3516 Diesel Generator Set
THE RUNDOWN
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
EMCP 4 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirements
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Designed to operate in standard ambient temperatures up to 50°C (122°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
- IBC Seismic Certification
- EU Declaration of Conformity
- EEC Declaration of Incorporation
- Eurasian Conformity (EAC)
One Safe Source
- Components used in the generator set are selected at the design stage to provide optimum package performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Cat® Diesel Engine
- Rugged, durable design with reliable performance proven in thousands of applications worldwide
- Certified alternative fuels including Hydrotreated Vegetable Oil (HVO), Renewable Diesel (RD) and Hydrotreated Renewable Diesel (HRD) which meet EN 15940 or ASTM D975 can be used or blended with EN 590 diesel
Cat Generator Set Package
- Accepts 100% block load in one step
- Meets NFPA 110 loading requirements
- Conforms to ISO 8528-5 G3 load acceptance requirements
- Reliability verified through torsional vibration, fuel consumption, oil consumption, transient performance, and endurance testing
Alternators
- Superior motor starting capability minimizes need for oversizing generator
- Designed to match performance and output characteristics of Cat diesel engines
Cooling System
- Cooling systems are available to operate in ambient temperatures up to 50°C (122°F)
- Tested to ensure proper generator set cooling
EMCP 4 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Warranty
- 24 months/1000-hour warranty for Standby and Mission Critical ratings
- 12 months/unlimited hour warranty for Prime and Continuous ratings
- 12 months/unlimited hour warranty for Prime-DCP ratings
- Extended service protection is available to provide extended coverage options
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Financing
- Caterpillar offers an array of financial products to help you succeed through financial service excellence
- Options include loans, finance lease, operating lease, working capital, and revolving line of credit
- Contact your local Cat dealer for availability in your region
Generator Set Specifications
| Standby Rating | 2000 kVA |
| Prime Power Rating | 1825 kVA |
| Emissions/Fuel Strategy | Low Fuel Consumption |
| Voltage | 380 to 11000 Volts |
| Frequency | 50 Hz |
| Speed | 1500 rpm |
| Duty Cycle | Standby, Mission Critical, Prime, Continuous |
| Maximum Rating | 2000 kVA |
| Minimum Rating | 1600 kVA |
Engine Specifications
| Engine Model | 3516 TA, V-16, 4-Stroke Water-Cooled Diesel |
| Bore | 6.69in |
| Stroke | 7.48in |
| Displacement | 4210.64in³ |
| Compression Ratio | 13.0:1 |
| Aspiration | TA |
| Fuel System | Mechanical unit injection |
| Governor Type | Woodward |
Generator Set Dimensions
| Length - Minimum | 249.2in |
| Length - Maximum | 249.2in |
| Width - Minimum | 90in |
| Width - Maximum | 90in |
| Height - Minimum | 94.9in |
| Height - Maximum | 94.9in |
| Dry Weight - Genset (minimum) | 36750lb |
| Dry Weight - Genset (maximum) | 36750lb |
Standard Equipment
Air Inlet System
- Air cleaner; single element canister type
Air Inlet
- Air cleaner
Exhaust
- Exhaust flange outlet
Fuel
- Secondary fuel filters
- Fuel priming pump
- Primary fuel filter with integral water separator
Air Cleaner
- Single element with service indicator
Generator
- Matched to the performance and output characteristics of Cat engines
- IP23 Protection
Control Panel
- EMCP 4 Genset controller
Starting
- Dual electric starters
Control Panels
- Over/under voltage (27/59)
- Serial annunciator module data link
- Communications:
- Overcurrent (50/51)
- Over/under frequency (81 o/u
- Text alarm/event descriptions
- Generator set packages include Caterpillar's voltage regulator
- Programmable protective relaying functions:
- 4 Programmable relay outputs (Form A)
- Reverse power (kW) (32)
- Emergency stop
- Amps (per phase & average)
- Oil pressure (psi, kPa or bar)
- Operating hours
- 24 Volt DC operation
- Low oil pressure
- 6 Customer programmable digital inputs
- 1 Programmable digital outputs
- 1 Programmable relay outputs (Form C)
- Volts (L-L & L-N)
- Number of I/O varies on options selected
- RPM - DC volts
- Low coolant level
- kVAr-hr (total)
- Failure to start (overcrank)
- Environmental sealed front face
- Power factor (per phase & average)
- Accessory module data link
- Generator mounted - rear facing
- High coolant temperature
- Overspeed
- 3 Analog inputs
- Frequency (Hz)
- Warning/shutdown with common LED indication of shutdowns for
- Coolant temperature
- IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min /max exciter. Limiter and exciter diode monitor
- Customer data link (Modbus RTU)
- kVA (per phase, average & percent)
- Cat connect
- Generator phase sequence
- Reverse reactive power (kVAr) (32RV
- DC volts
- kW (per phase, average & percent)
- kVAr (per phase, average & percent)
- Emergency stop pushbutton
- Digital indication for:
- Low coolant temperature
- EMCP 4.2B
Cooling
- Package mounted radiator
- Standard Ambient Radiator
Cooling System
Exhaust System
- Flanged faced outlet(s)
- Dry exhaust manifold
Fuel System
- Flexible fuel lines - shipped loose
- Fuel priming pump
- Fuel cooler; not included with packages without radiator
- Secondary fuel filters
General
- SAE standard rotation
- Flywheel and flywheel housing - SAE No. 00
- Right hand servicing
- Caterpillar yellow with high gloss black rails and radiator
Generator and Attachments
- Medium voltage:
- Winding temperature detectors
- High voltage:
- 3 Phase brushless, Salient pole
- Permanent magnet excitation (PMG)
- Permanent magnet excitation (PMG)
- NEMA standard hole pattern
- Internal excitation (IE)
- Six lead
- Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
- Low voltage:
- Winding temperature detectors
- NEMA standard hole pattern
- Form wound
- Winding temperature detectors
- Random wound
- Busbar connections, top center mounted, top cable entry
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
- Anti-condensation space heater
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
Mounting System
- Rails
- Anti-vibration mounts (shipped loose)
- Rubber anti-vibration mounts - shipped loose
- Rails - Engine/generator/radiator mounting
Governing System
- ADEM A3
Literature
- Parts book
Lubrication System
- Gear type lube oil pump
- Fumes disposal
- Oil drain lines and valve
- Lubricating oil
- Oil filter, filler and dipstick
- Integral lube oil cool
Starting System
- Battery disconnect switch
- Battery and battery rack w/cables
- 45 Amp Charging alternator
- 24 Volt electric starting motor
Controller
- EMCP 4.2B
Telematics
- Ethernet
Alternator
- Random Wound
- Form Wound
- Internal Excitation (IE)
- Permanent Magnet (PM) Excitation
Power Termination
- Busbar
- Busbar
Optional Equipment
Air Inlet System
- Dual element air cleaner
- Single element filter
Exhaust
- Exhaust mufflers
Cooling System
- Optional installed radiators
- Coolant
- Standard ambient ATAAC radiators
- Optional installed ATAAC radiators
- Standard ambient radiators
- Water level switch gauges
Generator
- Internal excitation (IE)
- Anti-condensation heater
- Oversize and premium generators
- Permanent magnet excitation (PMG)
Crankcase System
- No explosion relief valves
- Ventilation system
- Explosion relief valves
Control Panels
- Remote monitoring software
- Generator temperature monitoring & protection
- Load share module
- Digital I/O module
- EMCP 4.2B
Air Cleaner
- Dual element with service indicator
Exhaust System
- Exhaust offset
- Tier 4 dosing cabinet
- Flexible fittings
- Mufflers
- Tier 4 clean emissions module
- Elbows
- Tier 4 clean emission MOD Kits
- Flanges
- Clean emission parts
- Y Adapters
Mounting
- Spring type vibration isolators
- IBC isolators
- Rubber anti-vibration mounts
Fuel System
- Fuel priming pumps (Tier 4) - Manual or electric
- Primary fuel filter
Starting/Charging
- Jacket water heater
- Oversize batteries
- Battery chargers
- Air starting motor with control and silencer
- Heavy duty starting system
- Charging alternator
General
- Special paint (Colors other than Caterpillar yellow or high performance paints)
- US aid emblem
Generators and Attachments
- Alternator air cleaner
- Differential current transformers (DCT) 8.7 kV and 15 kV classes
- Generator conversion
- Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
- Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
Instrumentation
Lubrication System
- Oil level regulator
- Prelube pumps
- Lube oil in standard sump
Starting
- Standard batteries
- Oversized batteries
- Battery charger - 10A
- Battery charger - 20A
- Battery charger - 40A
- Air starter(s)
- Jacket water heater
Power Connections
- Center post busbars
- Rear power connections
- 2700 Frame, four lead, four terminal
- Left side power connections
- Ground cables between generator and terminal box
- Low voltage Circuit breakers
Cooling
- High Ambient Radiator
Special Tests / Reports
- IBC Certification
- PGS Test report @ 1.0 power factor
- Generator test report
- Fuel consumption test
- Canadian Standards Association certification
- PGS Test report @ 0.8 power factor
- OSHPD Certification
- Torsional vibration analysis reports
- Generator set fuel consumption test
Starting and Charging
- Electric starting motors
- Air pressure regulator
- 24 Volt battery set - Dry
- Engine barring device
- Starter cover
- Air starting motors
- Jacket water heaters
- 10, 20, 35 and 50 Amp Battery chargers
Muffler
- Industrial grade (15 dB)
Mounting System
- Spring type vibration isolators
- IBC vibration isolators
- rubber
- Spring vibration Isolators
- Seismic rated vibration isolators
Controller attachments
- Local annunciator module
- Remote annuciator module
- Expansion I/O module
- Remote monitoring software
Telematics
- Cellular
Extended service terms
- 2 year (Prime)
- 3 year
- 5 year
- 10 year
Extended service coverage
- Platinum, Gold and Silver coverage
- Silver
- Gold
- Platinum
- Platinum plus
Alternator Temperature rise (over 40°C ambient)
- 80°C
- 105°C
- 125°C/130°C
- 150°C
Alternator Output Voltage
- 380V
- 400V
- 415V
- 3300V
- 6300V
- 6600V
- 6900V
- 10000V
- 10500V
- 11000V
Alternator attachments
- Anti-condensation space heater
- Stator and bearing temperature monitoring and protection
Power termination
- Circuit breakers, UL listed
- Circuit breakers, IEC compliant
- Circuit breaker
Circuit breaker
- 2500A
- 3000A
- 3200A
- 4000A
- 5000A
- IEC
- UL
- 3-pole
- 4-pole
- Manually operated
- Electrically operated
Trip Unit
- LSI
- LSI-G
- LSI-P
- LSIG-P
Ancilliary Equipment
- Automatic transfer switch (ATS)
- Paralleling switchgear
- Paralleling controls
Certifications
- IBC seismic certification
- Eurasian Conformity (EAC)