Cat® 3516 (60 Hz) with Upgradeable Package

3516 Diesel Generator Set

THE RUNDOWN

Cat® Diesel Engine
  • Rugged, durable design with reliable performance proven in thousands of applications worldwide
  • Certified alternative fuels including Hydrotreated Vegetable Oil (HVO), Renewable Diesel (RD) and Hydrotreated Renewable Diesel (HRD) which meet EN 15940 or ASTM D975 can be used or blended with EN 590 diesel
Cat Generator Set Package
  • Accepts 100% block load in one step
  • Meets NFPA 110 loading requirements
  • Conforms to ISO 8528-5 G3 load acceptance requirements
  • Reliability verified through torsional vibration, fuel consumption, oil consumption, transient performance, and endurance testing
Alternators
  • Superior motor starting capability minimizes need for oversizing generator
  • Designed to match performance and output characteristics of Cat diesel engines
Cooling System
  • Cooling systems are available to operate in ambient temperatures up to 50°C (122°F)
  • Tested to ensure proper generator set cooling
EMCP 4 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Warranty
  • 24 months/1000-hour warranty for Standby and Mission Critical ratings
  • 12 months/unlimited hour warranty for Prime and Continuous ratings
  • 12 months/unlimited hour warranty for Prime-DCP ratings
  • Extended service protection is available to provide extended coverage options
World Wide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Financing
  • Caterpillar offers an array of financial products to help you succeed through financial service excellence
  • Options include loans, finance lease, operating lease, working capital, and revolving line of credit
  • Contact your local Cat dealer for availability in your region
Generator Set Specifications
Standby Rating1750 ekW
Prime Power Rating1600 ekW
Emissions/Fuel StrategyLow Fuel Consumption
Voltage380 to 480 Volts
Frequency60 Hz
Speed1800 rpm
Duty CycleStandby, Mission Critical, Prime, Continuous
Maximum Rating1750 ekW
Minimum Rating1450 ekW
Engine Specifications
Engine Model3516 TA, V-16, 4-Stroke Water-Cooled Diesel
Bore6.69in
Stroke7.48in
Displacement4210.64in³
Compression Ratio13.5:1
AspirationTA
Fuel SystemMechanical unit injection
Governor TypeWoodward
Generator Set Dimensions
Length - Maximum234.4in
Width - Maximum90in
Height - Maximum94.9in
Dry Weight - Genset (maximum)28840lb
Standard Equipment

Air Inlet System

  • Air cleaner; single element canister type

Air Cleaner

  • Single element with service indicator

Control System

  • Auto/start/stop control
  • Engine cycle crank
  • Generator set packages include Caterpillar's voltage regulator
  • Speed adjust
  • IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min / max exciter. Limiter and exciter diode monitor
  • 24 Volt DC operation
  • Engine cool-down timer
  • Text alarm/event descriptions
  • Emergency stop pushbutton
  • Environmental sealed front face
  • EMCP 4.2B
  • Generator mounted - rear facing
  • Lamp test
  • Alarm acknowledge
  • PLC functionality
  • Load histogram feature
  • Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
  • ATAAC - 3516E package radiators shipped installed
  • 3 Analog inputs
  • 1 programmable digital outputs
  • Accessory module data link
  • 1 programmable relay outputs (Form C)
  • Cat connect
  • Reverse reactive power (kVAr) (32RV)
  • Number of I/O varies on options selected
  • 6 Customer programmable digital inputs
  • RPM
  • 4 programmable relay outputs (Form A)
  • Communications:
  • Overcurrent (50/51)
  • Volts (L-L & L-N)
  • Frequency (Hz)
  • Oil pressure (psi, kPa or bar) - Coolant temperature - Volts (L-L & L-N) - Frequency (Hz) - Amps (per phase & average) - Power factor (per phase & average) - kW (per phase, average & percent) - kVA (per phase, average & percent) - kVAr (per phase, average & percent) - kW-hr (total) - kVAr-hr (total)
  • Coolant temperature
  • kVAr (per phase, average & percent)
  • Amps (per phase & average)
  • kW (per phase, average & percent)
  • Power factor (per phase & average)
  • kW-hr (total)
  • kVAr-hr (total)
  • Warning/shutdown with common LED indication of shutdowns for:
  • Emergency stop
  • Failure to start (overcrank)
  • High coolant temperature
  • Low oil pressure
  • Overspeed
  • Programmable protective relaying functions
  • Low coolant level
  • Over/under voltage (27/59)
  • Generator phase sequence
  • Over/under frequency (81 o/u)
  • Reverse power (kW) (32)

Starting

  • Heavy duty electric starter(s)
  • Heavy duty electric starter(s)

Governing System

  • ADEM A3

Cooling

  • ATAAC
  • Standard Ambient Radiator
  • Standard Ambient Radiator

Crankcase Ventilation System

  • Non filtered crankcase ventilation

Exhaust System

  • Flanged faced outlet(s)
  • Dry exhaust manifold

Fuel System

  • Fuel priming pump
  • Flexible fuel lines - shipped loose
  • Fuel cooler; not included with packages without radiator
  • Secondary fuel filters

General

  • Caterpillar yellow with high gloss black rails and radiator
  • SAE standard rotation
  • Right hand servicing
  • Flywheel and flywheel housing - SAE No. 00

Mounting System

  • Rails
  • Rails
  • Rubber anti-vibration mounts - shipped loose
  • Rails - Engine/generator/radiator mounting

Generator and Attachments

  • Winding temperature detectors
  • High voltage:
  • Form wound
  • Random wound
  • Busbar connections, top center mounted, top cable entry
  • Permanent magnet excitation (PMG)
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
  • Anti-condensation space heater
  • NEMA standard hole pattern
  • Permanent magnet excitation (PMG)
  • Winding temperature detectors
  • 3 Phase brushless, Salient pole
  • Six lead
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
  • Low voltage:
  • Internal excitation (IE)
  • Medium voltage:
  • NEMA standard hole pattern
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby
  • Winding temperature detectorsle pattern
  • Busbar connections, right side extension box, bottom cable entry

Literature

  • Parts book
  • Operation & Maintenance Manual

Lubrication System

  • Oil drain lines and valve
  • Lubricating oil
  • Gear type lube oil pump
  • Integral lube oil cool
  • Fumes disposal

Controller

  • EMCP 4.2B

Starting System

  • Battery disconnect switch
  • 24 Volt electric starting motor
  • Battery and battery rack w/cables
  • 45 Amp Charging alternator

Telematics

  • Ethernet
  • Ethernet

Alternator

  • Random wound
  • Random Wound
  • Internal excitation (IE)
  • Internal Excitation (IE)

Power Termination

  • Busbar
  • Busbar
Optional Equipment

Control System

  • EMCP 4.3, EMCP 4.4
  • Local annunciator module: [ ] NFPA 110 [ ] Custom

Air Inlet System

  • Dual element air cleaner
  • Single element filter

Cooling System

  • Standard ambient radiators
  • Standard ambient ATAAC radiators
  • Optional installed ATAAC radiators
  • Coolant
  • Optional installed radiators
  • Water level switch gauges

Engine Options

  • Starting motors: [ ] Standard [ ] Heavy duty
  • Muffler: [ ] Industrial Grade
  • Air cleaner: [ ] Single element air cleaners [ ] Dual element air cleaners [ ] Heavy duty air cleaners
  • Starting aids: [ ] 220V 50 Hz Jacket water heater
  • Batteries: [ ] Standard (1400 CCA) [ ] Heavy Duty (2800 CCA)

Crankcase System

  • Ventilation system
  • No explosion relief valves
  • Explosion relief valves

Air Cleaner

  • Dual element with service indicator
  • Dual element with service indicator
  • Heavy duty

Alternators

  • Temperature rise (over 40°C ambient): [ ] 150°C [ ] 125°C [ ] 105°C [ ] 80°C

Exhaust System

  • Y Adapters
  • Flanges
  • Exhaust offset
  • Clean emission parts
  • Tier 4 clean emissions module
  • Flexible fittings
  • Mufflers
  • Tier 4 clean emission MOD Kits
  • Elbows
  • Tier 4 dosing cabinet

Fuel System

  • Fuel priming pumps (Tier 4) - Manual or electric

General

  • Special paint (Colors other than Caterpillar yellow or high performance paints)
  • The following options are based on regional and product configuration:
  • UL 2200 package
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007

Starting

  • Standard batteries
  • Dual electric starters
  • Oversized batteries
  • Standard batteries
  • Battery charger - 10A
  • Oversized batteries
  • Battery charger - 20A
  • Battery charger - 10A
  • Battery charger - 35A
  • Battery charger - 20A
  • Battery charger - 35A
  • Air starter(s)
  • Jacket water heater
  • Air starter(s)
  • Jacket water heater

Generators and Attachments

  • Alternator air cleaner
  • High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
  • Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame
  • Thermostat for space heater
  • Generator conversion
  • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
  • Differential current transformers (DCT)
  • Differential current transformers (DCT) 8.7 kV and 15 kV classes

Extended Service Contract (ESC)

  • Extended Service Contract (ESC): [ ] 2 Year [ ] 3 Year [ ] 5 Year

Instrumentation

Lubrication System

  • Prelube pumps
  • Lube oil in standard sump

Power Connections

  • Neutral ground connections
  • Center post busbars
  • Right side power connections
  • Rear power connections
  • Ground cables between generator and terminal box
  • Left side power connections
  • 2700 Frame, four lead, four terminal

Cooling

  • No Radiator
  • No Radiator
  • High Ambient Radiator
  • High Ambient Radiator

Special Tests / Reports

  • Generator test report
  • Fuel consumption test
  • Standard engine test charge
  • OSHPD Certification
  • Canadian Standards Association certification
  • PGS Test report @ 1.0 power factor
  • Generator set fuel consumption test
  • Torsional vibration analysis reports
  • PGS Test report @ 0.8 power factor

Crankcase Ventilation System

  • Filtered crankcase ventilation
  • Closed filtered crankcase ventilation

Starting and Charging

  • Electric starting motors
  • Air pressure regulator
  • Engine barring device
  • Starter cover
  • 10, 20, 35 and 50 Amp Battery chargers
  • 24 Volt battery set - Dry
  • Air starting motors

Muffler

  • Industrial grade (15 dB)
  • Industrial grade (15 dB)
  • Critical grade (25 dB)
  • Hospital grade (35 dB)

Mounting System

  • Puck style low efficiency isolators
  • Spring type vibration isolators
  • IBC vibration isolators
  • Rubber
  • Spring vibration Isolators
  • Spring vibration Isolators
  • Seismic rated vibration isolators
  • Seismic rated vibration isolators

Controller

  • EMCP 4.3
  • EMCP 4.3
  • EMCP 4.4
  • EMCP 4.4

Controller attachments

  • Local annunciator module
  • Local annunciator module
  • Remote annuciator module
  • Remote annuciator module
  • Expansion I/O module
  • Expansion I/O module
  • Remote monitoring software
  • Remote monitoring software

Telematics

  • Cellular
  • Cellular

Extended service terms

  • 2 year (Prime)
  • 2 year (prime)
  • 3 year
  • 3 year
  • 5 year
  • 5 year
  • 10 year
  • 10 year

Extended service coverage

  • Platinum, Gold and Silver coverage
  • Silver
  • Silver
  • Gold
  • Gold
  • Platinum
  • Platinum
  • Platinum plus
  • Platinum plus

Alternator

  • Form wound
  • Permanent Magnet (PM) Excitation
  • Permanent Magnet (PM) Excitation

Alternator Temperature rise (over 40°C ambient)

  • 80°C
  • 105°C
  • 125°C/130°C
  • 80°C
  • 150°C
  • 105°C
  • 125°C
  • 150°C

Alternator Output Voltage

  • 416V
  • 480V
  • 600V
  • 4160V
  • 12470V
  • 380V
  • 13200V
  • 13800V
  • 480V

Alternator attachments

  • Anti-condensation space heater
  • Stator and bearing temperature monitoring and protection
  • Anti-condensation space heater
  • Stator and bearing temperature monitoring and protection

Power termination

  • Circuit breaker rating: [ ] 2000A [ ] 2500A [ ] 3200A [ ] 4000A
  • Circuit breaker operation: [ ] Electrical
  • Power termination: [ ] Busbar [ ] Circuit breaker
  • Circuit breaker trip unit: [ ] LSI [ ] LSIG [ ] LSIG-P
  • Circuit breaker

Circuit breaker

  • 1600A
  • 2000A
  • 2000A
  • 2500A
  • 2500A
  • 3200A
  • 3200A
  • 4000A
  • 4000A
  • IEC
  • Electrically operated
  • 3-pole
  • Manually operated
  • Electrically operated

Trip Unit

  • LSI
  • LSI
  • LSI-G
  • LSI-G
  • LSIG-P
  • LSIG-P

Ancilliary Equipment

  • Automatic transfer switch (ATS)
  • Automatic transfer switch (ATS)
  • Paralleling switchgear
  • Paralleling switchgear
  • Paralleling controls
  • Paralleling controls

Cat Switchgear

›
Cat Switchgear
ConfigurationIP4X
Operating Temperature35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)
Standard Widths600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.