3516B (60 Hz)

3516B Generator Set

THE RUNDOWN

Cat® Diesel Engine
  • Rugged, durable design with reliable performance proven in thousands of applications worldwide
  • Certified alternative fuels including Hydrotreated Vegetable Oil (HVO), Renewable Diesel (RD) and Hydrotreated Renewable Diesel (HRD) which meet EN 15940 or ASTM D975 can be used or blended with EN 590 diesel
Cat Generator Set Package
  • Accepts 100% block load in one step
  • Meets NFPA 110 loading requirements
  • Conforms to ISO 8528-5 G3 load acceptance requirements
  • Reliability verified through torsional vibration, fuel consumption, oil consumption, transient performance, and endurance testing
Alternators
  • Superior motor starting capability minimizes need for oversizing generator
  • Designed to match performance and output characteristics of Cat diesel engines
Cooling System
  • Cooling systems are available to operate in ambient temperatures up to 50°C (122°F)
  • Tested to ensure proper generator set cooling
Cat ECS Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirements
  • Expansion modules and site specific programming for specific customer requirements
  • Graphical touchscreen display
  • Easily upgradeable
Warranty
  • 24 months/1000-hour warranty for Standby and Mission Critical ratings
  • 12 months/unlimited hour warranty for Prime and Continuous ratings
  • 12 months/unlimited hour warranty for Prime-DCP ratings
  • Extended service protection is available to provide extended coverage options
World Wide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Financing
  • Caterpillar offers an array of financial products to help you succeed through financial service excellence
  • Options include loans, finance lease, operating lease, working capital, and revolving line of credit
  • Contact your local Cat dealer for availability in your region
Generator Set Specifications
Standby Rating2250 ekW
Prime Power Rating1825 ekW
Emissions/Fuel StrategyLow Fuel, Low Emissions
Voltage380 to 13800 Volts
Frequency60 Hz
Speed1800 rpm
Duty CycleStandby, Mission Critical, Prime, Continuous
Maximum Rating2250 ekW
Minimum Rating1640 ekW
Engine Specifications
Engine Model3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Bore6.69in
Stroke7.48in
Displacement4210.64in
Compression Ratio14.0:1 Std 15.5:1 HD
AspirationTA
Fuel SystemElectronic unit injection
Governor TypeAdem™3
Generator Set Dimensions
Length - Minimum241.8in
Length - Maximum269.9in
Width - Minimum90in
Width - Maximum101.9in
Height - Minimum98.2in
Height - Maximum120.1in
Dry Weight - Genset (minimum)31270lb
Dry Weight - Genset (maximum)34420lb
Standard Equipment

Air Inlet System

  • Air cleaner; single element canister type

Cooling

  • Package mounted radiator

Exhaust

  • Exhaust flange outlet

Fuel

  • Primary fuel filter with integral water separator
  • Secondary fuel filters
  • Fuel priming pump

Air Cleaner

  • Single element with service indicator

Generator

  • IP23 Protection
  • Matched to the performance and output characteristics of Cat engines

Control Panel

  • Cat ECS Genset controller

Starting

  • Heavy duty electric starter(s)

General

  • Paint - Caterpillar yellow except rails and radiators gloss black

Crankcase Ventilation System

  • Non filtered crankcase ventilation

Mounting System

  • Rails

Controller

  • Cat ECS 100

Control Panels

  • Speed adjust
  • Text alarm/event descriptions
  • Generator set packages include Caterpillar's voltage regulator
  • Auto/start/stop control
  • 24 Volt DC operation
  • Cat ECS 100
  • Generator mounted - Rear facing
  • Controls:
  • Environmental sealed front face
  • Engine cool-down timer
  • Emergency stop pushbutton
  • Engine cycle crank
  • Lamp test
  • Alarm acknowledge
  • Customizable screens
  • PLC functionality
  • Load histogram feature
  • Operating hours
  • Digital indication for:
  • DC volts
  • RPM
  • Coolant temperature
  • Amps (per phase & average)
  • Oil pressure (psi, kPa or bar)
  • Volts (L-L & L-N)
  • Frequency (Hz)
  • Power factor (per phase & average)
  • kW (per phase, average & percent)
  • High coolant temperature
  • Low oil pressure
  • Warning/shutdown with common LED indication of shutdowns for01/10/2018:
  • kVAr (per phase, average & percent)
  • kVA (per phase, average & percent)
  • kVAr (per phase, average & percent)
  • Emergency stop
  • Overspeed
  • Failure to start (overcrank)
  • Programmable protective relaying functions:
  • Low coolant temperature
  • Generator phase sequence
  • Low coolant level
  • Right hand servicing
  • Overcurrent (50/51)
  • 6 Lead
  • Flanged faced outlet(s)
  • Low voltage:
  • Number of I/O varies on options selected
  • Battery and battery rack w/cables
  • Over/under frequency (81 o/u)
  • Fuel cooler; not included with packages without radiator
  • Busbar connections, right side extension box, bottom cable entry
  • Rubber anti-vibration mounts - shipped loose
  • NEMA standard hole pattern
  • 1 Programmable digital outputs
  • Gear type lube oil pump
  • Battery disconnect switch
  • Caterpillar yellow with high gloss black rails and radiator
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • Medium voltage: Form wound - Permanent magnet excitation (PMG) - Winding temperature detectors - NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby) - Busbar connections, right side extension box, bottom cable entry - NEMA standard hole pattern
  • Permanent magnet excitation (PMG)
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • NEMA standard hole pattern
  • Reverse reactive power (kVAr) (32RV)
  • Over/under voltage (27/59)
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • Permanent magnet excitation (PMG)
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
  • Permanent magnet excitation (PMG)
  • SAE standard rotation
  • Internal excitation (IE)
  • Flexible fuel lines - shipped loose
  • IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min / max exciter
  • Busbar connections, right side extension box, bottom cable entry
  • Medium voltage:
  • Communications:
  • NEMA standard hole pattern
  • Lubricating oil
  • Oil drain lines and valve
  • 3 Phase brushless, Salient pole
  • 24 Volt electric starting motor
  • 6 Customer programmable digital inputs
  • Dry exhaust manifold
  • Accessory module data link
  • ADEM A3
  • Form wound
  • ATAAC - 3516E package radiators shipped installed
  • Busbar connections, top center mounted, top cable entry
  • High voltage:
  • Anti-condensation space heater
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • Controls: Speed adjust - Auto/start/stop control - Engine cool-down timer - Engine cycle crank - Alarm acknowledge - Lamp test - Load histogram feature - PLC functionality - Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
  • NEMA standard hole pattern
  • 45 Amp Charging alternator
  • 3 Analog inputs
  • Random wound
  • Anti-vibration mounts (shipped loose)
  • Cat connect
  • Oil filter, filler and dipstick
  • Rails - Engine/generator/radiator mounting
  • Customer data link (Modbus RTU)
  • Flywheel and flywheel housing - SAE No. 00
  • English
  • Busbar connections, right side extension box, bottom cable entry
  • Serial annunciator module data link
  • Integral lube oil cool
  • Certified standard PGS provided
  • Winding temperature detectors
  • 1 Programmable relay outputs (Form C)
  • Reverse power (kW) (32)
  • Form wound - Permanent magnet excitation (PMG)

Telematics

  • Ethernet

Alternator

  • Random wound
  • Internal Excitation (IE)

Power Termination

  • Busbar
  • Busbar
Optional Equipment

Control System

  • EMCP 4.4

Air Inlet System

  • Single element filter
  • Dual element air cleaner

Exhaust

  • Exhaust mufflers

Generator

  • Permanent magnet excitation (PMG)
  • Internal excitation (IE)
  • Anti-condensation heater
  • Oversize and premium generators

Cooling System

  • Water level switch gauges
  • Standard ambient radiators
  • Coolant
  • Standard ambient ATAAC radiators
  • Optional installed ATAAC radiators
  • Air inlet protection including air shut off magnetic switch
  • Optional installed radiator

Control Panels

  • Generator temperature monitoring & protection
  • Remote monitoring software
  • Load share module
  • Digital I/O module

Air Cleaner

  • Dual element with service indicator

Exhaust System

  • Exhaust Offset
  • Flanges
  • Elbows
  • Y Adapters
  • Flange and exhaust expanders
  • Clean emission parets
  • Mufflers

Fuel System

  • Primary fuel filter

General

  • Special paint
  • US aid emblem
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • EEC Declaration of Conformity
  • Integral & sub-base fuel tanks
  • Enclosures: Sound attenuated, weather protective
  • Integral & sub-base UL listed dual wall fuel tanks
  • EU Certificate of Conformance (CE)
  • The following options are based on regional and product configuration:
  • Automatic transfer switches (ATS)
  • UL 2200 package

Mounting

  • Rubber anti-vibration mounts
  • Spring type vibration isolators
  • IBC isolators

Generators and Attachments

  • 380, 440, 480, 600 Volts, 3 phase, 1800 rpm, RW, PM, No. of leads: 6, Picth: 0.6667 - 1600 Frame
  • 380, 440, 480, 600 Volts, 3 phase, 1800 rpm, RW, IE, No. of leads: 6, Picth: 0.6667 - 1600 Frame
  • 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 phase, 1800 rpm, RW, PM, No. of leads: 6, Picth: 0.6667 - 1600 and 1800 Frames
  • Alternator air cleaner
  • Space heater

Intrumentation

Lube System

  • Prelube pump groups
  • Lube oil

Starting/Charging

  • Battery chargers
  • Air starting motor with control and silencer
  • Heavy duty starting system
  • Oversize batteries
  • Charging alternator

Crankcase Systems

  • Crankcase ventilation system

Starting

  • Standard batteries
  • Oversized batteries
  • Battery charger - 10A
  • Battery charger - 20A
  • Battery charger - 40A
  • Air starter(s)
  • Jacket water heater

Power Connections

  • Neutral ground connections
  • Center post busbarss
  • Grounding groups

Special Tests / Reports

  • Standard engine test charge
  • Special package tests: PGS Test report @ 1.0 and 0.8 power factors
  • Generator set test report
  • CSA Certification
  • Torsional vibration analysis TVA report
  • Fuel consumption test

Starting / Charging Sytem

  • Jacket water heaters

Muffler

  • Industrial grade (15 dB)

Mounting System

  • Spring type vibration isolators
  • Puck style low efficiency isolators
  • Rubber
  • Spring vibration Isolators
  • Seismic rated vibration isolators

Controller

  • Cat ECS 200
  • EMCP 4.4

Controller attachments

  • Local annunciator module
  • Remote annuciator module
  • Expansion I/O module
  • Remote monitoring software

Telematics

  • Cellular

Extended service terms

  • 2 year (Prime)
  • 3 year
  • 5 year
  • 10 year

Extended service coverage

  • Silver
  • Gold
  • Platinum
  • Platinum plus

Alternator

  • Form wound
  • Permanent Magnet (PM) Excitation

Alternator Temperature rise (over 40°C ambient)

  • 80°C
  • 105°C
  • 125°C/130°C
  • 150°C

Alternator Output Voltage

  • 440V
  • 480V
  • 600V
  • 2400V
  • 4160V
  • 6300V
  • 6600V
  • 6900V
  • 12470V
  • 13200V
  • 13800V

Alternator attachments

  • Anti-condensation space heater
  • Stator and bearing temperature monitoring and protection

Power termination

  • Circuit breakers, IEC compliant
  • Circuit breakers, UL listed
  • Circuit breaker

Circuit breaker

  • 1600A
  • 2000A
  • 2500A
  • 3000A
  • 3200A
  • 4000A
  • 5000A
  • Electrically operated

Trip Unit

  • LSI
  • LSI-G
  • LSI-P
  • LSIG-P

Ancilliary Equipment

  • Automatic transfer switch (ATS)
  • Paralleling switchgear
  • Paralleling controls

Certifications

  • UL 2200
  • IBC seismic certification

Cat Switchgear

›
Cat Switchgear
ConfigurationIP4X
Operating Temperature35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)
Standard Widths600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.