3512B (50 Hz) with Upgradeable Package 1600-1875 kVA

3512B Diesel Generator Set

THE RUNDOWN

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
EMCP 4 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • EU Declaration of Conformity
  • EU Declaration of Incorporation
  • Eurasian Conformity (EAC)
  • Telecommunication Lab of China
One Safe Source
  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
World Wide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Cat® Diesel Engine
  • Rugged, durable design with reliable performance proven in thousands of applications worldwide
  • Certified alternative fuels including Hydrotreated Vegetable Oil (HVO), Renewable Diesel (RD) and Hydrotreated Renewable Diesel (HRD) which meet EN 15940 or ASTM D975 can be used or blended with EN 590 diesel
Cat Generator Set Package
  • Accepts 100% block load in one step
  • Meets NFPA 110 loading requirements
  • Conforms to ISO 8528-5 G3 load acceptance requirements
  • Reliability verified through torsional vibration, fuel consumption, oil consumption, transient performance, and endurance testing
Alternators
  • Superior motor starting capability minimizes need for oversizing generator
  • Designed to match performance and output characteristics of Cat diesel engines
Cooling System
  • Cooling systems are available to operate in ambient temperatures up to 50°C (122°F)
  • Tested to ensure proper generator set cooling
EMCP 4 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Warranty
  • 24 months/1000-hour warranty for Standby and Mission Critical ratings
  • 12 months/unlimited hour warranty for Prime and Continuous ratings
  • Extended service protection is available to provide extended coverage options
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Financing
  • Caterpillar offers an array of financial products to help you succeed through financial service excellence
  • Options include loans, finance lease, operating lease, working capital, and revolving line of credit
  • Contact your local Cat dealer for availability in your region
Generator Set Specifications
Standby Rating1875/1750 kVA
Prime Power Rating1700/1600 kVA
Emissions/Fuel StrategyLow Fuel , Low Emissions
Voltage400 to 415 Volts
Frequency50 Hz
Speed1500 rpm
Duty CycleStandby, Mission Critical, Prime, Continuous
Minimum Rating1600 kVA
Maximum Rating1875 kVA
Engine Specifications
Engine Model3512B TA, V-12, 4-Stroke Water-Cooled Diesel
Bore6.69in
Stroke7.48in
Stroke - HD8.46in
Displacement3161.03in³
Displacement - HD3576in³
Compression Ratio15.5:1 HD
AspirationTA
Fuel SystemElectronic Unit Injection
Governor TypeADEM™ A3
Generator Set Dimensions
Length - Minimum212.8in
Length - Maximum217.1in
Width - Minimum90in
Width - Maximum90in
Height - Minimum94.9in
Height - Maximum94.9in
Dry Weight - Genset (minimum)25620lb
Dry Weight - Genset (maximum)26530lb
Standard Equipment

Governing System

  • ADEM III

Control System

  • Auto/start/stop control
  • 4 Programmable digital inputs
  • DC volts
  • Engine cycle crank
  • Low coolant level
  • Speed adjust
  • Low oil pressure
  • Communications
  • Frequency (Hz)
  • Warnings/shutdown indicators
  • Engine cool-down timer
  • Operating hours
  • Emergency stop
  • Oil pressure
  • Lamp test
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Digital indication for:
  • Overspeed
  • Alarm acknowledge
  • RPM
  • 24 Volt DC operation
  • Amps (per phase & average)
  • Coolant temperature
  • Volts (L-L & L-N)
  • EMCP 4.2B
  • Emergency stop pushbutton
  • Failure to start (overcrank)
  • High coolant temperature
  • 4 Programmable digital outputs

Cooling System

  • SCAC
  • Coolant drain line with valve
  • Radiator fan and fan drive
  • Fan and belt guards
  • Coolant level sensors
  • Caterpillar extended life coolant

Exhaust System

  • Dry exhaust manifold
  • Flanged faced outlet(s)

Fuel System

  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines
  • Secondary fuel filters.
  • Fuel priming pump

Generator System

  • RFI suppression
  • Min / max exciter
  • 3 phase brushless, Salient pole
  • Caterpillar's digital voltage regulator (CDVR)
  • Class H temperature rise at 40C ambient
  • Random wound
  • Winding temperature detectors
  • Internal excitation (IE)
  • 3 Phase voltage sensing
  • Busbar connections
  • 6 Leads
  • NEMA Class H insulation

Literature

  • Parts book
  • Operation & Maintenance Manual

Lube System

  • Lubricating oil
  • Gear type lube oil pump
  • Fumes disposal
  • Oil drain lines and valve
  • Oil filter, filler and dipstick
  • Integral lube Oil cooler

Mounting System

  • Rails - Engine/generator/radiator mounting

General

  • Flywheel and Flywheel housing-SAE
  • Caterpillar yellow with high gloss black rails & radiator
  • RH service
  • SAE standard rotation
Optional Equipment

Air Inlet System

  • Dual element air cleaner
  • Single element filter
  • Heavy duty air cleaner

Exhaust

  • Exhaust mufflers

Generator

  • Internal excitation (IE)
  • Oversize and premium generators
  • Anti-condensation heater
  • Permanent magnet excitation (PMG)

Control System

  • EMCP voltage and current sensing groups
  • CAN2 network equipment
  • Annunciator modules (Local and remote)
  • Customer interface options
  • Load share module options (LV)
  • EMCP 4.3, EMCP 4.4
  • Annunciator network equipment
  • Neutral to ground connection
  • Generator temperature monitoring
  • Remote annunciator module (Low voltage)
  • Local annunciator modules (Low voltage)
  • Cat connect: Ethernet telematics / Satellite telematics / Cell telematics
  • Governors (MUI-Low voltage)

Power Termination

  • Circuit breakers, IEC compliant
  • Circuit breakers, UL listed

Cooling System

  • Installed radiators
  • Coolant
  • Water level switch gauges
  • Cooling system attachments

Mounting

  • IBC isolators
  • Rubber anti-vibration mounts
  • Spring type vibration isolators

Starting/Charging

  • Jacket water heater
  • Oversize batteries
  • Battery chargers
  • Charging alternator
  • Heavy duty starting system
  • Air starting motor with control and silencer

Exhaust System

  • Flexible fittings
  • Mufflers
  • Y Adapters
  • Elbows
  • Flange and exhaust expanders

Factory Support

  • Factory commissioning

Fuel System

  • Secondary fuel filters
  • Primary fuel filter

Generators and Attachments

  • Internally excitation
  • Permanent magnet excitation (PMG)
  • RW
  • 6 Leads
  • Space heater kit
  • 1400 and 1600 Frame
  • Pitch 0.6667
  • Low voltage generators 380, 400, 415 Volts 3 Phase, 1500 rpm
  • Generator conversion kits - PM to IE / IE to PM

General

  • EU Certificate of Conformance (CE)
  • The following options are based on regional and product configuration:
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • UL 2200 package

Instrumentation

  • Pyrometer and thermocouples

Lube System

  • Lube oil in standard sump
  • Standard sump oil pan
  • Lube oil filters
  • Drain GP oil pan
  • Oil level regulator
  • Prelube pump groups

Crankcase System

  • Crankcase protection group
  • Crankcase ventilation system

Mounting System

  • Low efficiency isolators
  • Low efficiency isolators puck
  • Low isolators
  • Spring type vibration isolators

Power Connections

  • Low voltage - Power connection options
  • Electrically operated circuit breakers
  • Low voltage - Package mounted circuit breakers
  • Low voltage - 1400 and 1600 Frame generators

Special Tests / Reports

  • Custom generator TVA report
  • PGS Test report @ 1.0 power factor
  • Generator fuel consumption test
  • Standard generator TVA report
  • PGS Test report @ 0.8 power factor
  • Generator test report
  • Standard engine test charge

Starting / Charging System

  • 20 Amp Battery charger
  • 10 Amp Battery charger
  • Electric starting motors
  • Starter cover
  • Batteries, racks and cables
  • Jacket water heater wiring groups
  • Jacket water heaters
  • 35 Amp Battery charger

Extended Service Coverage

  • Gold - 36,48, 60, 120 month coverage
  • Cat branded commercial power system
  • Silver - 36 ,48, 60, 120 month coverage
  • Platinum - 24, 36, 48, 60, 120 month coverage