3512B (50 Hz) with Upgradeable Package 1600-1875 kVA

3512B Diesel Generator Set

THE RUNDOWN

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
EMCP 4 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • EU Declaration of Conformity
  • EU Declaration of Incorporation
  • Eurasian Conformity (EAC)
  • Telecommunication Lab of China
One Safe Source
  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
World Wide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Generator Set Specifications
Standby Rating1875/1750 kVA
Prime Power Rating1700/1600 kVA
Emissions/Fuel StrategyLow Fuel , Low Emissions
Voltage400 to 415 Volts
Frequency50 Hz
Speed1500 rpm
Duty CycleStandby, Mission Critical, Prime, Continuous
Minimum Rating1600 kVA
Maximum Rating1875 kVA
Engine Specifications
Engine Model3512B TA, V-12, 4-Stroke Water-Cooled Diesel
Bore6.69in
Stroke7.48in
Stroke - HD8.46in
Displacement3161.03in³
Displacement - HD3576in³
Compression Ratio15.5:1 HD
AspirationTA
Fuel SystemElectronic Unit Injection
Governor TypeADEM™ A3
Generator Set Dimensions
Length - Minimum212.8in
Length - Maximum217.1in
Width - Minimum90in
Width - Maximum90in
Height - Minimum94.9in
Height - Maximum94.9in
Dry Weight - Genset (minimum)25620lb
Dry Weight - Genset (maximum)26530lb
Standard Equipment

Governing System

  • ADEM III

Control System

  • Auto/start/stop control
  • 4 Programmable digital inputs
  • DC volts
  • Engine cycle crank
  • Low coolant level
  • Speed adjust
  • Low oil pressure
  • Communications
  • Frequency (Hz)
  • Warnings/shutdown indicators
  • Engine cool-down timer
  • Operating hours
  • Emergency stop
  • Oil pressure
  • Lamp test
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Digital indication for:
  • Overspeed
  • Alarm acknowledge
  • RPM
  • 24 Volt DC operation
  • Amps (per phase & average)
  • Coolant temperature
  • Volts (L-L & L-N)
  • EMCP 4.2B
  • Emergency stop pushbutton
  • Failure to start (overcrank)
  • High coolant temperature
  • 4 Programmable digital outputs

Cooling System

  • SCAC
  • Coolant drain line with valve
  • Radiator fan and fan drive
  • Fan and belt guards
  • Coolant level sensors
  • Caterpillar extended life coolant

Exhaust System

  • Dry exhaust manifold
  • Flanged faced outlet(s)

Fuel System

  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines
  • Secondary fuel filters.
  • Fuel priming pump

Generator System

  • RFI suppression
  • Min / max exciter
  • 3 phase brushless, Salient pole
  • Caterpillar's digital voltage regulator (CDVR)
  • Class H temperature rise at 40C ambient
  • Random wound
  • Winding temperature detectors
  • Internal excitation (IE)
  • 3 Phase voltage sensing
  • Busbar connections
  • 6 Leads
  • NEMA Class H insulation

Literature

  • Parts book
  • Operation & Maintenance Manual

Lube System

  • Lubricating oil
  • Gear type lube oil pump
  • Fumes disposal
  • Oil drain lines and valve
  • Oil filter, filler and dipstick
  • Integral lube Oil cooler

Mounting System

  • Rails - Engine/generator/radiator mounting

General

  • Flywheel and Flywheel housing-SAE
  • Caterpillar yellow with high gloss black rails & radiator
  • RH service
  • SAE standard rotation
Optional Equipment

Air Inlet System

  • Dual element air cleaner
  • Single element filter
  • Heavy duty air cleaner

Exhaust

  • Exhaust mufflers

Generator

  • Internal excitation (IE)
  • Oversize and premium generators
  • Anti-condensation heater
  • Permanent magnet excitation (PMG)

Control System

  • EMCP voltage and current sensing groups
  • CAN2 network equipment
  • Annunciator modules (Local and remote)
  • Customer interface options
  • Load share module options (LV)
  • EMCP 4.3, EMCP 4.4
  • Annunciator network equipment
  • Neutral to ground connection
  • Generator temperature monitoring
  • Remote annunciator module (Low voltage)
  • Local annunciator modules (Low voltage)
  • Cat connect: Ethernet telematics / Satellite telematics / Cell telematics
  • Governors (MUI-Low voltage)

Power Termination

  • Circuit breakers, IEC compliant
  • Circuit breakers, UL listed

Cooling System

  • Installed radiators
  • Coolant
  • Water level switch gauges
  • Cooling system attachments

Mounting

  • IBC isolators
  • Rubber anti-vibration mounts
  • Spring type vibration isolators

Starting/Charging

  • Jacket water heater
  • Oversize batteries
  • Battery chargers
  • Charging alternator
  • Heavy duty starting system
  • Air starting motor with control and silencer

Exhaust System

  • Flexible fittings
  • Mufflers
  • Y Adapters
  • Elbows
  • Flange and exhaust expanders

Factory Support

  • Factory commissioning

Fuel System

  • Secondary fuel filters
  • Primary fuel filter

Generators and Attachments

  • Internally excitation
  • Permanent magnet excitation (PMG)
  • RW
  • 6 Leads
  • Space heater kit
  • 1400 and 1600 Frame
  • Pitch 0.6667
  • Low voltage generators 380, 400, 415 Volts 3 Phase, 1500 rpm
  • Generator conversion kits - PM to IE / IE to PM

General

  • EU Certificate of Conformance (CE)
  • The following options are based on regional and product configuration:
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • UL 2200 package

Instrumentation

  • Pyrometer and thermocouples

Lube System

  • Lube oil in standard sump
  • Standard sump oil pan
  • Lube oil filters
  • Drain GP oil pan
  • Oil level regulator
  • Prelube pump groups

Crankcase System

  • Crankcase protection group
  • Crankcase ventilation system

Mounting System

  • Low efficiency isolators
  • Low efficiency isolators puck
  • Low isolators
  • Spring type vibration isolators

Power Connections

  • Low voltage - Power connection options
  • Electrically operated circuit breakers
  • Low voltage - Package mounted circuit breakers
  • Low voltage - 1400 and 1600 Frame generators

Special Tests / Reports

  • Custom generator TVA report
  • PGS Test report @ 1.0 power factor
  • Generator fuel consumption test
  • Standard generator TVA report
  • PGS Test report @ 0.8 power factor
  • Generator test report
  • Standard engine test charge

Starting / Charging System

  • 20 Amp Battery charger
  • 10 Amp Battery charger
  • Electric starting motors
  • Starter cover
  • Batteries, racks and cables
  • Jacket water heater wiring groups
  • Jacket water heaters
  • 35 Amp Battery charger

Extended Service Coverage

  • Gold - 36,48, 60, 120 month coverage
  • Cat branded commercial power system
  • Silver - 36 ,48, 60, 120 month coverage