3512B Diesel Generator Set
THE RUNDOWN
Cat® Diesel Engine
- Rugged, durable design with reliable performance proven in thousands of applications worldwide
- Certified alternative fuels including Hydrotreated Vegetable Oil (HVO), Renewable Diesel (RD) and Hydrotreated Renewable Diesel (HRD) which meet EN 15940 or ASTM D975 can be used or blended with EN 590 diesel
Cat Generator Set Package
- Accepts 100% block load in one step
- Meets NFPA 110 loading requirements
- Conforms to ISO 8528-5 G3 load acceptance requirements
- Reliability verified through torsional vibration, fuel consumption, oil consumption, transient performance, and endurance testing
Alternators
- Superior motor starting capability minimizes need for oversizing generator
- Designed to match performance and output characteristics of Cat diesel engines
Cooling System
- Cooling systems are available to operate in ambient temperatures up to 50°C (122°F)
- Tested to ensure proper generator set cooling
EMCP 4 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Warranty
- 24 months/1000-hour warranty for Standby and Mission Critical ratings
- 12 months/unlimited hour warranty for Prime and Continuous ratings
- 12 months/unlimited hour warranty for Prime-DCP ratings
- Extended service protection is available to provide extended coverage options
World Wide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Financing
- Caterpillar offers an array of financial products to help you succeed through financial service excellence
- Options include loans, finance lease, operating lease, working capital, and revolving line of credit
- Contact your local Cat dealer for availability in your region
Generator Set Specifications
| Standby Rating | 1500/1400 kW |
| Prime Power Rating | 1360/1275 kW |
| Emissions/Fuel Strategy | Low Fuel, Low Emissions |
| Voltage | 380 to 480 Volts |
| Frequency | 60 Hz |
| Speed | 1800 rpm |
| Duty Cycle | Standby, Mission Critical, Prime, Continuous |
| Maximum Rating | 1500 kW |
| Minimum Rating | 1230 kW |
Engine Specifications
| Engine Model | 3512B TA, V-12, 4-Stroke Water-Cooled Diesel |
| Bore | 6.69in |
| Stroke | 7.48in |
| Displacement | 51.8in³ |
| Compression Ratio | 14.0:1 Std 15.5:1 HD |
| Aspiration | TA |
| Fuel System | Electronic Unit Injection |
| Governor Type | ADEM™ A3 |
Generator Set Dimensions
| Length - Maximum | 207.8in |
| Width - Maximum | 90in |
| Height - Maximum | 94.9in |
| Dry Weight - Genset (minimum) | 24297lb |
| Dry Weight - Genset (maximum) | 24959lb |
Standard Equipment
Air Inlet System
- Air cleaner; single element canister type with service indicator
Air Cleaner
- Single element with service indicator
Control System
Starting
- Heavy duty electric starter(s)
Control Panel
- 24 Volt DC operation
- kVA (per phase, average & percent)
- Engine cool-down timer
- Coolant temperature
- kW-hr (total)
- Amps (per phase & average)
- Over/under frequency (81 o/u)
- Text alarm/event descriptions
- Alarm acknowledge
- Warning/shutdown with common LED indication of shutdowns for:
- Auto/start/stop control
- Controls:
- Failure to start (overcrank)
- Generator mounted - rear facing
- kVAr (per phase, average & percent)
- kVAr-hr (total)
- Reverse reactive power (kVAr) (32RV)
- Volts (L-L & L-N)
- Serial annunciator module data link
- 4 programmable relay outputs (Form A)
- Lamp test
- Operating hours
- Overcurrent (50/51)
- kW (per phase, average & percent)
- Communications:
- 6 programmable digital inputs
- RPM
- Engine cycle crank
- 2 Programmable relay outputs (Form C)
- IVR includes reactive droop capability, 3-phase voltage sensing
- High coolant temperature
- Digital indication for:
- Environmental sealed front face
- Power factor (per phase & average)
- Speed adjust
- Emergency stop pushbutton
- Limiter and exciter diode monitor
- Low oil pressure
- EMCP 4.2B
- Low coolant level
- 2 Programmable digital outputs
- KVAR/PF modes, RFI suppression, min/max exciter
- Oil pressure (psi, kPa or bar)
- Customer data link (Modbus RTU)
- True RMS AC metering, 3-phase, +/-2% accuracy
- Overspeed
- Frequency (Hz)
- Emergency stop
- Generator set packages include Caterpillar's voltage regulator (IVR)
- Reverse power (kW) (32)
- Low coolant temperature
- Generator phase sequence
- Programmable protective relaying functions:
- Over/under voltage (27/59)
Cooling
- Standard Ambient Radiator
Cooling System
- Caterpillar extended life coolant. (Not included with packages without radiator, installed SF44CTS, shipped loose radiators or heat exchangers)
- Fan and belt guards
- JWAC
- Coolant drain line with valve
- Coolant level sensors (Not included with packages without radiator)
Exhaust
- Dry exhaust manifold
- Flanged faced outlet(s)
Fuel System
- Fuel cooler; not included with packages without radiator
- Fuel priming pump
- Secondary fuel filters
- Flexible fuel lines - shipped loose
Generators and Attachments
- NEMA Class H insulation
- Winding temperature detectors
- Internal excitation (IE) or Permanent magnet excitation (PMG)
- LV
- 6 Lead
- 60 Hz models: NEMA standard hole pattern
- Class H temperature rise at 40C ambient (125C prime / 150C standby)
- 3 Phase brushless, Salient pole
- Busbar connections, top center mounted, top cable entry
- Random wound
Governing System
- Woodward 2301A isochronous governor
Lube System
- Oil drain lines and valve
- Integral lube Oil cooler
- Fumes disposal
- Gear type lube oil pump
- Oil filter, filler and dipstick
Mounting System
- Rails
- Rails - engine/generator/radiator mounting
- Rubber anti-vibration mounts - shipped loose
Starting / Charging System
- Battery disconnect switch
- Battery and battery rack w/cables
- 24-Volt electric starting motor
- 50 Amp Charging alternator
General
- SAE standard rotation
- Paint - Caterpillar yellow with high gloss black rails & radiator
- Flywheel and Flywheel housing-SAE No. 00
- RH service
Controller
- EMCP 4.2B
Telematics
- Ethernet
Alternator
- Random Wound
- Internal Excitation (IE)
Power Termination
- Busbar
Optional Equipment
Air Inlet System
- Air cleaner: Includes installed single element Cat filter and service indicator
- Dual element air filters
- Single stage air cleaners
Control Panels
- Cat connect (must choose one)
- RTD module - may select one
- Modbus monitoring of packages
- First local annunicator
- EMCP 4.3, EMCP 4.4
- CAN2 network equipment
- Remote custom annunciator
- Locale discrete I / O package
- Vandle proof panel door
Air Cleaner
- Dual element with service indicator
Cooling System
- Optional radiator arrangements
- Water level gauge
- Coolant
Control System
Exhaust System
- Exhaust Y Adapters
- Exhaust elbows
- Mufflers
- Flexible fittings
- Exhaust flange and expanders
Generators and Attachments
- Space heater control
- Generator conversion
- Space heater
Instrumentation
Starting
- Dual electric starters
- Standard batteries
- Oversized batteries
- Battery charger - 10A
- Battery charger - 20A
- Battery charger - 35A
- Jacket water heater
Lube System
- Oil level regulator
- Electric prelube sump pump
- Lube oil
Special Tests / Reports
- Generator test report
- Standard generator TVA report
- Custom generator TVA report
- Torsional vibration analysis
- PGS Test report @ 1.0 power factor
- Standard engine test charge
- Generator test report
- Standard engine test charge
- Generator fuel consumption test
General
- Barring devices
Crankcase System
- Ventilation system
- Protection systems
Batteries and Battery Housing
- 24 Volt battery set - Dry
Power Connection System
- EMCP voltage and current sensing groups
- Breaker power connections
- Center post busbars
Circuit breaker - LV Packages
- Right hand power connections
- Electronically operated circuit breakers
Power Connections
- Low voltage - Package mounted circuit breakers
- Low voltage - 1400 and 1600 Frame generators
- Low voltage - Power connection options
Cooling
- No Radiator
- High Ambient Radiator
Starting / Charging System
- Jacket water heater wiring groups
- 35 Amp Battery charger
- 20 Amp Battery charger
- Jacket water heaters
- 10 Amp Battery charger
- Electric starting motors
- Starter cover
- Batteries, racks and cables
Starting / Charging Systems
- Jacket water heater
- Electric starting motors
Muffler
- Industrial grade (15 dB)
Mounting System
- Low efficiency isolators
- Spring type vibration isolators
- Low efficiency isolators puck
- Rubber
- Spring vibration Isolators
- Seismic rated vibration isolators
Controller
- EMCP 4.3
- EMCP 4.4
Controller attachments
- Local annunciator module
- Remote annuciator module
- Expansion I/O module
- Remote monitoring software
Telematics
- Cellular
Extended service terms
- 2 year (Prime)
- 3 year
- 5 year
- 10 year
Extended service coverage
- Gold - 36,48, 60, 120 month coverage
- Cat branded commercial power system
- Platinum - 24, 36, 48, 60, 120 month coverage
- Silver
- Gold
- Platinum
- Platinum plus
Alternator
- Permanent Magnet (PM) Excitation
Alternator Temperature rise (over 40°C ambient)
- 80°C
- 105°C
- 125°C
- 150°C
Alternator Output Voltage
- 380V
- 480V
Alternator attachments
- Anti-condensation space heater
- Stator and bearing temperature monitoring and protection
Power termination
- Circuit breaker
Circuit breaker
- 1600A
- 2000A
- 2500A
- 3200A
- 4000A
- Electrically operated
Trip Unit
- LSI
- LSI-G
- LSIG-P
Ancilliary Equipment
- Automatic transfer switch (ATS)
- Paralleling switchgear
- Paralleling controls