3512C (1750 ekW, 60 Hz)

3512C Generator Set

THE RUNDOWN

Cat® Diesel Engine
  • Rugged, durable design with reliable performance proven in thousands of applications worldwide
  • Certified alternative fuels including Hydrotreated Vegetable Oil (HVO), Renewable Diesel (RD) and Hydrotreated Renewable Diesel (HRD) which meet EN 15940 or ASTM D975 can be used or blended with EN 590 diesel
Cat Generator Set Package
  • Accepts 100% block load in one step
  • Meets NFPA 110 loading requirements
  • Conforms to ISO 8528-5 G3 load acceptance requirements
  • Reliability verified through torsional vibration, fuel consumption, oil consumption, transient performance, and endurance testing
Alternators
  • Superior motor starting capability minimizes need for oversizing generator
  • Designed to match performance and output characteristics of Cat diesel engines
Cooling System
  • Cooling systems are available to operate in ambient temperatures up to 50°C (122°F)
  • Tested to ensure proper generator set cooling
Cat ECS Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirements
  • Expansion modules and site specific programming for specific customer requirements
  • Graphical touchscreen display
  • Easily upgradeable
Warranty
  • 24 months/1000-hour warranty for Standby and Mission Critical ratings
  • 12 months/unlimited hour warranty for Prime and Continuous ratings
  • 12 months/unlimited hour warranty for Prime-DCP ratings
  • Extended service protection is available to provide extended coverage options
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Financing
  • Caterpillar offers an array of financial products to help you succeed through financial service excellence
  • Options include loans, finance lease, operating lease, working capital, and revolving line of credit
  • Contact your local Cat dealer for availability in your region
Generator Set Specifications
Standby Rating1750 ekW
Prime Power Rating1600 ekW
Emissions/Fuel StrategyU.S. EPA Cert., Tier 2
Voltage380 to 13800 Volts
Frequency60 Hz
Speed1800 rpm
Duty CycleStandby, Mission Critical
Maximum Rating1750 ekW
Minimum Rating1600 ekW
Engine Specifications
Engine Model3512C ATAAC, V-12, 4-Stroke Water-Cooled Diesel
Bore6.69in
Stroke8.46in
Displacement3574in³
Compression Ratio14.7:1
AspirationTA
Fuel SystemElectronic unit injection
Governor TypeADEM™ A3
Generator Set Dimensions
Length - Minimum231.3in
Length - Maximum231.3in
Width - Minimum89.7in
Width - Maximum89.7in
Height - Minimum104.4in
Height - Maximum104.4in
Dry Weight - Genset (minimum)31837lb
Dry Weight - Genset (maximum)31837lb
Standard Equipment

Air Inlet System

  • Air cleaner; single element canister type with service indicator

Exhaust

  • Exhaust flange outlet

Fuel

  • Primary fuel filter with integral water separator
  • Fuel priming pump
  • Secondary fuel filters

Air Cleaner

  • Single element with service indicator

Generator

  • Matched to the performance and output characteristics of Cat engines
  • IP23 Protection

Control Panel

  • Cat ECS Genset controller

Starting

  • Heavy duty electric starter(s)

Control System

  • Generator set packages include Caterpillar's voltage regulator (IVR). IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min/max exciter. Limiter and exciter diode monitor
  • Emergency stop pushbutton
  • Oil pressure (psi, kPa or bar)
  • 1 Programmable digital outputs
  • Accessory module data link
  • 4 Programmable relay outputs (Form A)
  • kVAr-hr (total)
  • Reverse power (kW) (32)
  • kVAr (per phase, average & percent)
  • Amps (per phase & average)
  • Over/under frequency (81 o/u)
  • Cat ECS 100
  • PLC functionality
  • 1 Programmable relay outputs (Form C)
  • Programmable protective relaying functions:
  • RPM
  • Frequency (Hz)
  • Low coolant level
  • Number of I/O varies on options selected
  • Lamp test
  • kVA (per phase, average & percent)
  • Emergency stop
  • kW (per phase, average & percent)
  • Engine cool-down timer
  • Speed adjust
  • Generator phase sequence
  • Over/under voltage (27/59)
  • Warning/shutdown with common LED indication of shutdowns for:
  • Customer data link (Modbus RTU)
  • Volts (L-L & L-N)
  • High coolant temperature
  • Engine cycle crank
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Low coolant temperature
  • Low oil pressure
  • Cat connect
  • Digital indication for:
  • Communications
  • Environmental sealed front face
  • Reverse reactive power (kVAr) (32RV)
  • 24 Volt DC operation
  • Power factor (per phase & average)
  • Overspeed
  • Auto/start/stop control
  • Load histogram feature
  • Controls:
  • Failure to start (overcrank)
  • Customizable screens
  • kW-hr (total)
  • Text alarm/event descriptions
  • Alarm acknowledge
  • Overcurrent (50/51)
  • Generator mounted - rear facing
  • Coolant temperature
  • DC volts

Governing System

  • ADEM III

Cooling

  • Package mounted radiator
  • Standard Ambient Radiator

Cooling System

  • SCAC
  • Fan and belt guards
  • Caterpillar extended life coolant (Not included with packages without radiator, installed SF44CTS
  • Coolant level sensors (Not included with packages without radiator)
  • Radiator fan and fan drive
  • Coolant drain line with valve

Exhaust System

  • Flanged faced outlet(s)
  • Dry exhaust manifold

Fuel System

  • Secondary fuel filters
  • Fuel priming pump
  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines - shipped loose

Mounting System

  • Rails
  • Rubber anti-vibration mounts - shipped loose

Generators and Attachments

  • Random wound
  • Permanent magnet excitation (PMG)
  • High voltage
  • Six lead
  • NEMA standard hole pattern
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
  • NEMA standard hole pattern
  • Winding temperature detectors
  • NEMA standard hole pattern
  • Internal excitation (IE)
  • Form wound
  • 3 Phase brushless, Salient pole
  • Busbar connections, right side extension box, bottom cable entry
  • Low voltage:
  • Busbar connections, top center mounted, top cable entry
  • Medium voltage:

Literature

  • Parts book

Lube System

  • Oil drain lines and valve
  • Lubricating oil
  • Oil filter, filler and dipstick
  • Fumes disposal
  • Gear type lube oil pump
  • Integral lube Oil cooler

Starting / Charging System

  • Battery and battery rack w/cables
  • 45 Amp Charging alternator
  • 24 Volt electric starting motor
  • Battery disconnect switch

Controller

  • Cat ECS 100

General

  • Paint - Caterpillar yellow except rails and radiators gloss black
  • SAE standard rotation
  • Right hand servicing
  • Flywheel and Flywheel housing-SAE No. 00
  • Paint - Caterpillar yellow with high gloss black rails & radiator

Telematics

  • Ethernet

Alternator

  • Random Wound
  • Permanent Magnet (PM) Excitation

Power Termination

  • Busbar
  • Busbar
Optional Equipment

Control Panels

  • Digital I/O module
  • EMCP 4.4
  • Load share module
  • Remote monitoring software
  • Generator temperature monitoring & protection

Exhaust

  • Exhaust mufflers

Air Inlet System

  • Heavy duty air cleaner
  • Single element filter

Generator

  • Permanent magnet excitation (PMG)
  • Anti-condensation heater
  • Internal excitation (IE)
  • Oversize and premium generators

Cooling System

  • Standard installed radiators
  • Standard installed ATAAC radiators
  • Optional installed ATAAC radiators
  • Water level switch gauges
  • Coolant
  • Optional installed radiators

Exhaust System

  • Flanges
  • Flange and exhaust expanders
  • Flexible fittings
  • Elbows
  • Y Adapters
  • Mufflers

Air Cleaner

  • Dual element with service indicator

Fuel System

  • Primary fuel filter

Starting/Charging

  • Heavy duty starting system
  • Charging alternator
  • Battery chargers
  • Oversize batteries
  • Air starting motor with control and silencer
  • Jacket water heater

Generators and Attachments

  • 1400, 1600, 2700 Frames
  • Space heater
  • Generator conversion from IE to PM
  • Differential current transformers (DCT) 15 kV class
  • RW, IE, 6 Leads, Pitch 0.6667
  • Generator air cleaner
  • Low voltage: 380,440 / 480 Volts, 3 Phase, 1800 rpm
  • Differential current transformers (DCT) 8.7 kV class

Instrumentation

  • Wiring GP W/O cyl sensors
  • Pyrometer and thermocouples

Lube System

  • Oil drains
  • Lubrication oil in standard sump
  • Oil level regulator
  • Prelube pumps

Starting

  • Dual electric starters
  • Standard batteries
  • Oversized batteries
  • Battery charger - 10A
  • Battery charger - 20A
  • Battery charger - 40A
  • Air starter(s)
  • Jacket water heater

General

  • US aid emblem
  • The following options are based on regional and product configuration:
  • Automatic transfer switches (ATS)
  • EU Certificate of Conformance (CE)
  • CSA Certification
  • Integral & sub-base UL listed dual wall fuel tanks
  • EEC Declaration of Conformity
  • UL 2200 package
  • Integral & sub-base fuel tanks
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • Enclosures: Sound attenuated, weather protective

Crankcase Protection

  • No crankcase explosion relief valves
  • Explosion relief valves
  • Crankcase ventilation system
  • No explosion relief valves

Mounting

  • IBC isolators
  • Rubber anti-vibration mounts
  • Spring type vibration isolators

Power Connections

  • 1600 ,2000, 2500, 3000, 4000 Amp, 3 Pole, UL-100% rated Circuit breakers
  • Grounding groups
  • Neutral ground connections
  • Right side power connections
  • Rear power connections
  • Left side power connections
  • Six lead, six terminal option
  • 2000, 2500, 3200 Amp, 3 Pole, IEC rated Circuit breakers
  • Center post busbars
  • 2000, 2500 Amp, 4 Pole, IEC rated Circuit breakers
  • Cable entry - right side

Cooling

  • High Ambient Radiator

Special Tests / Reports

  • Fuel consumption test
  • Generator test report
  • IBC seismic Certification
  • PGS Test report @ 1.0 power factor
  • Standard engine test charge
  • CSA Certification
  • Generator fuel consumption test
  • Torsional vibration analysis
  • PGS Test report @ 0.8 power factor

Starting / Charging System

  • 24 Volt battery set - Dry
  • Air pressure regulator
  • 10 Amp Battery charger
  • Air starting motor
  • 35 Amp Battery charger
  • Jacket water heaters
  • Starter cover
  • Engine barring device
  • Batteries, racks and cables:
  • Electric starting motors

Muffler

  • Industrial grade (15 dB)

Mounting System

  • Spring type vibration isolators
  • IBC vibration isolators
  • Puck style low efficiency isolators
  • Rubber
  • Spring vibration Isolators
  • Seismic rated vibration isolators

Controller

  • Cat ECS 200
  • EMCP 4.4

Controller attachments

  • Local annunciator module
  • Remote annuciator module
  • Expansion I/O module
  • Remote monitoring software

Telematics

  • Cellular

Extended service terms

  • 2 year (Prime)
  • 3 year
  • 5 year
  • 10 year

Extended service coverage

  • Silver
  • Gold
  • Platinum
  • Platinum plus

Alternator

  • Form wound

Alternator Temperature rise (over 40°C ambient)

  • 80°C
  • 105°C
  • 125°C/130°C
  • 150°C

Alternator Output Voltage

  • 380V
  • 416V
  • 480V
  • 600V
  • 4160V
  • 6300V
  • 6600V
  • 12470V
  • 13200V
  • 13800V

Alternator attachments

  • Anti-condensation space heater
  • Stator and bearing temperature monitoring and protection

Power termination

  • Circuit breakers, IEC compliant
  • Circuit breakers, UL listed
  • Circuit breaker

Circuit breaker

  • 1600A
  • 2000A
  • 2500A
  • 3000A
  • 3200A
  • 4000A
  • Electrically operated

Trip Unit

  • LSI
  • LSI-G
  • LSI-P
  • LSIG-P

Ancilliary Equipment

  • Automatic transfer switch (ATS)
  • Paralleling switchgear
  • Paralleling controls

Certifications

  • UL 2200
  • IBC seismic certification
  • HCAI/OSHPD OSP preapproved

Cat Switchgear

›
Cat Switchgear
ConfigurationIP4X
Operating Temperature35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)
Standard Widths600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.