Cat® 3516B (50 Hz) 2500 kVA with Upgradeable Package

3516B Generator Set

THE RUNDOWN

Cat® Diesel Engine
  • Rugged, durable design with reliable performance proven in thousands of applications worldwide
  • Certified alternative fuels including Hydrotreated Vegetable Oil (HVO), Renewable Diesel (RD) and Hydrotreated Renewable Diesel (HRD) which meet EN 15940 or ASTM D975 can be used or blended with EN 590 diesel
Cat Generator Set Package
  • Accepts 100% block load in one step
  • Meets NFPA 110 loading requirements
  • Conforms to ISO 8528-5 G3 load acceptance requirements
  • Reliability verified through torsional vibration, fuel consumption, oil consumption, transient performance, and endurance testing
Alternators
  • Superior motor starting capability minimizes need for oversizing generator
  • Designed to match performance and output characteristics of Cat diesel engines
Cooling System
  • Cooling systems are available to operate in ambient temperatures up to 50°C (122°F)
  • Tested to ensure proper generator set cooling
EMCP 4 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Warranty
  • 24 months/1000-hour warranty for Standby and Mission Critical ratings
  • 12 months/unlimited hour warranty for Prime and Continuous ratings
  • 12 months/unlimited hour warranty for Prime-DCP ratings
  • Extended service protection is available to provide extended coverage options
World Wide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Financing
  • Caterpillar offers an array of financial products to help you succeed through financial service excellence
  • Options include loans, finance lease, operating lease, working capital, and revolving line of credit
  • Contact your local Cat dealer for availability in your region
FAQ
  • Q. Does this generator comply with ISO 8528 guidelines? A. Yes, the 3516B, like Cat generators, is tested in accordance with the load steps outlined in with ISO 8528, Part 5.
  • Q. Are Cat generators easy to install? A. Cat generators can be configured with a number of options for ease of installation.
  • Q .Does Cat' have much experience with electric power generation? A. Cat has over 80 years’ experience with on-site and portable power and has shipped millions of generators to customers around the world.
  • Q. Does Cat offer generators that support my Sustainability goals? A. Cat offers generators that can run on a number of renewable fuels including HVO, biodiesel, landfill gas, sewage gas and more.
  • Q. Will this generator be able to provide emergency power on hot summer days? A. Most Cat 3500 Series generators can operate in ambient temperatures up to 50°C (122°F), reliably providing power when it is needed.
Generator Set Specifications
Standby Rating2500 kVA
Prime Power Rating2275 kVA
Emissions/Fuel StrategyLow Fuel, Low Emissions
Voltage380 to 415 Volts
Frequency50 Hz
Speed1500 rpm
Duty CycleStandby, Mission Critical, Prime, Continuous
Maximum Rating2500 kVA
Minimum Rating2000 kVA
Engine Specifications
Engine Model3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Bore6.69in
Stroke8.46in
Displacement4764.73in
Compression Ratio15.5:1
AspirationTA
Fuel SystemElectronic unit injection
Governor TypeAdem™3
Generator Set Dimensions
Length - Maximum247.3in
Width - Maximum90in
Height - Maximum98.2in
Dry Weight - Genset (maximum)34250lb
Standard Equipment

Air Inlet System

  • Air cleaner; single element canister type

Air Cleaner

  • Single element with service indicator

Starting

  • Standard electric starter(s)

Control Panels

  • 0 True RMS AC metering, 3-phase, +/-2% accuracy
  • Accessory module data link
  • Low oil pressure
  • 1 Programmable relay outputs (Form C)
  • Reverse power (kW) (32)
  • Warning/shutdown with common LED indication of shutdowns for:
  • Environmental sealed front face
  • Programmable protective relaying functions:
  • kW-hr (total)
  • Auto/start/stop control
  • Generator set packages include Caterpillar's voltage regulator (IVR). IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter. Limiter and exciter diode monitor
  • EMCP 4.2B
  • 6 Customer programmable digital inputs
  • Load histogram feature
  • Emergency stop pushbutton
  • Reverse reactive power (kVAr) (32RV)
  • Customizable screens
  • Low coolant level
  • PLC functionality
  • kVAr-hr (total)
  • Engine cycle crank
  • Coolant temperature
  • kVA (per phase, average & percent)
  • Controls:
  • High coolant temperature
  • Generator phase sequence
  • Over/under frequency (81 o/u)
  • Number of I/O varies on options selected
  • Low coolant temperature
  • Alarm acknowledge
  • Amps (per phase & average)
  • Cat connect
  • Overspeed
  • Engine cool-down timer
  • Operating hours
  • Oil pressure (psi, kPa or bar)
  • RPM
  • Power factor (per phase & average)
  • Serial annunciator module data link
  • 24 Volt DC operation
  • Overcurrent (50/51)
  • Generator mounted - rear facing
  • Over/under voltage (27/59)
  • 3 Analog inputs
  • 4 Programmable relay outputs (Form A)
  • Text alarm/event descriptions
  • kVAr (per phase, average & percent)
  • Customer data link (Modbus RTU)
  • Frequency (Hz)
  • Volts (L-L & L-N)
  • DC volts
  • Lamp test

Cooling

  • ATAAC
  • Standard Ambient Radiator

Crankcase Ventilation System

  • Non filtered crankcase ventilation

Cooling System

  • Certified standard PGS provided

Exhaust System

  • Flanged faced outlet(s)
  • Dry exhaust manifold

Fuel System

  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines - shipped loose
  • Secondary fuel filters
  • Fuel priming pump

General

  • Flywheel and flywheel housing - SAE No. 00
  • SAE standard rotation
  • Caterpillar yellow with high gloss black rails and radiator
  • Right hand servicing

Mounting System

  • Rails
  • Rails - Engine/generator/radiator mounting
  • Rubber anti-vibration mounts - shipped loose
  • Anti-vibration mounts (shipped loose)

Generator and Attachments

  • Low voltage:
  • Busbar connections, right side extension box, bottom cable entry
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
  • NEMA standard hole pattern
  • Internal excitation (IE)
  • Random wound
  • Anti-condensation space heater
  • Winding temperature detectors
  • 6 Leads
  • High voltage:
  • Medium voltage:
  • 3 Phase brushless, Salient pole
  • Permanent magnet excitation (PMG)
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)

Governing System

  • ADEM A3

Literature

  • Parts book

Lubrication System

  • Oil drain lines and valve
  • Fumes disposal
  • Lubricating oil
  • Gear type lube oil pump
  • Integral lube oil cool

Controller

  • EMCP 4.2B

Starting System

  • Battery and battery rack w/cables
  • 24 Volt electric starting motor
  • 45 Amp Charging alternator
  • Battery disconnect switch

Telematics

  • Ethernet

Alternator

  • Random wound
  • Internal excitation (IE)

Power Termination

  • Busbar
Optional Equipment

Control System

  • EMCP 4.4
  • Local annunciator module: [ ] NFPA 110 [ ] Custom

Engine Options

  • Starting aids: 220V 50 Hz Jacket water heater
  • Batteries: [ ] Standard (1400 CCA) [ ] Heavy Duty (2800 CCA)
  • Starting motors: [ ] Standard [ ] Heavy duty
  • Air cleaner: [ ] Single element air cleaners [ ] Dual element air cleaners [ ] Heavy duty air cleaners
  • Muffler: [ ] Industrial Grade
  • Battery charger: [ ] 10A [ ] 20A [ ] 35A

Air Inlet System

  • Single element filter
  • Dual element air cleaner

Cooling System

  • Coolant
  • Standard ambient ATAAC radiators
  • Water level switch gauges
  • Standard ambient radiators
  • Optional installed ATAAC radiators
  • Optional installed radiators

Air Cleaner

  • Dual element with service indicator
  • Heavy duty

Crankcase System

  • Ventilation system
  • No explosion relief valves
  • Explosion relief valves

Alternators

  • Temperature rise (over 40�C ambient): [ ] 150�C [ ] 125�C [ ] 105�C [ ] 80�C

Power Termination

  • Circuit breaker rating: [ ] 2000A [ ] 2500A [ ] 3200A [ ] 4000A
  • Power Termination: Busbar, Circuit breaker
  • Circuit breaker trip unit: [ ] LSI [ ] LSIG [ ] LSIG-P

Exhaust System

  • Y Adapters
  • Tier 4 clean emissions module
  • Clean emission parts
  • Exhaust offset
  • Elbows
  • Tier 4 clean emission MOD Kits
  • Flexible fittings
  • Tier 4 dosing cabinet
  • Mufflers
  • Flanges
  • Flange and exhaust expanders

Fuel System

  • Fuel priming pumps (Tier 4) - Manual or electric
  • Primary fuel filter

Extended Service Contract (ESC)

  • Extended Service Contract (ESC): [ ] 2 Year [ ] 3 Year [ ] 5 Year

General

  • US aid emblem
  • Special paint (Colors other than Caterpillar yellow or high performance paints)

Generators and Attachments

  • Generator conversion
  • Space heater
  • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
  • Differential current transformers (DCT) 8.7 kV and 15 kV classes
  • Thermostat for space heater
  • Alternator air cleaner
  • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame

Starting

  • Standard batteries
  • Oversized batteries
  • Battery charger - 10A
  • Battery charger - 20A
  • Battery charger - 35A
  • Air starter(s)
  • Jacket water heater

Instrumentation

  • Pyrometer and Thermocouples

Lubrication System

  • Prelube pumps
  • Lube oil in standard sump
  • Oil level regulator

Power Connections

  • Left side power connections
  • Rear power connections
  • Ground cables between generator and terminal box
  • 2700 Frame, four lead, four terminal
  • Neutral ground connections
  • Low voltage Circuit breakers
  • Center post busbars
  • Right side power connections

Cooling

  • No Radiator
  • High Ambient Radiator

Special Tests / Reports

  • Torsional vibration analysis reports
  • PGS Test report @ 0.8 power factor
  • Standard engine test charge
  • Generator set fuel consumption test
  • OSHPD Certification
  • PGS Test report @ 1.0 power factor
  • Generator test report
  • Fuel consumption test
  • IBC Certification
  • Canadian Standards Association certification

Crankcase Ventilation System

  • Filtered crankcase ventilation
  • Closed filtered crankcase ventilation

Starting and Charging

  • Jacket water heaters
  • Electric starting motors
  • Starter cover
  • Air pressure regulator
  • Engine barring device
  • Air starting motors
  • 24 Volt battery set - Dry
  • 10, 20, 35 and 50 Amp Battery chargers

Muffler

  • Industrial grade (15 dB)
  • Critical grade (25 dB)
  • Hospital grade (35 dB)

Mounting System

  • IBC vibration isolators
  • Puck style low efficiency isolators
  • Spring type vibration isolators
  • Spring vibration Isolators
  • Seismic rated vibration isolators

Controller

  • EMCP 4.3
  • EMCP 4.4

Controller attachments

  • Local annunciator module
  • Remote annuciator module
  • Expansion I/O module
  • Remote monitoring software

Telematics

  • Cellular

Extended service terms

  • 2 year (prime)
  • 3 year
  • 5 year
  • 10 year

Extended service coverage

  • Platinum, Gold and Silver coverage
  • Silver
  • Gold
  • Platinum
  • Platinum plus

Alternator

  • Form wound
  • Permanent Magnet (PM) Excitation

Alternator Temperature rise (over 40°C ambient)

  • 80°C
  • 105°C
  • 125°C/130°C
  • 150°C

Alternator Output Voltage

  • 380V
  • 400V
  • 415V
  • 6300V
  • 6600V
  • 6900V
  • 10000V
  • 10500V
  • 11000V

Alternator attachments

  • Anti-condensation space heater
  • Stator and bearing temperature monitoring and protection

Circuit breaker

  • 2000A
  • 2500A
  • 3200A
  • 4000A
  • IEC
  • 3-pole
  • Electrically operated

Trip Unit

  • LSI
  • LSI-G
  • LSIG-P

Ancilliary Equipment

  • Automatic transfer switch (ATS)
  • Paralleling switchgear
  • Paralleling controls

Certifications

  • EU & GB Declaration of Conformity
  • EU & GB Declaration of Incorporation
  • Eurasian Conformity (EAC)
  • Telecommunication Lab of China

Cat Switchgear

›
Cat Switchgear
ConfigurationIP4X
Operating Temperature35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)
Standard Widths600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.