3512B (50 Hz) with Upgradeable Package 1360 – 1600 kVA

3512B Diesel Generator Set

THE RUNDOWN

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
EMCP 4 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • EU Declaration of Conformity
  • EU Declaration of Incorporation
  • Eurasian Conformity (EAC)
  • Telecommunication Lab of China
One Safe Source
  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
World Wide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Cat® Diesel Engine
  • Rugged, durable design with reliable performance proven in thousands of applications worldwide
  • Certified alternative fuels including Hydrotreated Vegetable Oil (HVO), Renewable Diesel (RD) and Hydrotreated Renewable Diesel (HRD) which meet EN 15940 or ASTM D975 can be used or blended with EN 590 diesel
Cat Generator Set Package
  • Accepts 100% block load in one step
  • Meets NFPA 110 loading requirements
  • Conforms to ISO 8528-5 G3 load acceptance requirements
  • Reliability verified through torsional vibration, fuel consumption, oil consumption, transient performance, and endurance testing
Alternators
  • Superior motor starting capability minimizes need for oversizing generator
  • Designed to match performance and output characteristics of Cat diesel engines
Cooling System
  • Cooling systems are available to operate in ambient temperatures up to 50°C (122°F)
  • Tested to ensure proper generator set cooling
EMCP 4 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Warranty
  • 24 months/1000-hour warranty for Standby and Mission Critical ratings
  • 12 months/unlimited hour warranty for Prime and Continuous ratings
  • 12 months/unlimited hour warranty for Prime-DCP ratings
  • Extended service protection is available to provide extended coverage options
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Financing
  • Caterpillar offers an array of financial products to help you succeed through financial service excellence
  • Options include loans, finance lease, operating lease, working capital, and revolving line of credit
  • Contact your local Cat dealer for availability in your region
Generator Set Specifications
Standby Rating1625/1600/1500 kVA
Prime Power Rating1500/1360 kVA
Emissions/Fuel StrategyLow Fuel , Low Emissions
Voltage400 to 415 Volts
Frequency50 Hz
Speed1500 rpm
Duty CycleStandby, Mission Critical, Prime, Continuous
Minimum Rating1360 kVA
Maximum Rating1625 kVA
Engine Specifications
Engine Model3512B TA, V-12, 4-Stroke Water-Cooled Diesel
Bore6.69in
Stroke7.48in
Displacement3161.03in³
Compression Ratio14.0:1
AspirationTA
Fuel SystemElectronic Unit Injection
Governor TypeADEM™ A3
Generator Set Dimensions
Length - Minimum212.8in
Length - Maximum217.1in
Width - Minimum90in
Width - Maximum90in
Height - Minimum94.9in
Height - Maximum94.9in
Dry Weight - Genset (minimum)25620lb
Dry Weight - Genset (maximum)26530lb
Standard Equipment

Governing System

  • ADEM III

Control System

  • Digital indication for:
  • Lamp test
  • Emergency stop
  • Auto/start/stop control
  • Overspeed
  • Low oil pressure
  • Engine cycle crank
  • Low coolant level
  • Frequency (Hz)
  • 4 Programmable digital inputs
  • Operating hours
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Communications
  • Oil pressure
  • Speed adjust
  • DC volts
  • High coolant temperature
  • Coolant temperature
  • Amps (per phase & average)
  • Engine cool-down timer
  • RPM
  • EMCP 4.2B
  • Failure to start (overcrank)
  • Volts (L-L & L-N)
  • 4 Programmable digital outputs
  • Alarm acknowledge
  • Warnings/shutdown indicators
  • Emergency stop pushbutton
  • 24 Volt DC operation

Cooling System

  • Coolant level sensors
  • SCAC
  • Radiator fan and fan drive
  • Caterpillar extended life coolant
  • Coolant drain line with valve
  • Fan and belt guards

Exhaust System

  • Flanged faced outlet(s)
  • Dry exhaust manifold

Fuel System

  • Flexible fuel lines
  • Fuel priming pump
  • Secondary fuel filters.
  • Fuel cooler; not included with packages without radiator

Generator System

  • Min / max exciter
  • Caterpillar's digital voltage regulator (CDVR)
  • Class H temperature rise at 40C ambient
  • Busbar connections
  • Winding temperature detectors
  • RFI suppression
  • 3 Phase voltage sensing
  • Internal excitation (IE)
  • Random wound
  • 3 phase brushless, Salient pole
  • 6 Leads
  • NEMA Class H insulation

Literature

  • Parts book
  • Operation & Maintenance Manual

Lube System

  • Gear type lube oil pump
  • Oil filter, filler and dipstick
  • Fumes disposal
  • Oil drain lines and valve
  • Lubricating oil
  • Integral lube Oil cooler

Mounting System

  • Rails - Engine/generator/radiator mounting

General

  • RH service
  • Flywheel and Flywheel housing-SAE
  • Caterpillar yellow with high gloss black rails & radiator
  • SAE standard rotation
Optional Equipment

Air Inlet System

  • Heavy duty air cleaner
  • Dual element air cleaner
  • Single element filter

Exhaust

  • Exhaust mufflers

Generator

  • Internal excitation (IE)
  • Oversize and premium generators
  • Permanent magnet excitation (PMG)
  • Anti-condensation heater

Control System

  • Generator temperature monitoring
  • Neutral to ground connection
  • Local annunciator modules (Low voltage)
  • EMCP 4.3, EMCP 4.4
  • Cat connect: Ethernet telematics / Satellite telematics / Cell telematics
  • Annunciator modules (Local and remote)
  • Load share module options (LV)
  • CAN2 network equipment
  • Governors (MUI-Low voltage)
  • Customer interface options
  • Annunciator network equipment
  • Remote annunciator module (Low voltage)
  • EMCP voltage and current sensing groups

Power Termination

  • Circuit breakers, UL listed
  • Circuit breakers, IEC compliant

Cooling System

  • Installed radiators
  • Cooling system attachments
  • Water level switch gauges
  • Coolant

Mounting

  • Rubber anti-vibration mounts
  • IBC isolators
  • Spring type vibration isolators

Starting/Charging

  • Charging alternator
  • Heavy duty starting system
  • Oversize batteries
  • Air starting motor with control and silencer
  • Jacket water heater
  • Battery chargers

Exhaust System

  • Y Adapters
  • Mufflers
  • Flexible fittings
  • Flange and exhaust expanders
  • Elbows

Factory Support

  • Factory commissioning

Fuel System

  • Primary fuel filter
  • Secondary fuel filters

Generators and Attachments

  • Low voltage generators 380, 400, 415 Volts 3 Phase, 1500 rpm
  • Space heater kit
  • 1400 and 1600 Frame
  • Pitch 0.6667
  • 6 Leads
  • Internally excitation
  • Generator conversion kits - PM to IE / IE to PM
  • Permanent magnet excitation (PMG)
  • RW

General

  • UL 2200 package
  • The following options are based on regional and product configuration:
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • EU Certificate of Conformance (CE)

Instrumentation

  • Pyrometer and thermocouples

Lube System

  • Drain GP oil pan
  • Lube oil filters
  • Oil level regulator
  • Standard sump oil pan
  • Lube oil in standard sump
  • Prelube pump groups

Crankcase System

  • Crankcase protection group
  • Crankcase ventilation system

Mounting System

  • Low efficiency isolators
  • Spring type vibration isolators
  • Low efficiency isolators puck
  • Low isolators

Power Connections

  • Low voltage - Package mounted circuit breakers
  • Electrically operated circuit breakers
  • Low voltage - 1400 and 1600 Frame generators
  • Low voltage - Power connection options

Special Tests / Reports

  • Standard generator TVA report
  • Standard engine test charge
  • Generator test report
  • PGS Test report @ 1.0 power factor
  • Custom generator TVA report
  • Generator fuel consumption test
  • PGS Test report @ 0.8 power factor

Starting / Charging System

  • Batteries, racks and cables
  • 10 Amp Battery charger
  • Starter cover
  • Electric starting motors
  • Jacket water heaters
  • 20 Amp Battery charger
  • Jacket water heater wiring groups
  • 35 Amp Battery charger

Extended Service Coverage

  • Silver - 36 ,48, 60, 120 month coverage
  • Gold - 36,48, 60, 120 month coverage
  • Cat branded commercial power system
  • Platinum - 24, 36, 48, 60, 120 month coverage

Cat Switchgear

›
Cat Switchgear
ConfigurationIP4X
Operating Temperature35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)
Standard Widths600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.