3516B (60 Hz) with Upgradeable Package

3516B (60 Hz) with Upgradeable Package

THE RUNDOWN

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
EMCP 4 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirements
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Single-Source Supplier
  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Generator Set Specifications
Standby Rating2250 ekW
Prime Power Rating1825 ekW
Emissions/Fuel StrategyLow fuel, Low Emissions
Voltage380 to 480 Volts
Frequency60 Hz
Speed1800 rpm
Duty CycleStandby, Mission Critical, Prime, Continuous
Maximum Rating2250 ekW
Minimum Rating1640 ekW
Engine Specifications
Engine Model3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Bore6.69in
Stroke7.48in
Displacement4210.64in
Compression Ratio14.0:1
AspirationTA
Fuel SystemMEUI
Governor TypeADEM™ A4
Generator Set Dimensions
Length - Maximum234.5in
Width - Maximum90in
Height - Maximum98.2in
Dry Weight - Genset (maximum)30310lb
Standard Equipment

Air Inlet System

  • Air cleaner; single element canister type

Control Panels

  • PLC functionality
  • Oil pressure (psi, kPa or bar)
  • Text alarm/event descriptions
  • KVAR/PF modes
  • Cat connect
  • Overspeed
  • Amps (per phase & average)
  • Programmable protective relaying functions:
  • DC volts
  • EMCP 4.2B
  • Power factor (per phase & average)
  • Reverse reactive power (kVAr) (32RV) - Overcurrent (50/51)
  • Load histogram feature
  • Generator set packages include:
  • Frequency (Hz)
  • Emergency stop pushbutton
  • Over/under voltage (27/59)
  • RFI suppression
  • 24 Volt DC operation
  • Low coolant level
  • Reverse power (kW) (32) - Reverse reactive power (kVAr) (32RV) - Overcurrent (50/51)
  • 4 Programmable relay outputs (Form A)
  • Volts (L-L & L-N)
  • Caterpillar's voltage regulator
  • IVR includes:
  • Auto/start/stop control
  • kVA (per phase, average & percent)
  • Lamp test
  • Over/under frequency (81 o/u)
  • Environmental sealed front face
  • 3 Phase voltage sensing
  • Engine cool
  • kVAr-hr (total)
  • Low oil pressure
  • Accessory module data link
  • Emergency stop
  • Customer data link (Modbus RTU)
  • Communications:
  • Warning/shutdown with common LED indication of shutdowns for:
  • 0 True RMS AC metering, 3-phase, +/-2% accuracy
  • Digital indication for:
  • Customizable screens
  • Failure to start (overcrank)
  • Serial annunciator module data link
  • Coolant temperature
  • Controls:
  • Overcurrent (50/51)
  • Number of I/O varies on options selected
  • Reactive droop capability
  • Low coolant temperature
  • High coolant temperature
  • Min / max exciter
  • Alarm acknowledge
  • RPM
  • Generator phase sequence
  • Limiter and exciter diode monitor
  • Speed adjust
  • Operating hours
  • kW (per phase, average & percent)
  • 3 Analog inputs
  • Generator mounted - rear facing
  • 6 Customer programmable digital inputs

Lubrication System

  • Oil filter, filler and dipstick
  • Oil drain lines and valve
  • Gear type lube oil pump
  • Fumes disposal
  • Lubricating oil

Mounting System

  • Rubber anti-vibration mounts - shipped loose
  • Rails - engine/generator/radiator mounting
  • Anti-vibration mounts (shipped loose)

Starting System

  • 45 Amp Charging alternator
  • 24 Volt electric starting motor
  • Battery and battery rack w/cables
  • Battery disconnect switch

Literature

  • Parts book
  • Operation & Maintenance Manual
Optional Equipment

Control System

  • EMCP 4.3, EMCP 4.4

Air Inlet System

  • Dual element air cleaner
  • Single element filter

Cooling System

  • Water level switch gauges
  • Optional installed ATAAC radiators
  • Standard ambient ATAAC radiators
  • Standard ambient radiators
  • Coolant
  • Optional installed radiators

Crankcase System

  • Explosion relief valves
  • No explosion relief valves
  • Ventilation system

Exhaust System

  • Elbows
  • Flange and exhaust expanders
  • Tier 4 clean emissions module
  • Tier 4 clean emission MOD Kits
  • Clean emission parts
  • Exhaust offset
  • Mufflers
  • Tier 4 dosing cabinet
  • Flanges
  • Flexible fittings
  • Y Adapters

Fuel System

  • Fuel priming pumps (Tier 4) - Manual or electric
  • Primary fuel filter

General

  • US aid emblem
  • Special paint (Colors other than Caterpillar yellow or high performance paints)

Generators and Attachments

  • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
  • Generator conversion
  • Differential current transformers (DCT)
  • Differential current transformers (DCT) 8.7 kV and 15 kV classes
  • Low / Medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
  • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
  • Thermostat for space heater
  • Space heater
  • High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
  • Alternator air cleaner
  • High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
  • Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame

Instrumentation

  • Pyrometer and Thermocouples

Lubrication System

  • Oil level regulator
  • Prelube pumps
  • Lube oil in standard sump

Mounting System

  • Puck style low efficiency isolators
  • Spring type vibration isolators
  • IBC vibration isolators

Power Connections

  • Right side power connections
  • Ground cables between generator and terminal box
  • Neutral ground connections
  • Low voltage Circuit breakers
  • 2700 Frame, four lead, four terminal
  • Rear power connections
  • Left side power connections
  • Center post busbars

Special Tests / Reports

  • PGS Test report @ 0.8 power factor
  • PGS Test report @ 1.0 power factor
  • Fuel consumption test
  • Canadian Standards Association certification
  • Torsional vibration analysis reports
  • IBC Certification
  • Generator test report
  • Generator set fuel consumption test
  • OSHPD Certification
  • Standard engine test charge

Starting and Charging

  • Engine barring device
  • Air pressure regulator
  • Starter cover
  • Electric starting motors
  • Jacket water heaters
  • Air starting motors
  • 24 Volt battery set - Dry
  • 10, 20, 35 and 50 Amp Battery chargers

Extended Service Coverage

  • Platinum, Gold and Silver coverage

Cat Switchgear

Cat Switchgear
ConfigurationIP4X
Operating Temperature35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)
Standard Widths600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.