3516B Generator Set

3516B Generator Set

The 3516B generator set has been developed for a wide range of applications, from emergency standby installations such as healthcare and datacenters to continuously powering remote installations. The ...
PDF Print SHARE

Generator Set Specifications

Minimum Rating
1750 kVA
Maximum Rating
2250 kVA
Voltage
400 to 11,000 Volts
Frequency
50 Hz
Speed
1500 rpm
Height - Maximum
98.2in
Length - Maximum
251in
Width - Maximum
90in
Duty Cycle
Standby, Prime, Continuous

Generator Set Configurations

Emissions/Fuel Strategy
Low Fuel Consumption, Low Emissions

Engine Specifications

Engine Model
3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Compression Ratio
14.0:1 Std
Aspiration
TA
Governor Type
Adem™3
Fuel System
Electronic unit injection
Air Inlet
Single element canister style with service indicator
Bore
6.69in
Displacement - Std
4210.64in³
Exhaust Flange Size
203.2 mm (8.0 in)
Stroke - Standard
7.48in

Standard Equipment:

Optional Equipment:

    Control System
    • EMCP 4.3, EMCP 4.4
    Air Inlet System
    • Single element filter
    • Dual element air cleaner
    Cooling System
    • Standard ambient radiators
    • Standard ambient ATAAC radiators
    • Optional installed radiators
    • Optional installed ATAAC radiators
    • Water level switch gauges
    • Coolant
    Crankcase System
    • No explosion relief valves
    • Explosion relief valves
    • Ventilation system
    Exhaust System
    • Elbows
    • Flange and exhaust expanders
    • Flanges
    • Flexible fittings
    • Y-Adapters
    • Mufflers
    • Exhaust offset
    • Tier 4 clean emissions module
    • Tier 4 dosing cabinet
    • Tier 4 clean emission MOD Kits
    • Clean emission parts
    Fuel System
    • Primary Fuel Filter
    • Fuel Priming Pumps (Tier 4) - Manual or electric
    General
    • US aid emblem
    • Special paint (Colors other than Caterpillar yellow or high performance paints)
    Generators And Attachments
    • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
    • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
    • Space heater
    • Generator conversion
    • Thermostate for space heater
    • Alternator air cleaner
    • Differential current transformers (DCT)
    • Differntial current transformers (DCT) 8.7 kV and 15 kV classes
    Instrumentation
    • Pyrometer and thermocouples
    Lubrication System
    • Lube oil in standard sump
    • Oil level regulator
    • Prelube pumps
    Mounting System
    • Puck style low efficiency isolators
    • Spring type vibration isolators
    • IBC vibration isolators
    Power Connections
    • Ground cables between generator and terminal box
    • Neutral ground connections
    • Center post busbar
    • Right side power connections
    • Left side power connections
    • Rear power connections
    • 2700 Frame, four lead, four terminal
    • Low voltage circuit breakers
    Special Tests / Reports
    • Canadian Standards Association certification
    • IBC certification
    • OSHPD certification
    • PGS test report @ 1.0 power factor
    • PGS test report @ 0.8 power factor
    • Standard engine test charge
    • generator test report
    • Fuel consumption test
    • Generator set fuel consumption test
    • Torsional vibration analysis reports
    Starting And Charging
    • Engine barring device
    • 24 Volt battery set - Dry
    • 10, 20, 35 and 50 amp battery chargers
    • Electric starting motors
    • Air starting motors
    • Starter cover
    • Air pressure regulator
    • Jacket water heaters
    Extended Service Coverage
    • Platinum, Gold and Silver coverage