CG260-12

CG260 Gas Generator Set

THE RUNDOWN

High Reliability
  • Anti-knock control and cylinder balancing protect the engine from overload and ensure reliable operation
  • State-of-the-art turbocharger A140 with Wastegate ensures full performance even under high temperatures and higher altitudes
  • Higher reliability and lower maintenance costs due to open combustion chamber technology
High Availability, High Profitability
  • Miller valve timing and optimized compression ratios ensure high efficiency and low fuels costs
  • More profit for your plant
  • Long maintenance intervals and general overhaul only after 80,000 oh allow an operation of 10 years without general overhaul
  • Flexible fields of application also with fluctuating gas qualities due to Total Electronic Management (TEM)
Optimized Lubrication Consumption
  • Savings of up to 4,000 liters of lube oil per year compared to comparable gensets
  • Improved components reduce lube oil consumption
  • Lower operating costs due to 30% lower lube oil consumption in comparison to similar products
Generator Set Specifications
Continuous Rating3333 / 3000 ekW @1.0pf
Fuel TypeNatural Gas, Coal Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency43.90%
Frequency50Hz / 60 Hz
RPM1000 / 900 rpm
Engine Specifications
Engine ModelCG260-12
Displacement12443in³
AspirationTA
Bore10.2in
Stroke12.6in
Generator Set Dimensions
Length315in
Width105in
Height110in
Dry Weight - Genset89617lb
Standard Equipment

Air Inlet

  • One-element single-stage air cleaner with enclosure and sevice indicator
  • Turbocharger with a water-cooled bearing case for all cylinder

Control Panels

  • TEM (Total Electronic Management)

Cooling

  • flange connections for JW inlet and outlet
  • Jacket water and SCAC thermostats
  • Electrical jacket water and aftercooler coolant pump

Exhaust

  • Exhaust waste gate for the CG260-12
  • Closed crankcase ventilation system

Fuel system

  • Independently controlled cylinder monitoring and ignition system
  • Electronic fuel metering valve
  • Pre-chamber spark plugs

Generator

  • Busbar connections
  • Closed-coupled generator result in no torque transmission to the base frame
  • Anti-condensation space heater
  • Reactive droop
  • 3-phase sensing and KVAR/PF control
  • Grid code generator
  • Winding temperature detectors

Starting/Charging

  • Compressed air engine start

General

  • Crankshaft vibration damper and guard
Optional Equipment

Cooling

  • CHP skid

Grid Code Compliance

  • 50Hz: Germany, Belgium, Great Britain, Italy, Poland, and Netherlands