Gas Generator CG132B-16
THE RUNDOWN
Lower Operating Costs
- Optimized engine components mean the CG132 uses up to 50% less lubricating oil than competing generator sets, which means more money stays in your company's pockets
Smaller footprint
- The CG132 uses nearly 50% less space than similar system
- Less space means lower installation costs
Cat Total Electronic Management System
- Temperature and pressure monitoring for each cylinder
- Anti-knock control allow for maximum power output and the best possible fuel utilization, even if gas composition changes
Flexible Fuel Usage
- Our gas-mixer technology and Total Electronic Management System let you use a wide variety of gases, including problematic gases like digester, landfill and sewage gases
Generator Set Specifications
| Continuous Rating | 800 kW @1.0pf |
| Fuel Type | Natural Gas, Biogas, Hydrogen Blend (up to 25%) |
| Maximum Electrical Efficiency | 43.5% / 42.6% |
| Maximum Standby Rating | 800 kW |
| Frequency | 50 / 60 Hz |
| RPM | 1500 / 1800 rpm |
Engine Specifications
| Engine Model | CG132 |
| Displacement | 2135.8in³ |
| Aspiration | TA |
| Bore | 5.2in |
| Stroke | 6.3in |
Generator Set Dimensions
| Length | 165in |
| Width | 70in |
| Height | 85in |
| Dry Weight - Genset | 17691lb |
Standard Equipment
Air Inlet
- Turbocharger with a water-cooled bearing case for all cylinder
- One-element single-stage air cleaner with enclosure and sevice indicator
Control Panels
- TPEM (Total Plant & Energy Management System)
Cooling
- Flange connections for JW inlet and outlet
- Jacket water and SCAC thermostats
- Electrical jacket water and aftercooler coolant pump
- flange connections for JW inlet and outlet
- ANSI/DN customer flange connections for JW inlet and outlet
- Cat flanges on SCAC circuit
Exhaust
- Exhaust waste gate for the CG132B-16
- Closed crankcase ventilation system
- PEARL/Low resistence exhaust system
Fuel system
- Electronic fuel metering valve
- Independently controlled cylinder monitoring and ignition system
- Pre-chamber spark plugs
Generator
- grid code generator
- Reactive droop
- closed-coupled generator result in no torque transmission to the base frame
- Busbar connections
- Anti-condensation space heater
- 3-phase sensing and KVAR/PF control
- Winding temperature detectors
Starting/Charging
- 24V starting motors
- Battery disconnect switch
General
- Crankshaft vibration damper and guard
Optional Equipment
Air Inlet
- Air cleaner with precleaner
- Mounting stand
Cooling
- CHP skid
Grid Code Compliance
- 50Hz: Germany, Belgium, Great Britain, Italy, Poland, and Netherlands