Cat® 3516B (50 Hz) with Upgradeable Package

3516B Generator Set

THE RUNDOWN

Cat® Diesel Engine
  • Rugged, durable design with reliable performance proven in thousands of applications worldwide
  • Certified alternative fuels including Hydrotreated Vegetable Oil (HVO), Renewable Diesel (RD) and Hydrotreated Renewable Diesel (HRD) which meet EN 15940 or ASTM D975 can be used or blended with EN 590 diesel
Cat Generator Set Package
  • Accepts 100% block load in one step
  • Meets NFPA 110 loading requirements
  • Conforms to ISO 8528-5 G3 load acceptance requirements
  • Reliability verified through torsional vibration, fuel consumption, oil consumption, transient performance, and endurance testing
Alternators
  • Superior motor starting capability minimizes need for oversizing generator
  • Designed to match performance and output characteristics of Cat diesel engines
Cooling System
  • Cooling systems are available to operate in ambient temperatures up to 50°C (122°F)
  • Tested to ensure proper generator set cooling
EMCP 4 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Warranty
  • 24 months/1000-hour warranty for Standby and Mission Critical ratings
  • 12 months/unlimited hour warranty for Prime and Continuous ratings
  • 12 months/unlimited hour warranty for Prime-DCP ratings
  • Extended service protection is available to provide extended coverage options
World Wide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Financing
  • Caterpillar offers an array of financial products to help you succeed through financial service excellence
  • Options include loans, finance lease, operating lease, working capital, and revolving line of credit
  • Contact your local Cat dealer for availability in your region
Generator Set Specifications
Standby Rating2250 kVA
Prime Power Rating2000 kVA
Emissions/Fuel StrategyLow fuel, Low Emissions
Voltage380 to 11000 Volts
Frequency50 Hz
Speed1500 rpm
Duty CycleStandby, Mission Critical, Prime, Continuous
Maximum Rating2250 kVA
Minimum Rating1750 kVA
Engine Specifications
Engine Model3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Bore6.69in
Stroke7.48in
Displacement4210.64in
Compression Ratio14.0:1 Std
AspirationTA
Fuel SystemElectronic unit injection
Governor TypeAdem™3
Generator Set Dimensions
Length - Maximum234.5in
Width - Maximum90in
Height - Maximum98.2in
Dry Weight - Genset (maximum)34460lb
Standard Equipment

Air Inlet System

  • Air cleaner; single element canister type

Air Cleaner

  • Single element with service indicator

Starting

  • Standard electric starter(s)

Cooling

  • ATAAC
  • Standard Ambient Radiator

Control Panels

  • Auto/start/stop control
  • Engine cool-down timer
  • Environmental sealed front face
  • Emergency stop pushbutton
  • Text alarm/event descriptions
  • 24 Volt DC operation
  • Controls:
  • Generator mounted - Rear facing
  • IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min / max exciter.
  • Generator set packages include Caterpillar's voltage regulator
  • EMCP 4.2B
  • Speed adjust
  • Alarm acknowledge
  • Engine cycle crank
  • Load histogram feature
  • Lamp test
  • Digital indication for:
  • RPM
  • PLC functionality
  • Operating hours
  • Oil pressure (psi, kPa or bar)
  • Coolant temperature
  • DC volts
  • Volts (L-L & L-N)
  • kW (per phase, average & percent)
  • Amps (per phase & average)
  • Frequency (Hz)
  • kVA (per phase, average & percent)
  • kVAr (per phase, average & percent)
  • Low oil pressure - High coolant temperature
  • kVAr-hr (total)
  • High coolant temperature
  • Warning/shutdown with common LED indication of shutdowns for:
  • kW-hr (total)
  • Overspeed
  • Low coolant temperature
  • Failure to start (overcrank)
  • Over/under voltage (27 / 59)
  • Generator phase sequence
  • Low coolant level
  • Programmable protective relaying functions:
  • 6 Customer programmable digital inputs
  • Over/under frequency (81 o/u)
  • Reverse reactive power (kVAr) (32RV)
  • Serial annunciator module data link
  • Reverse power (kW) (32)
  • Number of I/O varies on options selected
  • Cat connect
  • 4 Programmable relay outputs (Form A)
  • Communications:
  • Customer data link (Modbus RTU)
  • 1 Programmable digital outputs
  • Accessory module data link
  • 3 Analog inputs

Crankcase Ventilation System

  • Non filtered crankcase ventilation

Cooling System

  • Certified standard PGS provided

Exhaust System

  • Dry exhaust manifold
  • Flanged faced outlet(s)

Fuel System

  • Fuel cooler; not included with packages without radiator
  • Secondary fuel filters
  • Fuel priming pump
  • Flexible fuel lines - shipped loose

General

  • Right hand servicing
  • SAE standard rotation
  • Flywheel and flywheel housing - SAE No. 00
  • Caterpillar yellow with high gloss black rails and radiator

Mounting System

  • Rails
  • Rails - Engine/generator/radiator mounting
  • Rubber anti-vibration mounts - shipped loose
  • Anti-vibration mounts (shipped loose)

Generator and Attachments

  • Busbar connections, right side extension box, bottom cable entry
  • High voltage:
  • Form wound
  • Internal excitation (IE)
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • 3 Phase brushless, Salient pole
  • Medium voltage:
  • NEMA standard hole pattern
  • Permanent magnet excitation (PMG)
  • Permanent magnet excitation (PMG)
  • Winding temperature detectors
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
  • Winding temperature detectors
  • Low voltage:
  • Form wound
  • 6 Leads  
  • Random wound
  • Anti-condensation space heater
  • Winding temperature detectors
  • Busbar connections, top center mounted, top cable entry

Governing System

  • ADEM A3

Literature

  • Parts book

Lubrication System

  • Integral lube oil cool
  • Oil filter, filler and dipstick
  • Gear type lube oil pump
  • Oil drain lines and valve
  • Fumes disposal

Controller

  • EMCP 4.2B

Starting System

  • 24 Volt electric starting motor
  • 45 Amp Charging alternator
  • Battery disconnect switch
  • Battery and battery rack w/cables

Telematics

  • Ethernet

Alternator

  • Random wound
  • Internal excitation (IE)

Power Termination

  • Busbar
Optional Equipment

Control System

  • EMCP 4.3, EMCP 4.4
  • Controller: [ ] EMCP 4.2 [ ] EMCP 4.3 [ ] EMCP 4.4
  • Local annunciator module: [ ] NFPA 110 [ ] Custom

Air Inlet System

  • Dual element air cleaner
  • Single element filter

Engine Options

  • Air cleaner: [ ] Single element air cleaners [ ] Dual element air cleaners [ ] Heavy duty air cleaners
  • Battery charger: [ ] 10A [ ] 20A [ ] 35A
  • Starting aids: [ ] 220V 50 Hz Jacket water heater
  • Muffler: [ ] Industrial Grade
  • Starting motors: [ ] Standard [ ] Heavy duty
  • Batteries: [ ] Standard (1400 CCA) [ ] Heavy Duty (2800 CCA)

Cooling System

  • Standard ambient radiators
  • Coolant
  • Optional installed radiators
  • Optional installed ATAAC radiators
  • Water level switch gauges
  • Standard ambient ATAAC radiators

Crankcase System

  • Ventilation system
  • No explosion relief valves
  • Explosion relief valves

Air Cleaner

  • Dual element with service indicator
  • Heavy duty

Exhaust System

  • Y Adapters
  • Flanges
  • Tier 4 clean emission MOD Kits
  • Clean emission parts
  • Flange and exhaust expanders
  • Flexible fittings
  • Exhaust offset
  • Mufflers
  • Tier 4 dosing cabinet
  • Tier 4 clean emissions module
  • Elbows

Alternators

  • Temperature rise (over 40°C ambient): [ ] 150°C [ ] 125°C [ ] 105°C [ ] 80°C

Power Termination

  • Power termination: [ ] Busbar [ ] Circuit breaker
  • Circuit breaker trip unit: [ ] LSI [ ] LSIG [ ] LSIG-P
  • Circuit breaker rating: [ ] 2000A [ ] 2500A [ ] 3200A [ ] 4000A

Fuel System

  • Fuel priming pumps (Tier 4) - Manual or electric
  • Primary fuel filter

Extended Service Contract (ESC)

  • Extended Service Contract (ESC): [ ] 2 Year [ ] 3 Year [ ] 5 Year

General

  • Special paint (Colors other than Caterpillar yellow or high performance paints)
  • US aid emblem

Starting

  • Standard batteries
  • Oversized batteries
  • Battery charger - 10A
  • Battery charger - 20A
  • Battery charger - 35A
  • Air starter(s)
  • Jacket water heater

Generators and Attachments

  • Generator conversion
  • Space heater
  • Alternator air cleaner
  • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
  • Differential current transformers (DCT)
  • Differential current transformers (DCT) 8.7 kV and 15 kV classes
  • Thermostat for space heater
  • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames

Instrumentation

  • Pyrometer and thermocouples

Lubrication System

  • Oil level regulator
  • Prelube pumps
  • Lube oil in standard sump

Power Connections

  • Neutral ground connections
  • Center post busbars
  • Right side power connections
  • Left side power connections
  • 2700 Frame, four lead, four terminal
  • Ground cables between generator and terminal box
  • Low voltage Circuit breakers
  • Rear power connections

Special Tests / Reports

  • Torsional vibration analysis reports
  • Generator set fuel consumption test
  • PGS Test report @ 1.0 power factor
  • Fuel consumption test
  • Standard engine test charge
  • IBC Certification
  • OSHPD Certification
  • Canadian Standards Association certification
  • PGS Test report @ 0.8 power factor
  • Generator test report

Cooling

  • No Radiator
  • High Ambient Radiator

Crankcase Ventilation System

  • Filtered crankcase ventilation
  • Closed filtered crankcase ventilation

Starting and Charging

  • Air pressure regulator
  • Electric starting motors
  • Starter cover
  • Jacket water heaters
  • Engine barring device
  • 24 Volt battery set - Dry
  • 10, 20, 35 and 50 Amp Battery chargers
  • Air starting motors

Muffler

  • Industrial grade (15 dB)
  • Critical grade (25 dB)
  • Hospital grade (35 dB)

Mounting System

  • Puck style low efficiency isolators
  • IBC vibration isolators
  • Spring type vibration isolators
  • Spring vibration Isolators
  • Seismic rated vibration isolators

Controller

  • EMCP 4.3
  • EMCP 4.4

Controller attachments

  • Local annunciator module
  • Remote annuciator module
  • Expansion I/O module
  • Remote monitoring software

Telematics

  • Cellular

Extended service terms

  • 2 year (prime)
  • 3 year
  • 5 year
  • 10 year

Extended service coverage

  • Platinum, Gold and Silver coverage
  • Silver
  • Gold
  • Platinum
  • Platinum plus

Alternator

  • Form wound
  • Permanent Magnet (PM) Excitation

Alternator Temperature rise (over 40°C ambient)

  • 80°C
  • 105°C
  • 125°C/130°C
  • 150°C

Alternator Output Voltage

  • 380V
  • 400V
  • 415V
  • 6300V
  • 6600V
  • 6900V
  • 10000V
  • 10500V
  • 11000V

Alternator attachments

  • Anti-condensation space heater
  • Stator and bearing temperature monitoring and protection

Circuit breaker

  • 2000A
  • 2500A
  • 3200A
  • 4000A
  • IEC
  • 3-pole
  • Electrically operated

Trip Unit

  • LSI
  • LSI-G
  • LSIG-P

Ancilliary Equipment

  • Automatic transfer switch (ATS)
  • Paralleling switchgear
  • Paralleling controls

Certifications

  • EU & GB Declaration of Conformity
  • EU & GB Declaration of Incorporation
  • Eurasian Conformity (EAC)
  • Telecommunication Lab of China

Cat Switchgear

›
Cat Switchgear
ConfigurationIP4X
Operating Temperature35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)
Standard Widths600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.