exhaust System

  • Flanged faced outlet(s)
  • Dry exhaust manifold

Fuel System

  • Flexible fuel lines - shipped loose
  • Fuel priming pump
  • Fuel cooler; not included with packages without radiator
  • Secondary fuel filters

Generators and Attachments

  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby).
  • Busbar connections, top center mounted, top cable entry
  • Random wound
  • 6 Lead
  • IEC standard hole pattern

Governing System

  • ADEM III

Literature

  • Parts book
  • Operation & Maintenance Manual

Lube System

  • Integral lube Oil cooler
  • Fumes disposal
  • Lubricating oil
  • Oil filter, filler and dipstick
  • Oil drain lines and valve

Mounting System

  • Rails
  • Rails
  • Rubber anti-vibration mounts - shipped loose

Starting / Charging System

  • 24 Volt electric starting motor
  • Battery and battery rack w/cables
  • Battery disconnect switch

General

  • Right hand servicing
  • Flywheel and flywheel housing-SAE No. 00
  • SAE standard rotation

Controller

  • EMCP 4.2B
  • EMCP 4.2B

Telematics

  • Ethernet
  • Ethernet

Alternator

  • Random wound
  • Form wound
  • Permanent Magnet Excitation
  • Internal excitation (IE)

Power Termination

  • Busbar
  • Busbar
  • Busbar
Optional Equipment

Air Inlet System

Circuit breakers

  • Cable entry options
  • Control packaging for enclosures
  • Load take off; IEC standard hole
  • Busbar power connections
  • Center posts busbars

Power Termination

  • Circuit breakers, IEC compliant

Air Cleaner

  • Dual element with service indicator
  • Dual element with service indicator

Control Panels

  • Busbar connections

Cooling System

European Certifications

Exhaust System

Fuel System

Starting

  • Standard batteries
  • Standard batteries
  • Oversized batteries
  • Oversized batteries
  • Battery charger - 10A
  • Battery charger - 10A
  • Battery charger - 20A
  • Battery charger - 20A
  • Battery charger - 40A
  • Battery charger - 40A
  • Battery charger - 50A
  • Battery charger - 50A
  • Air starter(s)
  • Air starter(s)
  • Jacket water heater
  • Jacket water heater

Generators and attachments

Instrumentation

Lube System

Protection System

Special Tests / Reports

Cooling

  • No Radiator
  • No Radiator
  • High Ambient Radiator
  • High Ambient Radiator

Starting / Charging System

Crankcase Ventilation System

  • Filtered crankcase ventilation
  • Filtered crankcase ventilation
  • Closed filtered crankcase ventilation
  • Closed filtered crankcase ventilation

General

Muffler

  • Industrial grade (15 dB)
  • Industrial grade (15 dB)
  • Critical grade (25 dB)
  • Critical grade (25 dB)
  • Hospital grade (35 dB)
  • Hospital grade (35 dB)

Mounting System

  • Spring vibration Isolators
  • Spring vibration Isolators
  • Seismic rated vibration isolators
  • Seismic rated vibration isolators

Controller

  • EMCP 4.3
  • EMCP 4.4
  • EMCP 4.3
  • EMCP 4.4

Controller attachments

  • Local annunciator module
  • Remote annuciator module
  • Expansion I/O module
  • Local annunciator module
  • Remote monitoring software
  • Remote annuciator module
  • Expansion I/O module
  • Remote monitoring software

Telematics

  • Cellular
  • Cellular

Extended service terms

  • 2 year (prime)
  • 2 year (prime)
  • 3 year
  • 5 year
  • 5 year
  • 10 year
  • 10 year

Extended service coverage

  • Silver
  • Silver
  • Gold
  • Gold
  • Platinum
  • Platinum
  • Platinum plus
  • Platinum plus

Alternator

  • Form wound
  • Permanent Magnet (PM) Excitation

Alternator Temperature rise (over 40°C ambient)

  • 80°C
  • 105°C
  • 125°C/130°C
  • 150°C
  • 80°C
  • 105°C
  • 125°C/130°C
  • 150°C

Alternator Output Voltage

  • 416V
  • 480V
  • 600V
  • 4160V
  • 12470V
  • 13200V
  • 13800V
  • 380V
  • 400V
  • 415V
  • 6300V
  • 6600V
  • 6900V
  • 10000V
  • 10500V
  • 11000V

Alternator attachments

  • Anti-condensation space heater
  • Stator and bearing temperature monitoring and protection
  • Anti-condensation space heater
  • Stator and bearing temperature monitoring and protection

Circuit breaker

  • 5000A
  • 5000A
  • IEC
  • IEC
  • UL
  • 3-pole
  • 3-pole
  • 4-pole
  • Manually operated
  • Manually operated
  • Electrically operated
  • Electrically operated

Trip Unit

  • LSI
  • LSI
  • LSI-G
  • LSI-G
  • LSIG-P
  • LSIG-P

Ancilliary Equipment

  • Automatic transfer switch (ATS)
  • Automatic transfer switch (ATS)
  • Paralleling switchgear
  • Paralleling switchgear
  • Paralleling controls
  • Paralleling controls

Certifications

  • IBC seismic certification
  • EU & GB Declaration of Conformity
  • EU & GB Declaration of Incorporation
  • Eurasian Conformity (EAC)
  • Telecommunication Lab of China

Cat Switchgear

›
Cat Switchgear
ConfigurationIP4X
Operating Temperature35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)
Standard Widths600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.