3512 (50 Hz)

3512 Generator Set

THE RUNDOWN

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
EMCP 4 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • Telecom Lab of China (TLC)
  • EU Declaration of Conformity
  • EU Declaration of Incorporation
  • Eurasian Conformity
One Safe Source
  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Cat® Diesel Engine
  • Rugged, durable design with reliable performance proven in thousands of applications worldwide
  • Certified alternative fuels including Hydrotreated Vegetable Oil (HVO), Renewable Diesel (RD) and Hydrotreated Renewable Diesel (HRD) which meet EN 15940 or ASTM D975 can be used or blended with EN 590 diesel
Cat Generator Set Package
  • Accepts 100% block load in one step
  • Meets NFPA 110 loading requirements
  • Conforms to ISO 8528-5 G3 load acceptance requirements
  • Reliability verified through torsional vibration, fuel consumption, oil consumption, transient performance, and endurance testing
Alternators
  • Superior motor starting capability minimizes need for oversizing generator
  • Designed to match performance and output characteristics of Cat diesel engines
Cooling System
  • Cooling systems are available to operate in ambient temperatures up to 50°C (122°F)
  • Tested to ensure proper generator set cooling
EMCP 4 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Warranty
  • 24 months/1000-hour warranty for Standby and Mission Critical ratings
  • 12 months/unlimited hour warranty for Prime and Continuous ratings
  • 12 months/unlimited hour warranty for Prime-DCP ratings
  • Extended service protection is available to provide extended coverage options
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Financing
  • Caterpillar offers an array of financial products to help you succeed through financial service excellence
  • Options include loans, finance lease, operating lease, working capital, and revolving line of credit
  • Contact your local Cat dealer for availability in your region
Generator Set Specifications
Standby Rating1400/1250 kVA
Prime Power Rating1275/1150 kVA
Emissions/Fuel StrategyLow Fuel Consumption
Voltage380 to 415 Volts
Frequency50 Hz
Speed1500 rpm
Duty CycleStandby, Mission Critical, Prime, Continuous
Maximum Rating1400 kVA
Minimum Rating1000 kVA
Engine Specifications
Engine Model3512 TA, V-12, 4-Stroke Water-Cooled Diesel
Bore6.69in
Stroke7.48in
Displacement3161.03in³
Compression Ratio13.5:1
AspirationTA
Fuel SystemDirect Unit Injection
Governor TypeWoodward
Generator Set Dimensions
Length - Minimum218.8in
Length - Maximum222.9in
Width - Minimum77.8in
Width - Maximum78.1in
Height - Minimum90.7in
Height - Maximum93.2in
Dry Weight - Genset (minimum)22650lb
Dry Weight - Genset (maximum)23678lb
Standard Equipment

Air Inlet System

  • Air cleaner; single element canister type with service indicator

Control Panel

  • EMCP4.2B controls includes: Emergency stop pushbutton
  • RPM
  • Engine cool-down timer
  • EMCP4.2B controller includes:
  • Accessory module data link
  • 4 programmable relay outputs (Form A)
  • Communications:
  • Volts (L-L & L-N)
  • Over/under frequency (81 o / u)
  • Text alarm/event descriptions
  • Auto/start/stop control
  • Speed adjust
  • kVA (per phase, average & percent)
  • Overcurrent (50 / 51)
  • Alarm acknowledge
  • Environmental sealed front face
  • 6 programmable digital inputs
  • Oil pressure (psi, kPa or bar)
  • Amps (per phase & average)
  • Generator phase sequence
  • 2 Programmable digital outputs
  • Low coolant temperature
  • Controls:
  • Serial annunciator module data link
  • Reverse power (kW) (32)
  • Lamp test
  • Coolant temperature
  • Engine cycle crank
  • kVAr-hr (total)
  • 2 Programmable relay outputs (Form C)
  • Generator mounted - rear facing
  • 24 Volt DC operation
  • kVAr (per phase, average & percent)
  • Warning/shutdown with common LED indication of shutdowns for:
  • kW (per phase, average & percent)
  • Reverse reactive power (kVAr) (32RV)
  • Programmable protective relaying functions:
  • Digital indication for:
  • High coolant temperature
  • Low oil pressure
  • Overspeed
  • Over/under voltage (27 / 59)
  • Customer data link (Modbus RTU)
  • DC volts
  • Operating hours
  • Low coolant level
  • kW-hr (total)
  • Frequency (Hz)
  • Emergency stop
  • Power factor (per phase & average)
  • Failure to start (overcrank)
  • True RMS AC metering, 3-phase, +/-2% accuracy

Cooling System

  • JWAC
  • Caterpillar extended life coolant. (Not included with packages without radiator, installed SF44CTS, shipped loose radiators or heat exchangers)
  • Radiator fan and fan drive
  • Fan and belt guards
  • Coolant drain line with valve
  • Coolant level sensors (Not included with packages without radiator)

Exhaust System

  • Dry exhaust manifold
  • Flanged faced outlet(s)

Fuel System

  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines - shipped loose
  • Fuel priming pump
  • Secondary fuel filters

Generators and Attachments

  • Generator set packages include: Regulator (CDVR)
  • 6 Lead
  • Min / max exciter limiter
  • LV
  • Reactive droop capability
  • Random wound
  • Exciter diode monitor
  • KVAR/PF modes
  • NEMA Class H insulation
  • 50 Hz models: IEC standard hole pattern
  • Caterpillar's digital voltage regulator (CDVR) includes:
  • Note: 1800 Frames are form wound, permanent magnet excitation (PMG), with winding temp detectors
  • Busbar connections, top center mounted, top cable entry
  • Internal excitation (IE)
  • Winding temperature detectors
  • Class H temperature rise at 40C ambient (125C prime/150C standby)
  • 3 Phase brushless, Salient pole
  • 3 Phase voltage sensing
  • RFI suppression

Governing System

  • Woodward 2301A isochronous governor

Lube System

  • Oil drain lines and valve
  • Gear type lube oil pump
  • Fumes disposal
  • Oil filter, filler and dipstick
  • Lubricating oil
  • Integral lube Oil cooler

Mounting System

  • Rubber anti-vibration mounts - shipped loose
  • Rails - engine/generator/radiator mounting

Starting / Charging System

  • 24 Volt electric starting motor
  • Battery and battery rack w/cables
  • Battery disconnect switch

General

  • Paint - Caterpillar yellow with high gloss black rails & radiator
  • SAE standard rotation
  • RH service
  • Flywheel and Flywheel housing - SAE No. 00
Optional Equipment

Air Inlet System

  • Remote air inlet adaptors
  • Air inlet protection
  • Dual element air cleaners

Circuit breakers

  • EMAX Circuit breakers
  • Center posts busbars
  • EMAX breakers connections
  • Breaker harnesses
  • 2000, 2500, 3200 and 4000 Amp, 4 pole, IEC rated Circuit breakers
  • Controls packaging - Enclosures
  • Cable entry options
  • 2000, 2500, 3200 and 4000 Amp, 3 pole, IEC rated Circuit breakers
  • Optional busbar power connections
  • Busbar connections

Control Panel

  • Auxiliary boxes
  • Customer connection mounting locations
  • Ground (Automatically selected)
  • Vandle proof panel door
  • Customer Interface options
  • Mounting group - External box clips
  • Remote speed adjust
  • Generator temperature monitoring
  • Governors
  • Annunciator Modules
  • Local PC monitoring

Cooling System

  • Water level switch gauges
  • Heat exchangers
  • Optional radiator arrangements

European Certifications

  • EU Declaration of Conformity
  • Eurasian Conformity (EAC) mark
  • European Directive genset, DoI (Declaration of Incorporation)
  • European Union Certification

Exhaust System

  • Through-wall installation kit
  • Muffler mounting kits
  • Mufflers
  • Flexible fittings

Fuel System

  • Primary fuel filter

Generators and Attachments

  • 380 / 400 / 415 Volts @ 50 Hz, 3 phase, Form wound, Permanent magnet excitation (PMG), No. of leads = 6, pitch= 0.6667
  • 380/400/415volts @ 50 Hz, 3 phase, random wound, Permanent magnet excitation (PMG), No. of leads = 6, pitch= 0.6667
  • Generator conversion
  • 380/400/415volts @ 50 Hz, 3 phase, random wound, Internal excitation (IE), No. of leads = 6, pitch= 0.6667
  • Space heater

Instrumentation

  • Pyrometer and thermocouples

Lube System

  • Electric prelube pumps
  • Oil level reg-1 shallow pan
  • Manual prelube sump pumps

Mounting System

  • Spring type vibration isolators
  • IBC vibration isolators

Protection System

  • Explosion relief valves

Special Tests / Reports

  • Neutral grounding connection
  • IBC seismic Certifications
  • Neutral ground-LV
  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8 power factor

Starting / Charging Systems

  • Ether starting aid
  • 24 Volt dual electric starting motor
  • 20 Amp Battery charger
  • Oversize battery set
  • Jacket water heaters
  • 10 Amp Battery chargers

General

  • Engine barring group

Cat Switchgear

›
Cat Switchgear
ConfigurationIP4X
Operating Temperature35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)
Standard Widths600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.