3516B (50 Hz) with Upgradeable Package

3516B Generator Set

THE RUNDOWN

Cat Generator Set Package
Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
SR5 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
EMCP 4 Control Panel
EMCP 4 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
Cooling System
  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
Certifications
  • EU Declaration of Conformity
  • EU Declaration of Incorporation
  • Eurasian Conformity (EAC)
  • Telecommunication Lab of China
One Safe Source
One Safe Source
  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
World Wide Product Support
World Wide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Generator Set Specifications
Standby Rating2250 kVA
Prime Power Rating2000 kVA
Emissions/Fuel StrategyLow fuel, Low Emissions
Voltage380 to 11000 Volts
Frequency50 Hz
Speed1500 rpm
Duty CycleStandby, Mission Critical, Prime, Continuous
Maximum Rating2250 kVA
Minimum Rating1750 kVA
Engine Specifications
Engine Model3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Bore6.69in
Stroke7.48in
Displacement4210.64in
Compression Ratio14.0:1 Std
AspirationTA
Fuel SystemElectronic unit injection
Governor TypeAdem™3
Generator Set Dimensions
Length - Maximum234.5in
Width - Maximum90in
Height - Maximum98.2in
Dry Weight - Genset (maximum)34460lb
Standard Equipment

Air Inlet System

  • Air cleaner; single element canister type

Control Panels

  • Auto/start/stop control
  • Engine cool-down timer
  • Environmental sealed front face
  • Emergency stop pushbutton
  • Text alarm/event descriptions
  • 24 Volt DC operation
  • Controls:
  • Generator mounted - Rear facing
  • IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min / max exciter.
  • Limiter and exciter diode monitor
  • Generator set packages include Caterpillar's voltage regulator
  • EMCP 4.2B
  • Speed adjust
  • Alarm acknowledge
  • Engine cycle crank
  • Load histogram feature
  • Lamp test
  • Digital indication for:
  • Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
  • RPM
  • PLC functionality
  • Operating hours
  • Oil pressure (psi, kPa or bar)
  • Coolant temperature
  • DC volts
  • Power factor (per phase & average)
  • Volts (L-L & L-N)
  • kW (per phase, average & percent)
  • Amps (per phase & average)
  • Frequency (Hz)
  • kVA (per phase, average & percent)
  • kVAr (per phase, average & percent)
  • Low oil pressure - High coolant temperature
  • kVAr-hr (total)
  • High coolant temperature
  • Warning/shutdown with common LED indication of shutdowns for:
  • kW-hr (total)
  • Overspeed
  • Low coolant temperature
  • Failure to start (overcrank)
  • Emergency stop
  • Over/under voltage (27 / 59)
  • Generator phase sequence
  • Low coolant level
  • Programmable protective relaying functions:
  • 6 Customer programmable digital inputs
  • Over/under frequency (81 o/u)
  • Reverse reactive power (kVAr) (32RV)
  • Serial annunciator module data link
  • Reverse power (kW) (32)
  • Number of I/O varies on options selected
  • Overcurrent (50 / 51)
  • Cat connect
  • 4 Programmable relay outputs (Form A)
  • Communications:
  • Customer data link (Modbus RTU)
  • 1 Programmable digital outputs
  • 1 Programmable relay outputs (Form C)
  • Accessory module data link
  • 3 Analog inputs

Cooling System

  • Certified standard PGS provided

Exhaust System

  • Dry exhaust manifold
  • Flanged faced outlet(s)

Fuel System

  • Fuel cooler; not included with packages without radiator
  • Secondary fuel filters
  • Fuel priming pump
  • Flexible fuel lines - shipped loose

General

  • Right hand servicing
  • SAE standard rotation
  • Flywheel and flywheel housing - SAE No. 00
  • Caterpillar yellow with high gloss black rails and radiator

Generator and Attachments

  • Busbar connections, right side extension box, bottom cable entry
  • High voltage:
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • Form wound
  • Internal excitation (IE)
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • 3 Phase brushless, Salient pole
  • Medium voltage:
  • NEMA standard hole pattern
  • Permanent magnet excitation (PMG)
  • Permanent magnet excitation (PMG)
  • Winding temperature detectors
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
  • Winding temperature detectors
  • Low voltage:
  • Form wound
  • 6 Leads  
  • Random wound
  • Anti-condensation space heater
  • Winding temperature detectors
  • Busbar connections, top center mounted, top cable entry
  • NEMA standard hole pattern

Governing System

  • ADEM A3

Literature

  • Parts book

Lubrication System

  • Integral lube oil cool
  • Lubricating oil
  • Oil filter, filler and dipstick
  • Gear type lube oil pump
  • Oil drain lines and valve
  • Fumes disposal

Mounting System

  • Rails - Engine/generator/radiator mounting
  • Rubber anti-vibration mounts - shipped loose
  • Anti-vibration mounts (shipped loose)

Starting System

  • 24 Volt electric starting motor
  • 45 Amp Charging alternator
  • Battery disconnect switch
  • Battery and battery rack w/cables
Optional Equipment

Control System

  • EMCP 4.3, EMCP 4.4
  • Controller: [ ] EMCP 4.2 [ ] EMCP 4.3 [ ] EMCP 4.4
  • Local annunciator module: [ ] NFPA 110 [ ] Custom

Air Inlet System

  • Dual element air cleaner
  • Single element filter

Engine Options

  • Air cleaner: [ ] Single element air cleaners [ ] Dual element air cleaners [ ] Heavy duty air cleaners
  • Battery charger: [ ] 10A [ ] 20A [ ] 35A
  • Starting aids: [ ] 220V 50 Hz Jacket water heater
  • Muffler: [ ] Industrial Grade
  • Starting motors: [ ] Standard [ ] Heavy duty
  • Batteries: [ ] Standard (1400 CCA) [ ] Heavy Duty (2800 CCA)

Cooling System

  • Standard ambient radiators
  • Coolant
  • Optional installed radiators
  • Optional installed ATAAC radiators
  • Water level switch gauges
  • Standard ambient ATAAC radiators

Crankcase System

  • Ventilation system
  • No explosion relief valves
  • Explosion relief valves

Exhaust System

  • Y Adapters
  • Flanges
  • Tier 4 clean emission MOD Kits
  • Clean emission parts
  • Flange and exhaust expanders
  • Flexible fittings
  • Exhaust offset
  • Mufflers
  • Tier 4 dosing cabinet
  • Tier 4 clean emissions module
  • Elbows

Alternators

  • Temperature rise (over 40°C ambient): [ ] 150°C [ ] 125°C [ ] 105°C [ ] 80°C

Power Termination

  • Power termination: [ ] Busbar [ ] Circuit breaker
  • Circuit breaker trip unit: [ ] LSI [ ] LSIG [ ] LSIG-P
  • Circuit breaker rating: [ ] 2000A [ ] 2500A [ ] 3200A [ ] 4000A

Fuel System

  • Fuel priming pumps (Tier 4) - Manual or electric
  • Primary fuel filter

Extended Service Contract (ESC)

  • Extended Service Contract (ESC): [ ] 2 Year [ ] 3 Year [ ] 5 Year

General

  • Special paint (Colors other than Caterpillar yellow or high performance paints)
  • US aid emblem

Generators and Attachments

  • Generator conversion
  • Space heater
  • Alternator air cleaner
  • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
  • Differential current transformers (DCT)
  • Differential current transformers (DCT) 8.7 kV and 15 kV classes
  • Thermostat for space heater
  • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames

Instrumentation

  • Pyrometer and thermocouples

Lubrication System

  • Oil level regulator
  • Prelube pumps
  • Lube oil in standard sump

Mounting System

  • Puck style low efficiency isolators
  • IBC vibration isolators
  • Spring type vibration isolators

Power Connections

  • Neutral ground connections
  • Center post busbars
  • Right side power connections
  • Left side power connections
  • 2700 Frame, four lead, four terminal
  • Ground cables between generator and terminal box
  • Low voltage Circuit breakers
  • Rear power connections

Special Tests / Reports

  • Torsional vibration analysis reports
  • Generator set fuel consumption test
  • PGS Test report @ 1.0 power factor
  • Fuel consumption test
  • Standard engine test charge
  • IBC Certification
  • OSHPD Certification
  • Canadian Standards Association certification
  • PGS Test report @ 0.8 power factor
  • Generator test report

Starting and Charging

  • Air pressure regulator
  • Electric starting motors
  • Starter cover
  • Jacket water heaters
  • Engine barring device
  • 24 Volt battery set - Dry
  • 10, 20, 35 and 50 Amp Battery chargers
  • Air starting motors

Extended Service Coverage

  • Platinum, Gold and Silver coverage

Cat Switchgear

Cat Switchgear
ConfigurationIP4X
Operating Temperature35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)
Standard Widths600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.